Hammer Union Pressure Transmitter - Model 511

上海仪舶实验室自动化 25-01-23 16:18:48

Hammer Union Pressure Transmitter - Model 511

The product features 4-20 mA output, 2" 1502 fitting, hazardous location approvals.

The 511 is Viatran's state of the art hammer union pressure transmitter comprising of industry exclusive features that were created in direct response to requests from the field. Included in these features is a voltage powered shunt cal, potential to calibrate and track pressure spikes using HART® Communicators or DevCom2000-Lite software and packaged in a patented* housing capable of withstanding extreme vibration and abusive impact and still continuing to perform to specification.

Features

RoHS compliant

High pressure applications

ShuntCal

IP-68 rated

1502 Hammer Union Pressure Fitting

Shunt calibration

Easy Access Connector Housing - 77% greater area

Expanded compensated temperature range

Enhanced sealing method for connector pins

External adjust, identification and peak pressure capture

Patented* Design capable of withstanding extreme vibration and abusive impact

Impervious to fluid ingress with patented angled connector base, drain holes, and sealing method

*EU Patent No. 002334250-001*CN Patent ZL 201330 527540.1*US Patents D711266 , US 9,607,596 B2

Performance

. .
Full Scale Pressure Ranges 0-5 K, 0-6 K, 0-10 K, 0-15 K, 0-20 K PSIS
Combined Accuracy (BFSL) (Non-Linearity, Hysteresis & Repeatability)≤ ± 0.25% FSO
Full Scale Output (FSO) 16.00 mA ±1% FSO @70 °F
Zero Balance. 4 mA ±1% FSO @70 °F
Compensated Temperature Range -40 °F to 140 °F (4 °C to 60 °C)
Operating Temperature Range -40 °F to 185 °F (-40 °C to 85 °C)
Storage Temperature Range -67 °F to 302 °F (-55 °C to 150 °C)
Long Term Stability (%FSO) ≤ ± .25% FSO per 6 months
Thermal Effect on Zero ≤± 1% FSO per 100 °F Typical
Thermal Effect on Span ≤± 1% FSO per 100 °F Typical

Electrical

. .
Output Signal 4-20 mA @70 °F
Supply Voltage 9-28 Vdc
Power Supply Regulation <± .01% FSO per volt
Load Impedance 900 ohms @ 28 VDC decreasing linearity to 0 ohms @ 9 VDC
Circuit Protection Reverse polarity protected
RFI / EMI <1% FSO output change with 3 V Rms from 150 kHz to 80 MGz(80% AM modulated at 1 kHz) applied to power supply and signal lines[IEC 61000-4-6 radio frequency common mode immunity],1% output change when exposed to a radiated electromagnetic field of 10 V/m from 80 MHz to 1 GHz AM modulated at 1 kHz and 3 V/m1.4 GHz to 2.7 GHz. [IEC 61000-4-3 Radiated electromagnetic field immunity]
Voltage Spike Protection Withstand 1000 volt spike per EN 61000-4-5
Insulation Resistance < 5 nS
Response Time < 1 millisecond to reach 90% of FSO
Range Calibration Signal 100% FSO ±10% by exciting pins E&F
Calibration Power Supply Voltage 8.5 -28 VDC
Calibration Signal Accuracy Readings on calibration certificate are within ±0.2% FSO of actual Cal signal output
Bridge Resistance 10 K ohms, nominal
Standard Electrical Connection Mates with 6 pin, Hermetic, Box Mount, Shell Size 10, MIL-C-26482 bendix type connector
PIN OUTS PIN A + Power / SignalPIN B - Power / SignalPIN C No ConnectionPIN D No ConnectionPIN E + CalibrationPIN F - Calibration

Mechanical

. .
Standard Pressure Port Male hammer union 2 inch #1502
Pressure Cavity Volume Standard: 0.45 cubic inchesOption "TP" : 0.22 cubic inches
Zero Effect from Installation 0.3% FSO w/200 ft-lbs torque on union #1502
Shock Sensitivity 1000 g, 0.5 ms half sine wave pulse shall not cause change in calibration
Proof Pressure 1.67X range or 22,500 PSI max
Burst Pressure 3 Times full scale pressure range, limited by union #1502: 22.5 K PSI

Materials of Construction

. .
Wetted Materials NACE compliant Inconel 718 (MR0175/ISO 15156-3:2009(E))
Enclosure Material 304 Stainless Steel
Identification Laser marked on body of unit
Enclosure Rating IP68*, NEMA 6P*
Weight 5.6 lbs. nominal

* Pending approvals

Options

. .
DC Compensated temperature -40 °F to 140 °F
DG Improved temperature compensation
DH Special Range
DN Improved accuracy
EA Special Calibration Run
EH Compensated temperature range 40 °F to 180 °F
LW Narrow adapter for banding
NA Carrying handle attached
NH Customer specific identification
NP Protective ring cage
NQ Protective criss-cross cage
QJ 17-4 PH wetted material, heat treated per NACE MR0175-2000
Z() Special connectors

Hammer Union Pressure Transmitter

[Hammer Union Pressure Transmitter - Model 511]相关推荐
Lloyd Instruments Ltd.

Lloyd Instruments Ltd.

Lloyd Instruments designs, manufactures and is a recognized world supplier of universal materials……...

Thatcher Co.

Thatcher Co.

Thatcher Company is a diversified chemical manufacturer and distributor.As a custom chemical manu……...

LGD in TECH

LGD in TECH

LGD in TECH is bringing together the world’s premier diamond growers and the leading compan……...

今日仪器
  1. ANGEL BIT from Quarry Mining & Construction Equipment Pty Ltd

    ANGEL BIT from Quarry Mining & Construction Equipment Pty Ltd

    The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……

    仪器产品 2025-04-28

  2. Jetcrete Australia

    Jetcrete Australia

    Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……

    代理品牌 2025-04-28

  3. Borealis AG

    Borealis AG

    For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……

    代理品牌 2025-04-28

返回顶部小火箭