United American Metals Corp.
Umicore is a materials technology group. Its activities are centered on four business areas: Adva……...
If users wish to execute non-destructive mapping of grain morphology in 3D to describe materials like metals, ceramicsor alloys, they can find out the first commercially available laboratory-based diffraction contrast tomography (DCT) method for entire three-dimensional imaging of grains in the sample.
Two strong solutions — LabDCT Pro and CrystalCT — enable users to directly envision the 3D orientation of the crystallographic grain. Programmed with the advanced GrainMapper3D software, it sets the stage to examine a range of polycrystalline materials.
Applications
ZEISS Xradia Versa LabDCT Pro and Xradia CrystalCT develop materials modeling, characterizationand breakthrough via ground-breaking diffraction scanning modes.
Allows scanning bigger sample volumes
Offers unparalleled sample representivity
Streamlines sample preparation and handling of uneven or realistic sample shapes
Fulfills sample specificity
Increases speed
Having gained inspiration from nature’s golden angle, advanced scanning modes provide a helical phyllotaxis schema to regulate an extensive range of sample sizes and shapes, and overcome a few of the earlier difficulties of traditional DCT:
Helical phyllotaxis when the sample is narrow and tall
Helical phyllotaxis with high aspect ratio tomography (HART) for flat samples
Helical phyllotaxis raster when the sample is huge and broad
Image Credit: Carl Zeiss Microscopy GmbH
The Technology Behind LabDCT Pro and CrystalCT
DCT projection images generate diverse diffraction patterns on the detector depending on their concentrating geometries. In Laue focusing mode, grains generate diffraction spots that are sharp lines on the scintillator-coupled objective-based detector.
Projection geometry utilizes the flat panel detector placed in the defocused or magnifying spot to gather diffraction spots that look like protruding shape profiles of the equivalent diffracting grains.
The LabDCT Pro module on the ZEISS Xradia 620 Versa allows grain mapping on both the steadfast 4X DCT objective and on the optional flat panel detector offering the flexibility to select between high resolution or high throughput large area grain mapping while ZEISS Xradia CrystalCT uses its dedicated flat panel detector in projection mode.
LabDCT Pro: Laue focusing geometry with the 4X DCT objective. Image Credit: Carl Zeiss Microscopy GmbH
LabDCT Pro or CrystalCT: Projection or Laue focusing geometry onto a flat panel detector. Image Credit: Carl Zeiss Microscopy GmbH
Umicore is a materials technology group. Its activities are centered on four business areas: Adva……...
The new LAMBDA®365+ double-beam UV/Vis spectrometer provides the performance researchers and ……...
Chemence is a global specialty chemical company with diversified expertise in multiple market seg……...
InduMar Products, Inc. has provided a unique solution since 1986 with our STOP IT® PIPE REPAI……...
Motionlink Ltd offers a wide range of flexible and proven motion and position control components ……...
The YES-G1000LMC™ plasma cleaning system is designed for uniform cleaning of fully loaded l……...
Established in 1991, the Institute of Microelectronics (IME) is a research institute under Singapore’s Agency for Science, Technology and Research (A*STAR). In IME, we focus on delivering hig……
Micropol is based in Stalybridge, Cheshire and has over 30 years experience in polymers. Out technical expertise is world class and out customers world wide. Our extensive in-house facilities allow……
RAS Process Equipment , was established in 1977 and is committed to the design, engineering and manufacturing of quality process equipment for our customers. Equipment can be manufactured to the AS……