Computrol Inc
Computrol is a world-class provider of mid to low volume, high-mix electronics manufacturing serv……...
Thermo Scientific* TRACE GC Ultra Gas Chromatograph is designed to be easily configured with up to two injectors and three detectors.
The Thermo Scientific TRACE GC Ultra multi-channel gas chromatograph was developed for the evolving requirements of modern laboratories. With the most complete range of proprietary inlets, sensitive detection systems, smart accessories, and ancillary devices, the Ultra platform features unique technologies that raise the standards of speed, sensitivity and separation in gas chromatography.
Features
Simple, rugged hardware
Internal LAN interfacing capability
Independently heated valve housing able to accommodate up to 4 heated/2 unheated gas valves, 8 pressure regulators, 8 needle valves, In/out ports, packed and capillary columns
Range of Large Volume techniques overcomes sensitivity boundaries of conventional GC
Linear heating rate up to 1200°C/min. reduces sample run times for crude oils, pesticides and hydrocarbons determination as well as food and flavor characterizations
High temperature programming up to 20°C/s and fast cooling times of approximately one minute
Precise retention time control
Large Volume split/splitless technique using standard splitless injector extends sample injection volume of conventional GC methods without additional investment, training or revalidation of methods
Supports range of injectors, including BEST PTV, cold on-column inlets and detector soltuions for conventional GC and GC/MS
Provides in-series, staked or parallel configurations of up to three detectors featuring different selectivity
Dedicated turnkey analyzers for chemical and petrochemical applications available
Specifications | |
---|---|
Column Oven | Programmability: 7 Ramps/8 PlateausTemperature Range: Near ambient to 450°CMaximum Temperature Ramp: 120°C/minTypical Heat-up: from 50° to 450°C in 420 secondsTypical Cool Down: 450° to 50°C in 250 secondsSub-ambient: -99°C with liquid N2, -55°C with CO2 options |
Injectors | |
Vaporizing InletsSSL, Packed, Purged PackedB.E.S.T. PTV | Temperature Range: 50° to 400°CHeating Rate: Up to 14.5°C/sec (870°C/min)Programmability: 3 ramps/4 plateausAir-cooled down to few degrees above ambient temperatureSub-ambient: -50°C with liquid N2 , -30°C with CO2 options |
Non-Vaporizing InletsCold On-column | Septumless injector. No heating of the injector is required.Suitable for manual and automated operations. Cryogenic coolant not required. |
Large Volume Options | |
Large Volume OptionsLarge Volume Cold On-column | Up to 450µL injectable volume. Uncoret type desolvation precolumn. Heated Solvent Vapor Exit valve.LVI software assistant for parameter optimization. Suitable for clean matrices. |
Large Volume B.E.S.T. PTV | Up to 450µL injection volume. Heated Solvent Split valve. Compatible with optional Backflush kit for PTV.Suitable for large volatility range samples in dirty matrices. |
Large Volume Splitless | Up to 50µL injection volume. Compatible with manual or automated injections.Suitable for samples amenable to split-splitless injector. |
Inlet Pneumatics | |
Digital (250 and 1000kPa) | Ambient Temperature and Pressure compensation. Gas saver. Assisted Leak Check Evaluation. Pressure surge.Proprietary Algorithm for Column Characterization (Linear velocity and Void Time calculation) |
Detectors | |
MDA | Flame Ionization Detector: 2 x 10-12gC/secThermal Conductivity Detector: 600pg Ethane/mL HeElectron Capture Detector: <10fg of LindaneNitrogen Phosphorus Detector: 5 x 10-14gN/s and 2 x 10-14gP/sFlame Photometric Detector: 1 x 100-13gP/s and 104 (P), 5 x 10-12gS/s (Malathion)Photo Ionization Detector: 1 x 10-12g of Benzene, 1.3 x 10-12g of ToluenePulsed Discharge Detector: Low pg range |
Linearity | Flame Ionization Detector: Better than 10cThermal Conductivity Detector: 106Electron Capture Detector: Better than 104Nitrogen Phosphorus Detector: Better than 104Flame Photometric Detector: 103 (S) after linearization with suitable softwarePhoto Ionization Detector: Better than 10cPulsed Discharge Detector: 10c |
Selectivity or Additional Features | Flame Ionization Detector: Flameout detection and timed programming capability. Acquisition rate 300HzThermal Conductivity Detector: Automated software switch functionElectron Capture Detector: 63Ni source, micro cell volume designNitrogen Phosphorus Detector: N/C = 10c:1; P/C = 2 x 10c:1Flame Photometric Detector: P/C=106:1; S/C=10c:1, Dual flame photometric capabilityPhoto Ionization Detector: Lamp cooling system for temperatures up to 400°CPulsed Discharge Detector: Non radioactive source |
Computrol is a world-class provider of mid to low volume, high-mix electronics manufacturing serv……...
The Sinar AP Moisture Analyzer is world renowned for quickly and accurately determining moisture ……...
COXEM has introduced a new scanning transmission electron microscopy (STEM) detector that provide……...
Chelsea Technologies Group Ltd operates from a 17,500 sq ft facility in Surrey, England. A team o……...
Founded in 1987 in San Diego, CA, ACCES (Acquisition Control Communication Engineering/Systems) s……...
PEREGRINE PETROLEUM, LLC, with offices in Houston and Dallas, was founded in October of 2008 by f……...
Innovative Automation, Inc delivers full service solutions for all of your manufacturing and business needs. From Process Development and Consultations to Special Systems Design, and Product Develo……
INTERGEO was founded in Salzburg in 1983. Today, with top qualified specialists, INTERGEO offers a wide range and continuously growing portfolio of services in the areas of soil and groundwater rem……
Established in 1991, the Institute of Microelectronics (IME) is a research institute under Singapore’s Agency for Science, Technology and Research (A*STAR). In IME, we focus on delivering hig……