SVT Schmidt Verpackungstechnik GmbH & Co KG
The company Schmidt Verpackungstechnik has been producing on the german market for 20 years.We ma……...
ZEISS Xradia CrystalCT is the cutting-edge microCT for interpreting the materials’ crystallographic and microstructural secrets. It is the first to combine the power of computed tomography with the capacity to prove crystallographic grain microstructures, revolutionizing the way in which polycrystalline materials (such as metals, additive manufacturing, ceramicsand other materials) are studied, leading to new and deeper insights into materials research.
Determine the properties of metals, alloysand ceramics
Ground-breaking diffraction scanning modes advance materials evaluation and discovery
At increased throughput, map bigger volumes and a wider range of sample shapes
Perform 3D non-destructive grain morphology mapping
To construct high-fidelity computational models, achieve higher sample representivity
Highlights
DCT for an Expanded Range of Research Possibilities
Xnovo Technology and ZEISS Research Microscopy Solutions have teamed up to bring breakthrough laboratory diffraction contrast tomography (DCT) capability to market.
DCT on a microCT, which uses 3D grain mapping, allows technical and industrial research laboratories to image single-phase polycrystalline materials in 3D, encompassing a wide range of metal, ceramic, mineral, semiconductorand pharmaceutical samples.
The ZEISS Xradia CrystalCT comprises precisely engineered aperture and beam stop components that were created specifically to harness divergent, polychromatic X-Ray beams to spotlight a region of interest and boost sensitivity to weaker diffraction signals of polycrystalline objects.
Innovative DCT collection modes eliminate sample size limits, allowing users to investigate a wider range of sample types. Scanning samples quicker and with more precise data representation is possible with seamless high-volume grain mapping.
Schematic illustration of CrystalCT projection geometry. CrystalCT delivers dual modalities: absorption contrast tomography (ACT) and diffraction contrast tomography (DCT). Image Credit: Carl Zeiss Microscopy GmbH
Superior Sample Representivity from Advanced Diffraction Scan Modes
Through ground-breaking diffraction scanning modes, ZEISS Xradia CrystalCT enhances materials characterization, modelingand discovery.
Allows for greater sample volumes to be scanned
Addresses the issue of sample specificity
Sample preparation and management of irregular/natural sample shapes are simplified
Speeds up the process
Provides unrivaled sample representativeness
These advanced modes solve some of the problems with typical DCT data collection, which assumes that the sample ROI is completely lighted by the aperture field of view (FOV) at all rotating angles. Advanced diffraction scanning modes give helical phyllotaxis schema to address a wide range of sample shapes and sizes, inspired by nature’s golden angle.
Al-4wt%Cu sample with gauge section dimension of (length) 1.25 mm, (width) 1.0 mm and (thickness) 0.5 mm. Sample scanned using helical phyllotaxis HART. Image Credit: Carl Zeiss Microscopy GmbH
A Powerful MicroCT Platform
On a microCT, ZEISS uses its robust Xradia technology to achieve world-leading performance. Users can get high-quality, high-resolution scans with best-in-class contrast using a powerful stage, flexible software-controlled source/sample/detector placement, and a huge array detector.
To expose inner elements in their complete 3D setting, capture whole items or gadgets. Faster acquisition rates allow users to control more samples in less time, boosting overall productivity and profits.
In situ and 4D investigations using non-destructive CT are also possible to determine the practical impact of changing environments over time. The ZEISS Xradia imaging system blends a tried-and-true hardware design with cutting-edge drift and stability capabilities.
CrystalCT routinely exceeds one’s understanding of what a microCT is due to the higher stability of this recognized platform.
Quantitative volumetric analysis of a steel-reinforced concrete specimen. Voids are rendered in purple. Image Credit: Carl Zeiss Microscopy GmbH
Fields of Application
ZEISS Xradia CrystalCT is a cutting-edge, dramatically new diffraction scanning technique that allows users to map grain boundary surfaces in their original condition across substantially greater volumes while targeting realistic sample shapes that meet the needs of research and industrial laboratories.
DCT allows for non-destructive 3D grain imaging, unlike previous grain mapping methods.
Material Science
Surface imaging technologies, such as optical or scanning electron microscopy, do not reveal non-destructive insights into internal microstructures or overlay grain maps
Ex situ or in situ investigations using 4D imaging to examine how materials develop, such as through mechanical load or corrosion
Ability to separate and analyze data to provide quantitative, three-dimensional representations of structures and particles
High-resolution absorption contrast tomography and non-destructive 3D grain imaging provide additional information on size, shape, orientationand grain boundary
3D grain map of aluminum-copper alloy imaged in absorption and diffraction contrast tomography. Image Credit: Carl Zeiss Microscopy GmbH
Metals andMinerals
To get knowledge into alloy performance and its influence on thermal and mechanical processes, study grain size and phase evolution in 3D
In situ flow investigations or 3D mineralogy need high contrast 3D imaging
Estimate materials properties (thermal, mechanical, etc.) or digital rock simulations utilizing non-destructive 3D tomography data imaging, characterizationand modeling of rock cores (up to 4") with high throughput
3D grain map of an ultra-thin oriented electrical steel sample with dimension of (RD) 4 mm, (TD) 2 mm and (ND) 0.08 mm. Image Credit: Carl Zeiss Microscopy GmbH
Manufacturing
Assess the print quality of 3D printed metal items using crystallography
Physical cross-sectioning can be used to supplement or replace physical cross-sectioning, removing the need to sacrifice the sample
Scanning of intact devices with high throughput and with a short time to findings
Create a range of sample sizes, including huge objects in their complete 3D environment, with 3D grain maps for specialized applications
3D grain map of polysilicon materials from a solar panel with height of 30 mm. Image Credit: Carl Zeiss Microscopy GmbH
Life Science
3D electron microscopy allows for quick, non-destructive evaluation of sample staining and feature positioning for future imaging
With high contrastimaging, either stained or unstained hard and soft tissues, as well as biological microstructures
2D virtual cross-section and a cutaway view of 3D rendering of a mouse embryo embedded in paraffin. Image Credit: Carl Zeiss Microscopy GmbH
The company Schmidt Verpackungstechnik has been producing on the german market for 20 years.We ma……...
Camurus specializes in the development of pharmaceuticals based on advanced and effective drug de……...
nanoComposix is focused on producing precisely engineered nanoparticles and nanocomposite materia……...
The University of New South Wales (UNSW) is one of Australia's leading research and teaching……...
The Scooptram ST2D is a reliable 3.6 metric tonne tramming capacity underground loader which is s……...
Arup is an independent firm of designers, planners, engineers, consultants and technical speciali……...
The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……
Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……
For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……