With the rapid MAX N exceed, laboratories can analyze nitrogen and protein more efficiently. Designed usingthe secure, uncomplicated, and environmentally conscious Dumas combustion technique, the rapid MAX N exceed nitrogen and protein analyzer enables quick and economical determination of nitrogen and protein content, all within a five-minute timeframe.
The analyzer, which is designed for unsupervised 24/7 operation, satisfies the needs of any high-throughput laboratory dealing with a wide range of sample types and weights. The rapid MAX N exceed ensures exceptional accuracy, sensitivity, and sample flexibility, allowing users to increase thelaboratory efficiency of their nitrogen and protein analysis.
Highlights of the rapid MAX N exceed
Maximum Sample Flexibility
The upright crucible design and distinct post-combustion technology provide maximum sample flexibility for a broad range of sample matrices.
Simplified Sample Preparation
Sample preparation is simplified thanks tothe huge weighing ranges and sample volumes of up to 5 g / 5 ml.
Highest Sample Throughput
Fast analysis (5 minutes) and low maintenance allow for the highest sample throughput.
Lowest Cost per Sample
The EAS REGAINER® technology and theoption of using argon as a carrier gas results in the lowest price per sample.
Video Credit: Elementar Americas Inc.
Features
Maximum Sample Flexibility Due to Crucible Design and Unique Post-Combustion Technology
The rapid MAX N exceed’s upright crucible design allows nitrogen and protein analysis of any sample, from liquids like milk, soft drinks, beer, soy sauce, juice, and so on, to semiliquids like yogurt and mayonnaise, to solids like cereals, meat, and flour. Coupled with Elementar's post-combustion technology, complete and unmatched combustion of even challenging sample matrices is ensured.
Simplified Sample Preparation Through Largest Weighing Ranges and Sample Volumes
With a substantial 5 g / 5 ml capacity, the reusable, durable steel crucibles of the rapid MAX N exceed ensure convenient sample preparation for extensive weighing ranges and sample volumes during nitrogen and protein analysis.
Highest Sample Throughput Due to Low Maintenance and Fast Analysis
The rapid MAX N exceed provides the fastest nitrogen and protein determination in as little as five minutes. Its 90-position autosampler, which can be reloaded at any time, makes it simple to prioritize urgent samples during a measurement run.
Over 1,000 samples can be run without changing the reducing agent, thanks to the inventive EAS REGAINER® technology. Furthermore, the plug-and-play pre-filled EAS REDUCTOR® tube, which is used for reduction, saves valuable time.
As a result, nitrogen and protein analysis systems operate at industry-leading uptimes with exceptional low-maintenance intervention. The slide-out furnace and the user-friendly clamp connections system also assure tool-free maintenance and a comfortable working position.
Lowest Cost Per Sample, Thanks to EAS REGAINER® Technology and Argon as Carrier Gas
One of the most expensive aspects of traditional Dumas nitrogenandprotein analyzers is the reduction of metals required to bind excess oxygen and convert nitrogen oxides to molecular nitrogen.
However, with Elementar's patentedEAS REGAINER®technology which is integrated intothe rapid MAX N exceed, this cost can be dramatically reduced.
In continuous flow, the reducing agent EAS REDUCTOR®is regenerated during each combustion phase by the inexpensive EAS REGAINER®, enabling the analysis of up to 1,000 samples before the EAS REDUCTOR® needs to be replaced.
This, in combination with the use ofargon instead ofhelium as a carrier gas, means that the rapid MAX N exceed is able to achieve the lowest cost per sample in nitrogenandprotein analysis.
Future-Proof Thanks to 10 Years Guarantee
Due to its remarkable strength and long-lasting nature, the rapid MAX N exceed has a 10-year guarantee on the high-temperature combustion furnace and the thermal conductivity detector cell of the thermal conductivity detector (TCD).
With a long-term dedication to technical support, Elementar provides spare parts for a minimum of 10 years. This results in an outstanding low total cost of ownership, giving users confidence in their return on investment.
Product Details
Modes
The rapid MAX N exceed is streamlined for the analysis of:
Protein
Nitrogen
Dietary fiber analysis
Analytical Specifications
Maximum Sample Weight
Up to 5 g or 5 ml
Element Concentration Range
Large concentration range
N: up to 500 mg absolute, from 20 ppm to 100 %
Precision
Helium: < 0.05 % absolute (250 mg glutamic acid)
Argon: < 0.15 % absolute (250 mg glutamic acid)
Analysis Time
~ 4–5 minutes, self-optimizing according to element content and sample weight.
Technical Specifications
High-temperature combustion with 100% nitrogen recovery and detection. For nitrogen and protein analysis in accordance with current ISO, EN, DIN, AOAC, and other national and international standards.
Detector
Thermal Conductivity Detector (TCD)
Sample Introduction
Sample introduction via an integrated 90-position autosampler that can be reloaded during analysis.
Maximum Furnace Temperature
1,200 °C
Instrument Control
Windows® based rapid MAX N exceed operating software with LIMS integration and auto sleep and wake-up function for automated and unattended overnight operation. 21 CFR Part 11 functionality available (optionally).
Required Gases
Helium or Argon and Oxygen
Dimensions
63 × 55 × 106 cm (W × D × H)
Accessories
Electronic Balance
Balance and elemental analyzer form a system.With all Elementar instruments,analytical balances from leading manufacturers are offered.
Accumold began in a rented garage in 1985. Our primary focus was and still is on very small micro……...
Direct fuel dilution measurements are possible with Spectro scientific's FDM 6000, which is ……...
Multi-Lab is one of the leading High Purity Natural and Synthetic Quartz Glass distributors in Eu……...
Pump Tech Systems, distributor of Water Treatment products. We provide quality products and servi……...
Bruker BioAFM, former JPK Instruments AG, is a leading manufacturer of n……...
Founded in 1954, under the name CARL HERRMANN and ASSOCIATES, CHA Industries, is a privately held……...
The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……
Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……
For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……