Introducing XEMIS

The XEMIS series offers highly accurate gravimetric sorption analysis, operating to 200 bar. Changes in the mass of samples are measured as a function of applied pressure and temperature to determine isobars, isotherms and sorption kinetics.

XEMIS is designed to accommodate a complete range of vapor and gas species, including flammables and corrosives. They feature active pressure regulation from 10-2 mbar, meaning XEMIS can offer a controllable pressure range covering 7 orders of magnitude.

The XEMIS series can provide highly accurate, high resolution and reproducible measurements. They can maintain these standards with even small samples sizes or uptakes; offering performance that is unsurpassed in a high-pressure sorption analyzer.

Key Features & Benefits

Fully compatible with corrosive, flammable and toxic gases and vapors

Advanced programmability and full automation

The widest controllable pressure range of any gravimetric sorption analyzer, offering active pressure regulation of 7 orders of magnitude

Able to measure at temperature from 77 K to 500 °C

Exosensing Technology, ideal for operation with aggressive species

Isobar, isotherm and high pressure TGA measurements in one single, automated analysis tool

Optimized performance for sample sizes from 1 mg to 5 g

Symmetric geometry, with exceptionally low total system buoyancy suitable for accurate measurements even at high pressures

Fast, accurate analysis of kinetics and equilibria via the IGA method

The IGA Method

The unique IGA method from Hiden Isochema can be applied independently to every step in a gravimetric sorption measurement. Pressure and temperature are actively regulated at each step of the process, with the resultant changes in sample weight continuously recorded.

With the IGA method, kinetic weight data is analyzed in real time. The trend toward equilibrium is then predicted and displayed. Criteria for equilibration are applied to objectively determine the ideal measurement period before the system moves on to the following temperature or pressure value. Each point of the equilibrium is plotted on an isobar or isotherm, with the full daw data also recorded.

The IGA method allows consistent analysis and optimum measurement accuracy – two key factors in ensuring faster overall process times.

Applications

Typical applications include:

Carbon capture and storage

Hydrogen and natural gas storage

Gas solubility in ionic liquids

Nanoporous material characterization

Gas sorption on geological materials

[XEMIS Series – Gravimetric Sorption For Hydrogen Storage and Carbon Capture]相关推荐
Promimic AB

Promimic AB

Promimic is a biomaterial company founded in 2004 as a spin-off from research performed at Chalme……...

Wanxu Electric Co., Ltd.

Wanxu Electric Co., Ltd.

Established in 1987, Wanshih Electronic Co., Ltd., is a 50/50 joint venture company by Wonderful ……...

今日仪器
  1. Institute of Microelectronics

    Institute of Microelectronics

    Established in 1991, the Institute of Microelectronics (IME) is a research institute under Singapore’s Agency for Science, Technology and Research (A*STAR). In IME, we focus on delivering hig……

    代理品牌 2025-07-30

  2. Micropol Limited

    Micropol Limited

    Micropol is based in Stalybridge, Cheshire and has over 30 years experience in polymers. Out technical expertise is world class and out customers world wide. Our extensive in-house facilities allow……

    代理品牌 2025-07-30

  3. RAS Process Equipment

    RAS Process Equipment

    RAS Process Equipment , was established in 1977 and is committed to the design, engineering and manufacturing of quality process equipment for our customers. Equipment can be manufactured to the AS……

    代理品牌 2025-07-30

返回顶部小火箭