Technical Laser services
Technical Laser Services in Rogers, Arkansas, is afabrication company founded in 1995 to provide ……...
The RM5 is a compact and fully automated Raman microscope for analytical and research purposes.The confocal design of the RM5 is one-of-a-kind to the market and offers uncompromised spatial resolution, spectral resolution, and sensitivity.
Features of the RM5 Raman Microscope
Truly confocal – With a variable slit and multiple position adjustable pinholes for higher image definition, better fluorescence rejection, and application optimization
Integrated narrowband Raman lasers – Up to three computer-controlled lasers are availablefor user-friendliness, improved stability, and decreased footprint
5-Position grating turret – For an unmatched spectral resolution of <0.3 cm-1 and optimization over the entire spectral range, from<50 cm-1 to 15,000 cm-1
Integrated detectors – Up to two integrated detectors, such as EMCCD, high-efficiency CCD, and InGaAs arrays for increased speed, low noise, high sensitivity, and extensive spectral range
Product Description
The Raman microscope buildson the expertise of strong and proven building blocks, integrated with advanced optical design considerations. It also concentrates on speed, accuracy, and function. The outcome is a modern Raman microscope that stands independently in both specifications and user-friendliness.
RM5 Raman Microscope
Video Credit: Edinburgh Instruments Ltd
Additional Features
Four-position Raman filter turret – Completely automated notch and edge filters to match the Raman range to the excitation laser wavelength
Internal standards and auto-calibration – To guarantee the highest quality data
High-performance microscope – Consistent with all the new accessories
Ramacle® software – One strong software package for full system control, data acquisition, analysis, and comfort of upgrade
Technical Specifications
Source: Edinburgh Instruments Ltd
Laser Specification | |
---|---|
Lasers | Up to 3 narrow-band lasers, including 532 nm, 638 nm, 785 nmOther wavelengths available on requestLaser selection is fully computer-controlled |
Laser Rejection Filters | Up to 3 laser rejection filters includedFilter exchange is fully computer-controlled |
Laser Attenuation | 4 orders of magnitude, continuousFully computer-controlled |
Spectrograph | ||
---|---|---|
Spectral Resolution | From <0.3 cm-1 | |
Spectral Range | <50 cm-1– 15,000 cm-1* | |
Spectrograph | TypeFocal LengthGratingsSlits | Asymmetric Czerny-Turner225 mm5-position grating turret, fully computer-controlledContinuously adjustable, fully computer-controlled |
Confocal Imaging | Adjustable confocal pinhole, fully computer-controlled |
Detectors | ||
---|---|---|
Detectors | Standard Detector | High sensitivity ultra low noise CCD1650 x 200 pixels, TE-cooled -60 °C (standard) OR2000 x 256 pixels, TE-cooled -60 °C (enhanced sensitivity and spectral range) |
Optional Second Detector | EMCCD detector, InGaAs and others available on requestSelection of detectors, fully computer-controlled |
System | ||
---|---|---|
Raman Polarisation | Optional | Polarisation kit available, fully computer-controlled |
Internal Calibration | Wavelength calibration standard (Neon)Raman shift standard (Silicon)Sensitivity validation standard (Silicon)Automated laser alignment | |
Microscope System | Functionality | Full upright microscope with brightfield and darkfield illuminatorPolarisation, Differential Interference Contrast (DIC) capability and fluorescence imaging10x and 100x objective included as standard; up to 5 can be included |
Optional Objective(s) | Trinocular eyepiece, embedded CMOS video camera, second video camera optional | |
Sample Viewing | XY manual stage | |
Sample Stage | XYZ motorized stage (75 mm x 50 mm XY), confocal Raman mapping | |
Optional | Temperature-controlled sample stages available | |
Software | Ramacle® | Comprehensive all-in-one, intuitive software package |
Operating System | Windows® | |
Functionality | Data acquisition, spectrograph control, graphical display, data processing | |
Optional | Chemometric, spectral library packages – KnowItAllTM | |
Laser Safety | Without Laser EnclosureWith Laser Enclosure | Class 3BClass 1 |
Dimensions | W x D x H †Weight † | 600 mm x 800 mm x 600 mm† 63 kg* depending on the grating, laser and CCD selection† without laser enclosure |
Technical Laser Services in Rogers, Arkansas, is afabrication company founded in 1995 to provide ……...
Research in our group is at the crossroads of electrochemistry, material science and chemical ana……...
Fujitsu Semiconductor Memory Solution offers memory products and various solutions centered on Fe……...
G & S Bar and Wire manufacturestitanium and other specialty alloysas wire andbar in varioussh……...
United Lens Company is a vertically integrated custom manufacturer of Optical Thin Film Coatings,……...
The QuasIR™ 2000E FT-NIR spectrometer available from Galaxy Scientific continuously measure……...
Archway Engineering is one of the UK’s leading manufacturers of drilling equipment for site investigation, mineral exploration, water well construction, and environmental monitoring. We manuf……
The HMK-CD5 laser particle size analyzer is a new generation of analyzers developed by Aimsizer Scientific. It is made by ISO 13320 and ISO 13321 and operates on the two most advanced theories. Pho……
VPI is a complete turnkey design, manufacturing, service, engineering, research, and installation entity, which provides custom vacuum and thermal process equipment for various industries. Our miss……