Southern Copper Corporation
Southern Copper Corp. mining operations are located in Peru and Mexico. We own and operate four o……...

If users wish to execute non-destructive mapping of grain morphology in 3D to describe materials like metals, ceramicsor alloys, they can find out the first commercially available laboratory-based diffraction contrast tomography (DCT) method for entire three-dimensional imaging of grains in the sample.
Two strong solutions — LabDCT Pro and CrystalCT — enable users to directly envision the 3D orientation of the crystallographic grain. Programmed with the advanced GrainMapper3D software, it sets the stage to examine a range of polycrystalline materials.
Applications
ZEISS Xradia Versa LabDCT Pro and Xradia CrystalCT develop materials modeling, characterizationand breakthrough via ground-breaking diffraction scanning modes.
Allows scanning bigger sample volumes
Offers unparalleled sample representivity
Streamlines sample preparation and handling of uneven or realistic sample shapes
Fulfills sample specificity
Increases speed
Having gained inspiration from nature’s golden angle, advanced scanning modes provide a helical phyllotaxis schema to regulate an extensive range of sample sizes and shapes, and overcome a few of the earlier difficulties of traditional DCT:
Helical phyllotaxis when the sample is narrow and tall
Helical phyllotaxis with high aspect ratio tomography (HART) for flat samples
Helical phyllotaxis raster when the sample is huge and broad

Image Credit: Carl Zeiss Microscopy GmbH
The Technology Behind LabDCT Pro and CrystalCT
DCT projection images generate diverse diffraction patterns on the detector depending on their concentrating geometries. In Laue focusing mode, grains generate diffraction spots that are sharp lines on the scintillator-coupled objective-based detector.
Projection geometry utilizes the flat panel detector placed in the defocused or magnifying spot to gather diffraction spots that look like protruding shape profiles of the equivalent diffracting grains.
The LabDCT Pro module on the ZEISS Xradia 620 Versa allows grain mapping on both the steadfast 4X DCT objective and on the optional flat panel detector offering the flexibility to select between high resolution or high throughput large area grain mapping while ZEISS Xradia CrystalCT uses its dedicated flat panel detector in projection mode.

LabDCT Pro: Laue focusing geometry with the 4X DCT objective. Image Credit: Carl Zeiss Microscopy GmbH

LabDCT Pro or CrystalCT: Projection or Laue focusing geometry onto a flat panel detector. Image Credit: Carl Zeiss Microscopy GmbH
Southern Copper Corp. mining operations are located in Peru and Mexico. We own and operate four o……...
SiO2 Nanotech, LLC was incubated in March 2010, from SiO2 Associates, an informal partnership. Si……...
Poly-Med, Inc. is the leader in the design and production of bioresorbable products. With the abi……...
H & H Polishing, Inc. Specializes in Metal Grinding, Metal Polishing & Metal Buffing Serv……...
We are Materials Services The industrial landscape is undergoing a paradigm shift. Competition an……...
Since 1962, Dolan-Jenner has grown as one of the leading manufacturers of fiber optic components ……...
Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……
SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……
AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……