Anton Paar’s PSA series features laser diffraction technology that is very helpful for users to determine the particle size and particle size distribution of both dry powders and liquid dispersions from the nanometer up to the millimeter range.

Insights into the material’s particle size and size distribution are necessary for quality control and product development as both these parameters exhibit an effect on the processability as well as the properties of the ultimate product. The instruments of this range boast an experience of over five decades. The world’s first laser diffraction particle size analyzer, the first-ever PSA, was invented in 1967.

PSA 1190

Multi-laser system is available

Measurement range dry: 0.1 to 2500 µm

Measurement range liquid: 0.04 to 2500 µm

PSA 1090

Dual laser system available

Measurement range dry varies from 0.1 to 500 µm

Measurement range liquid varies from 0.04 to 500 µm

PSA 990

Comes with a single laser system

Measurement range dry: 0.3 to 500 µm

Measurement range liquid: 0.2 to 500 µm

Key Features

Compact Two-in-One Design to Measure Both Wet and Dry Samples

The PSA range of instruments comes under the only particle size analyzers that can be equipped with completely combined liquid and dry dispersion modules in a single instrument. Sample dispersion and measurement are performed within the instrument.

This special design avoids the need for the operator to tackle various accessories, perform manual adjustmentsor exchange the hardware. The software allows shifting between liquid and dry dispersion mode with just the click of a mouse, thus saving time and avoiding operation faults.

The PSA Series of Laser Diffraction Particle Size Analyzers

Image Credit: Anton Paar GmbH

Multi-Laser Technology for a Broad Measurement Range

The multi-laser technology offers a wide range of quantifiable particle sizes. The single-laser PSA 990 spans a measurement range from 0.2 to 500 μm. For an even wider range, PSA 1090 and PSA 1190 exhibit a special optical design for diffraction analysis, which involves multiple lasers.

While PSA 1090 has been developed with two lasers to resolve particles as small as 40 nm, PSA 1190 includes a third laser to cover the complete measurement range of up to 2.5 mm. The use of solid-state lasers guarantees that instruments of the PSA series are all set to quantify as soon as they are switched on. This is because almost no warm-up time is needed.

The PSA Series of Laser Diffraction Particle Size Analyzers

Image Credit: Anton Paar GmbH

Accurate Size Distribution of Dry Powders

In general, it is hard to quantify the size distribution of dry powders since the particles tend to agglomerate, which falsifies the outcomes. Dry Jet Dispersion (DJD) technology is Anton Paar’s patented method (FR2933314) for effectively dispersing and accurately examining powder particles.

The novel design includes an air pressure regulator that rapidly and easily adjusts the air flow according to the sample properties. The shear forces made by the air flow isolate agglomerated particles, which ensures that primary particles are detected.

The PSA Series of Laser Diffraction Particle Size Analyzers

Image Credit: Anton Paar GmbH

Accuracy, Repeatabilityand Stability for a Lifetime

Anton Paar’s particle size analyzers are completely compliant with ISO 13320 standard to satisfy the needs of precise, traceableand repeatable outcomes. The special design of the lasers and the optical bench establish the market standard for measurement reproducibility that is over 1 % variation.

Furthermore, the optical bench design consists of all optical components permanently mounted on a cast-iron base plate. This guarantees realignment-free operation, thereby making PSA the perfect instrument not just for R&D environments but also for tough settings. Therefore, stability, reproducibilityand precision are ensured for the entire lifetime of the instruments.

The PSA Series of Laser Diffraction Particle Size Analyzers

Image Credit: Anton Paar GmbH

Technical Specifications

Source: Anton Paar GmbH

PSA 990 PSA 1090 PSA 1190
Measurement principle Laser diffraction
Measuring range (dry) 0.3 μm to 500 μm 0.1 μm to 500 μm 0.1 μm to 2500 μm
Measuring range (wet) 0.2 μm to 500 μm 0.04 μm to 500 μm 0.04 μm to 2500 μm
Dry dispersion Venturi Venturi Venturi/Freefall
Liquid dispersion 2 peristaltic pumps/ultrasonic transducer/stirrer
Repeatability <1%
Accuracy <3%
Measuring time <1 min
Number of lasers 1 2 3
Laser safety classification FDA Title 21 CFR - Part 1040 & EN 60825-1:2014
Laser class, closed cover Class 1 of EN 60825-1:2014
Laser class, open cover Class 3R of EN 60825-1:2014
Digital data security FDA Title 21 CFR - Part 11
Electromagnetic compatibility EN 61326-1:2013
Low voltage EN 61010-1:2010 & EN 61010-2-081:2015
Dimensions (L x D x H) 890 mm x 530 mm x 430 mm; 35 in x 21 in x 17 in
Weight ~55 kg

Particle Size Analyzer: PSA | Liquid & dry measurements

Video Credit: Anton Paar GmbH

[The PSA Series of Laser Diffraction Particle Size Analyzers]相关推荐
Biochrom Ltd.

Biochrom Ltd.

Biochrom has a long history of making quality scientific instruments for a wide range of applicat……...

MILLENNIUM SILVER CORP.

MILLENNIUM SILVER CORP.

Millennium Silver Corp. is focused on the acquisition, exploration and development of precious me……...

Vacuum Processes, Inc.

Vacuum Processes, Inc.

VPI is a complete turnkey design, manufacturing, service, engineering, research, and installation……...

今日仪器
  1. Borealis AG

    Borealis AG

    For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……

    代理品牌 2025-04-28

  2. EMCCD Cameras - iXon Series

    EMCCD Cameras - iXon Series

    The iXon EMCCD cameras from Andor are scientific digital cameras particularly designed to drive the absolute best from EMCCD technology across all performance parameters and specifications. The ult……

    仪器产品 2025-04-28

  3. Nanalysis 100e Benchtop NMR

    Nanalysis 100e Benchtop NMR

    Nanalysis’ 100e benchtop NMR works on the basis of world’s most robust compact magnet platform at 100 MHz. This single-channel spectrometer has been designed for high-performance regula……

    代理品牌 2025-04-28

返回顶部小火箭