Lochinvar Corporation
From modest beginnings, Lochinvar has evolved into a major manufacturer and innovator of new prod……...
The Optistat™Dry TLEX model from Oxford Instruments provides a temperature controlled sample-in-exchange gas environment, making it the most versatile cryogen free or Cryofree® top loading cryostat, optimized for various spectroscopy experiments.
The OptistatDry Cryofree series of cryostats for spectroscopy helps to cool samples to helium temperatures without using liquid cryogens. It consists of a range of compact cryostats with optical access that is cooled by a closed cycle refrigerator.
These cryostats offer major benefits, such as running costs and ease-of-use. The systems allow electrical and optical measurements to be performed on the user’s samples. These form a part of Oxford Instruments superior performance Optistat series.
Exchange Gas Environment
The OptistatDry – TLEX model is perfect for samples that possess low thermal conductivity, including powder or liquid form. Samples for life science, biological, or chemistry experiments generally cannot be used in a vacuum environment.
In addition to its sample-in-exchange-gas environment, the OptistatDry provides all of the cooling that is required for the samples that are not suited for a vacuum environment.
Top Loading Capability
Regardless of the sample type, the OptistatDry - TLEX model can be used to increase sample throughput and reduce the time between experiments. Removing the sample rod while the cryostat is kept cold allows the user to switch from one sample to the next in a few minutes.
Related Content
Using a Top-Loading OpstistatDry Cryostat for Low Temperature Photolysis Studies of Vitamin B12
The user can leave the cryostat in situ on the optical bench while changing the sample, eliminating the need for time-consuming re-alignment of the user’s optical arrangement.
Key Features
The main features of the OptistatDry - TLEX model are as follows:
Fast sample change within five minutes through top loading probe
Broad sample temperature ranging between <4 and 300 K
Optimized optical access with f1 and a clear view with a diameter of 15 mm
Wide range of different sample holders - windows and wiring options enable the user to upgrade their system as experimental needs develop
Key Benefits
The main benefits of the OptistatDry TLEX model are as follows:
Ease of Use
Available options include water or air-cooled compressors; single phase electrical power allows the system to be easily installed in all standard laboratory environments
Liquid cryogens not required
Versatile
Can be interfaced with all kinds of optical benches; the feet match both metric (25 mm spacing) and Imperial (1 inch spacing)
Perfect for a broad range of spectroscopy applications - including FTIR, Raman, Photoluminescence, etc.
Optical excellence
Large clear optical access and f1 comes as standard
A broad range of various window materials are offered in order to match varied wavelengths; anti-reflection coatings, and wedged windows are also available
Upgradeable
A broad range of distinct windows, sample holders and wiring options allows to upgrade the system as users experimental needs increase
Designed with a modular philosophy that enables the cryostat to evolve with the user’s experiment, enabling the user to begin with a basic system. Later as experimental needs increase, the user can upgrade to additional functionality, such as, add different windows, sample holders, and extra wiring
Applications
The main areas of applications of the OptistatDry - TLEX model are as follows:
Photoluminescence - At low temperatures, spectral attributes are sharper and stronger, increasing the quantity of data available
UV/Visible spectroscopy - Experiments conducted at low temperatures expose the interaction between the electronic energy levels and vibrational modes in solids
Infrared spectroscopy - Measuring changes in interatomic vibrational modes as well as other phenomena, such as the energy gap in a superconductor below its transition temperature can be performed using low temperature IR spectroscopy
Raman spectroscopy - Lower temperatures result in narrower lines linked with the observed Raman excitations
Electrical properties - Electrical and optical measurements including I-V curves
From modest beginnings, Lochinvar has evolved into a major manufacturer and innovator of new prod……...
K2 Energy Limited is an Australian publicly listed company listed on the Australian Stock Exchang……...
Luxium Solutions serves a diverse set of high reliability applications across medical imaging, se……...
Ceramaret designs and produces components out of the hardest of materials such as Advanced Cerami……...
Beyond Sepro’s long-established history of supplying mineral processing equipment, the comp……...
UbiQD is an advanced materials company powering product innovations in agriculture, clean energy,……...
Teikuro Since 1987 providing Hard Chrome Surface Treatment to the North American automotive stamping industry. In addition to automotive stamping dies, our Hard Chrome product is now being utilized……
As the birthplace of public higher education in America, the University of Georgia is inspiring the next generation of entrepreneurs, researchers, and informed citizens who will change the world. F……
Scope Technology Inc. has been in business since 1994 manufacturing affordable Industrial Fiberscopes, Videoscopes and Remote Visual Inspection Devices. We manufacture stock items and we also produ……