The RM5 Raman Microscope

上海仪舶实验室自动化 25-01-23 15:03:53

The RM5 Raman Microscope

The RM5 is a compact and fully automated Raman microscope for analytical and research purposes.The confocal design of the RM5 is one-of-a-kind to the market and offers uncompromised spatial resolution, spectral resolution, and sensitivity.

Features of the RM5 Raman Microscope

Truly confocal – With a variable slit and multiple position adjustable pinholes for higher image definition, better fluorescence rejection, and application optimization

Integrated narrowband Raman lasers – Up to three computer-controlled lasers are availablefor user-friendliness, improved stability, and decreased footprint

5-Position grating turret – For an unmatched spectral resolution of <0.3 cm-1 and optimization over the entire spectral range, from<50 cm-1 to 15,000 cm-1

Integrated detectors – Up to two integrated detectors, such as EMCCD, high-efficiency CCD, and InGaAs arrays for increased speed, low noise, high sensitivity, and extensive spectral range

Product Description

The Raman microscope buildson the expertise of strong and proven building blocks, integrated with advanced optical design considerations. It also concentrates on speed, accuracy, and function. The outcome is a modern Raman microscope that stands independently in both specifications and user-friendliness.

RM5 Raman Microscope

Video Credit: Edinburgh Instruments Ltd

Additional Features

Four-position Raman filter turret – Completely automated notch and edge filters to match the Raman range to the excitation laser wavelength

Internal standards and auto-calibration – To guarantee the highest quality data

High-performance microscope – Consistent with all the new accessories

Ramacle® software – One strong software package for full system control, data acquisition, analysis, and comfort of upgrade

Technical Specifications

Source: Edinburgh Instruments Ltd

Laser Specification
Lasers Up to 3 narrow-band lasers, including 532 nm, 638 nm, 785 nmOther wavelengths available on requestLaser selection is fully computer-controlled
Laser Rejection Filters Up to 3 laser rejection filters includedFilter exchange is fully computer-controlled
Laser Attenuation 4 orders of magnitude, continuousFully computer-controlled
Spectrograph
Spectral Resolution From <0.3 cm-1
Spectral Range <50 cm-1– 15,000 cm-1*
Spectrograph TypeFocal LengthGratingsSlits Asymmetric Czerny-Turner225 mm5-position grating turret, fully computer-controlledContinuously adjustable, fully computer-controlled
Confocal Imaging Adjustable confocal pinhole, fully computer-controlled
Detectors
Detectors Standard Detector High sensitivity ultra low noise CCD1650 x 200 pixels, TE-cooled -60 °C (standard) OR2000 x 256 pixels, TE-cooled -60 °C (enhanced sensitivity and spectral range)
Optional Second Detector EMCCD detector, InGaAs and others available on requestSelection of detectors, fully computer-controlled
System
Raman Polarisation Optional Polarisation kit available, fully computer-controlled
Internal Calibration Wavelength calibration standard (Neon)Raman shift standard (Silicon)Sensitivity validation standard (Silicon)Automated laser alignment
Microscope System Functionality Full upright microscope with brightfield and darkfield illuminatorPolarisation, Differential Interference Contrast (DIC) capability and fluorescence imaging10x and 100x objective included as standard; up to 5 can be included
Optional Objective(s) Trinocular eyepiece, embedded CMOS video camera, second video camera optional
Sample Viewing XY manual stage
Sample Stage XYZ motorized stage (75 mm x 50 mm XY), confocal Raman mapping
Optional Temperature-controlled sample stages available
Software Ramacle® Comprehensive all-in-one, intuitive software package
Operating System Windows®
Functionality Data acquisition, spectrograph control, graphical display, data processing
Optional Chemometric, spectral library packages – KnowItAllTM
Laser Safety Without Laser EnclosureWith Laser Enclosure Class 3BClass 1
Dimensions W x D x H †Weight † 600 mm x 800 mm x 600 mm† 63 kg* depending on the grating, laser and CCD selection† without laser enclosure
[The RM5 Raman Microscope]相关推荐
Technical Laser services

Technical Laser services

Technical Laser Services in Rogers, Arkansas, is afabrication company founded in 1995 to provide ……...

G & S Bar and Wire

G & S Bar and Wire

G & S Bar and Wire manufacturestitanium and other specialty alloysas wire andbar in varioussh……...

United Lens Co., Inc.

United Lens Co., Inc.

United Lens Company is a vertically integrated custom manufacturer of Optical Thin Film Coatings,……...

今日仪器
  1. Archway Engineering (UK) Ltd

    Archway Engineering (UK) Ltd

    Archway Engineering is one of the UK’s leading manufacturers of drilling equipment for site investigation, mineral exploration, water well construction, and environmental monitoring. We manuf……

    代理品牌 2025-07-31

  2. HMK-CD5 Laser Particle Size Analyzer

    HMK-CD5 Laser Particle Size Analyzer

    The HMK-CD5 laser particle size analyzer is a new generation of analyzers developed by Aimsizer Scientific. It is made by ISO 13320 and ISO 13321 and operates on the two most advanced theories. Pho……

    仪器产品 2025-07-31

  3. Vacuum Processes, Inc.

    Vacuum Processes, Inc.

    VPI is a complete turnkey design, manufacturing, service, engineering, research, and installation entity, which provides custom vacuum and thermal process equipment for various industries. Our miss……

    代理品牌 2025-07-31

返回顶部小火箭