Adalet
Adalet, a division of Scott Fetzer (a wholly-owned subsidiary of Berkshire Hathaway Inc.), is an ……...
The MicroCal PEAQ-DSC manual instrument provides easy-to-use, highly sensitive microcalorimetry that helps to reduce the time and cost associated with comparability analysis and stability testing. The MicroCal PEAQ-DSC is a manual instrument with a cleaning device, which can be upgraded to an automated version upon request.
The data generated by the MicroCal PEAQ-DSC provides important guidance for biopharmaceutical development in (pre)formulation development, protein engineering, manufacturing change control, process development, and biocomparability and biosimilarity studies.
The integrated software simplifies workflows, enables non-subjective data analysis, performance qualification and compliance with 21 CFR Part 11 and Annex 11 regulations, resulting in high integrity data and stimulating productivity in biopharmaceutical research.
Differential Scanning Calorimetry (DSC) is a powerful analytical tool that characterizes the thermal stability of proteins and other biomolecules. The method measures the temperature (TM) and enthalpy (ΔH) of thermally-induced structural transitions of molecules in solution.
This information provides important insights into factors that stabilize or destabilize proteins, micellar complexes, nucleic acids, and other macromolecular systems.
The data is used to estimate the shelf-life of biomolecular products including biopharmaceuticals, to develop purification strategies, to facilitate biosimilar and batch-to-batch versus innovator molecule comparisons, to characterize and assess protein constructs, and to rank the affinities of ligands to their protein targets in small molecule drug discovery programs.
The high-sensitivity MicroCal PEAQ-DSC system features automated data analysis to support the production of high integrity thermal stability data and deliver compliance with regulatory requirements, while also allowing easy integration into exisiting data handling and transfer systems.
Unattended operation of the instrument after sample loading frees up operator time. This comprehensive system does not require extra reagents, accessories, or consumables.
Key Features
The key features of the MicroCal PEAQ-DSC Manual System are as follows:
Manual system with cleaning device and pipette
Gold standard stability-indicating method requiring minimum assay development
Direct and label-free measurement of biomolecular native-state stability in solution
Measurement of very tight binding constants, up to 1020M-1
Powerful MicroCal PEAQ-DSC software reduces usual data analysis time and includes:
PEAQ-Compare: For the quantitative comparison of DSC traces for comparability studies, ideal for batch-to-batch and biosimilarity studies
PEAQ-Compliance: The system is available with Malvern Panalytical Access Controller (MAC) to limit access to user-defined SOPs and data analysis features. Data can be displayed using the Report Generator with user details and the ability to sign using electronic signatures to facilitate the integration of the workflow into your company’s quality system and aid compliance with 21 CFR Part 11 and Annex 11 regulations. This is available as an optional accessory
PEAQ-Smart (including PEAQ-Finder): For SOP-based operation and data analysis. Provides new algorithms to detect even subtle peaks and shoulders, facilitating the automatic, non-subjective identification of multiple transitions, such as those seen in multi-domain proteins
PEAQ-Performance: Automatically detects and validates system readiness for optimal performance
Network-ready: email updates sent during the analysis to keep users informed of assay progress
The MicroCal PEAQ-DSC Automated, with an autosampler, is also available.
How It Works
Functional structures produced by proteins and other macromolecules frequently undergo temperature-induced conformational alterations, such as unfolding. These alterations cause the absorption of heat due to the redistribution of non-covalent bonds within the molecule. Differential Scanning Calorimeters measure this heat uptake very precisely.
The MicroCal PEAQ-DSC system’s thermal core contains a reference cell (containing a matched buffer solution) and a sample cell (containing the sample of interest). Both cells are placed within an insulating jacket. They are constantly maintained at the same temperature, and while a measurement is performed, they are heated at a constant scan rate.
When the molecule inside the sample cell unfolds, heat is absorbed, forming a temperature difference (ΔT) between the reference cell and the sample cell. This results in a thermal gradient across the Peltier units, forming a proportional voltage, which is then converted to power to create a feedback loop to the Peltier units, in order to return ΔT to zero.
As protein unfolding is an endothermic occurrence, it is seen as a positive displacement in the thermogram. This protein ‘melting’ transition’s midpoint is the TM, and the area under the curve is the enthalpy (ΔH) of the unfolding process (refer figure below).
Specifications
General
Technology: Differential Scanning Calorimetry
Measurement type: Temperature midpoint (TM); Enthalpy (ΔH); Heat capacity change (ΔCp)
Cell
Cell: Capillary
Cell material: Tantalum
Cell volume: 130 µL
Sample
Sample volume: 250 µL (manual filling)
Typical sample concentration: 0.01 mg/mL – 10 mg/mL1
Sample throughput: ≤6 samples analyzed/8h
System
Noise: 0.05 µCal/°C 2
Baseline repeatability: 1 µCal/°C 2
Response time: 5s 2
Repeatability: <0.2 µCal/°C 3
Reproducibility: <0.08 °C St. Dev. TM and <2% RSD on ΔH 4
System reproducibility: <0.1°C St. Dev. TM and <5% RSD on ΔH 4
Multiple feedback modes: Yes (high gain, passive, and low gain)
Temperature range: 2 °C to 130 °C 2,5
Maximum scan rate: 240 °C/h
Reverse scanning: Yes
Pressure perturbation calorimetry (PPC): N/A - manual cleaning device with guided workflows
Cleaning solvents: Water and detergent (Contrad 90) used as standard
Software
21 CFR part 11: Yes, with PEAQ-Compliance software option
Network ready: Yes, with email alert capability
Software
21 CFR part 11: Yes, with PEAQ-Compliance software option
Network ready: Yes, with email alert capability
Operating Environment
Operating temperature (°C): +10 °C to +28 °C
Storage temperature: -20 °C to +50 °C
Humidity: 10% to 70%, non-condensing (10% to 90% for storage)
Ingress Protection (IP) rating: IP21Power:100-240 V A/C, 50/60 Hz, 70 W (cell), PC as supplied
Certification: CE (EN61010-1), EMC (EN61326-2-1, EN61326-1, ICES, FCC, VCCI), ISO9001:2008
Weight and dimensions
Dimensions (W, D, H): 20 cm x 44 cm x 19 cm
Weight: 8.2 kg
Notes
1 Sample dependent2 Typical results for ribonuclease (RNase) in 50 mM KAc buffer at pH 5.5, at 60 °C/h with passive feedback3 Rescans of a stable buffer4 Using ribonuclease (RNase)5 Range may be extended down to -10 °C upon request
Adalet, a division of Scott Fetzer (a wholly-owned subsidiary of Berkshire Hathaway Inc.), is an ……...
The AT2 Automated XY Stage from Instron can be integrated with any existing or new 5900 and 6800 ……...
Electron backscatter diffraction (EBSD) is a robust microanalysis method that enables rigorous ch……...
Pine Cliff Energy Ltd. is a public company actively engaged in the acquisition of interests in pe……...
D-Link has designed, developed and manufactured award-winning networking, wireless, video surveil……...
TRIDENT Environmental Group, LLC is an environmental contracting firm whose purpose is to provide……...
The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……
Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……
For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……