Vapor pressure is a fundamental physical property of a material. It is expressed as a function of temperature and there is a relationship between vapor pressure and the Gibbs free energy of the original solid/liquid material.
Handling materials such as pharmaceutical samples and pesticides requires knowledge of vapor pressure so that the atmospheric build-up of toxic compounds is avoided. It is necessary to register the vapor pressure of materials to the EC (European Community) or EPA (US Environmental Protection Agency).
Vapor pressure analyzers (VPAs) use the Knudsen effusion method for vapor pressure measurement of oils, liquids and solids. The Knudsen effusion method is a method approved by the Organization for Economic Cooperation and Development and is mentioned in its Vapor Pressure OECD/OCDE Guideline 104.
Knudsen Effusion Method
As a dynamic gravimetric technique, the Knudsen effusion method is based on the rate at which vapor molecules escape into vacuum through an orifice of known dimensions present in a Knudsen cell (Figure 1) at a known temperature.
Figure 1. The Knudsen cell
The VPA system is equipped with the UltraBalance from Surface Measurement Systems Ltd to measure the rate of mass loss via the orifice. It is possible to analyze a sample mass range of 1-100mg at a temperature range of 20-40°C.
The typical analysis begins with placing the sample in a titanium Knudsen cell consisting of an orifice and heating it to experimental temperatures. The rate of mass loss and the vapor pressure of condensed phase (P) are related by the Knudsen equation as follows:
Where,
dm/dt = The rate of mass loss within the Knudsen cell with respect to time
M = The sample molar mass (mol/g)
R = The universal gas constant
T = Temperature and A = Area
dm/dt represents the slope value obtained from the experimental mass data fitted by the least square regression over a specific period of time (Figure 2). The vapor pressure can then be calculated by applying the dm/dt value in equation above.
Figure 2. Mass versus time data from Knudsen cell
The equation below expresses the Clausius–Clapeyron equation, where the values of the constants A and B can be determined using a set of measured vapor pressures at various temperatures. This, in turn, allows calculating the enthalpy of vaporization (ÄH) or heat of sublimation.
VPA Analysis Software - DVS Vacuum Analysis
The following are the key features of the VPA analysis software:
Knudsen vapor pressure analysis
Windows®-based graphical interface
Flexible data-range selection
One-click data analysis and report generation
Easy importing of results from various methods for simultaneous analysis
VPA Control Software - DVS Vacuum Control
The following are the key features of the VPA control software:
Quick-set methods
Incubator and pre-heater temperature control
Real-time display of experiment progress
Turbo pump control
Easy saving and restoring of methods
Balance tare and calibration wizards
Data saved in a tab-separated values (TSV) file
Windows®-based interface
Schematic and Key Components
The schematic of a VPA system is shown in Figure 3:
Figure 3. The schematic of a VPA system
Controlled and stable temperature environment with a temperature range of 20-70°C and stability of ±0.2°C can be obtained for experiments using the temperature- controlled incubators. The sample can be heated up 400°C with the help of the high-temperature local sample pre- heater.
The vacuum system involves a rotary pump capable of producing minimum vacuum pressure of 1 x10-3Torr. Lower vacuum pressure down to 1 x10-7Torr can be achieved when the rotary pump used in conjunction with the turbomolecular pump.
The vacuum transducer operates in the range between 900 and 1x10-8Torr, thus allowing measurement of ultimate vacuum pressure. Vacuum manifold is made principally of 316 stainless steel for chemical inertness, VCR sealed (Cu) fittings and KF flanges.
The ultra microbalance has a resolution of 0.1µg and peak-to-peak noise of = 0.7µg, enabling real-time sample mass measurement of up to 1.0g with a mass change of up to ±150mg at a high vacuum and given temperature.
Experimental Data
Figures 4 to 7 present the experimental data:
Figure 4. Vapor pressure of Bifenthrin is too low to be measured at 25°C, but can be extrapolated from the DVS Vacuum data recorded at 65°C.
Figure 5. Plot of vapor pressure data for Bifenthrin
Figure 6. Plot of vapor pressure data for benzoic acid
Figure 7. Vapor pressure of Caffeine vs temperature stability study. The lower vapor pressure of Form II shows it to be the more stable polymorph.
CPS is the World Leader in providing AlSiC thermal management materials and electronic packaging ……...
The versatile ZEISS Smartproof 5 widefield confocal microscope is an integrated system for surfac……...
PARC Corporation is Located in Romeoville, Illinois USA, a Western Suburb of Chicago centrally l……...
Founded in 1983, MA LABS is one of the leading computer component distributors in the United Stat……...
ASCONA is the market and technology leader for complete solutions in optical profile measuring te……...
Since 1990, CS Unitec has developed a line of high-quality, professional power tools and non-spar……...
The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……
Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……
For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……