AutoX750 Automatic Contacting Extensometer from Instron
Instron offers an advanced, high-resolution automatic contacting extensometer that is suitable fo……...
The MAX300-CAT is a quantitative gas analyzer with high-sensitivity, used for environmental research, reaction monitoring, and catalysis.
This quadrupole mass spectrometer is powerful and fast, and performs high precision quantitative analysis of every component present in a gas or vapor mixture. This spectrometer can also be equipped for the fully-automated sampling of multiple gas channels.
The MAX300-CAT has the ability to track concentration changes from ppb levels to 100% and provide continuous data updates within seconds. The spectrometer is a flexible, compact platform optimized for gas reaction studies in environmental analysis, process development, bioreactor control, and catalysis.
MAX300-CAT Laboratory Gas Analyzer- The MAX300-CAT is fast, compact, and easy to use. It can measure any gas or vapor sample concentration from ppb levels to 100%. Image Credit: Extrel
Laboratory Gas Analyzer Features
Complete quantitative sample composition
Measures any gas or vapor sample
Multiport sample selector for 61+ samples
High sensitivity: detection limit 500 ppb
Data acquisition: up to 1000 measurements/second
1-100, or 1-300 amu mass range
Fast response: measures changes to sample concentration in <300 ms
Real-time analysis of the input and effluent streams reveal what is happening in the reaction
MAX300-CAT Quadrupole Advantage
An ionizer is used by the mass spectrometer to break sample molecules into charged fragment ions that are separated based on their mass-to-charge ratio as they travel through the electric fields produced by the quadrupole mass filter.
The ions register a current at the detector creating a set of peaks known as a mass spectrum. Each compound has a unique spectrum.
Accurate Data, Endless Utility
Users can simply select the gases to measure, or the mass range to scan, in the software and the MAX300-CAT is configured to monitor a new process or reaction.
|
CatalysisGas and Vapor AnalysisCombustion StudiesProcess DevelopmentTPD/ TPO/TPRVapor DepositionReaction Monitoring and Kinetics |
|
Bioreactor MonitoringGas Phase SynthesisOrganic ChemistryEvolved Gas Analysis |
|
Fuel Cell StudiesEnvironmental ResearchAlternative FuelsAir MonitoringGasification |
|
Gas MixingTrace ContaminationPure Gas AnalysisScrubber EfficiencyFood and Beverage GasSemiconductor ManufacturingPharmaceutical Solvents |
System Specifications:
Detectable compounds: Any vapor or gas sample
Detection range:
Dual detector option: 100% - 0.5 ppm
Faraday detector: 100% - 20 ppm
Analysis rate: Up to 1000 measurements per second
Gas consumption: 10 µL/min
Ionization energy control for reduced fragmentation
Heated inlet option available
Software:
VacuumPlus control software
Questor5 quantitative analysis package
Computer interface: USB or RS-232C
Filaments: Two, one active and one spare
Over-pressure protection provided by built-in Pirani and BA gauges
Mass range options: 1-200, 1-300 amu
6 mm quadrupole mass filter
Power supply: 110/230 VAC, 50/60 Hz
Weight: 55 lbs. (25 kg)
Dimensions (L x W x H): 465 x 465 x 571 mm
Image Credit: Extrel
Exceptional Worldwide Service and Support
Extrel has provided the highest quality support services have been provided for over 50 years for the thousands of instruments installed worldwide. Customers are provided with industry-leading support from certified and factory trained personnel at all stages of the analytical process.
Questor5 Quantitation Software Features
Image Credit: Extrel
Continuous, real-time, total composition measurements of any vapor or gas sample
Component | [C] (%) | STD (% absolute) |
---|---|---|
H2 | 0.6 | 0.03 |
N2 | 78 | 0.06 |
O2 | 20.9 | 0.06 |
Ar | 0.93 | 0.0075 |
CO2 | 0.05 | 0.003 |
Completely automated, high stability, high precision quantitative analysis of multiple sample streams
Number of analysis routines: Unlimited
Number of components: Unlimited
Automated or manual calibration
Data recorded as % or ppm
Automatic removal of spectral overlap
Sample selector configurations:- 16, 31, 46, 61+
Security levels: viewer, user, administrator
Security: 21 CFR Part 11
Analysis can be activated by external devices
External communications
Digital I/O, Modbus serial, Ethernet, OPC, analog I/O
Comprehensive spectral library included
NIST MS database and spectrum matching software optional
Number of user configurable data tags and alarms: Unlimited
Instron offers an advanced, high-resolution automatic contacting extensometer that is suitable fo……...
Amazing insights and innovative products using Tekscan pressure mapping, force measurement, and t……...
RJH, like many machine tool companies, owes its origin to the UK textile industry for which Heckm……...
For customers that need greater length for their mechanical testing, Testometric offer an alterna……...
Vynacol Limited is a joint venture company formed by Colour Tone Masterbatch and the MetPro Group……...
Alcomet Limited was founded in 1998 by its current managing director, Gary James and in the compa……...
Teikuro Since 1987 providing Hard Chrome Surface Treatment to the North American automotive stamping industry. In addition to automotive stamping dies, our Hard Chrome product is now being utilized……
As the birthplace of public higher education in America, the University of Georgia is inspiring the next generation of entrepreneurs, researchers, and informed citizens who will change the world. F……
Scope Technology Inc. has been in business since 1994 manufacturing affordable Industrial Fiberscopes, Videoscopes and Remote Visual Inspection Devices. We manufacture stock items and we also produ……