Source: Metrohm USA Inc.
. | . |
---|---|
Operating modes | Bipotentiostat; Potentiostat; Galvanostat |
PC interface | USB |
Power | 12 V DC |
Potential range in volt | ±4 V |
Maximum current in Ampère | ±40 mA |
Number of current ranges | 8 |
Number of current ranges remarks | ±1 nA to ±10 mA |
Number of potential ranges (galvanostat) | 2 |
Number of potential ranges remarks (galvanostat) | ±100 mV to ±1 V |
Multichannel instrument | NO |
Maximum number of channels | 1 |
Maximum number of WE sharing AUX and REF | 2 |
Potential accuracy | ±0.2% |
Current accuracy | ≤0.5% of current range at 100 nA to 10 mA |
Potential resolution | 1 mV |
Current resolution | 0.1% of current output range |
Measured potential resolution | 0.012% of potential range |
Measured current resolution | 0.025% of current range |
Spectrometer (SPM) Detector | Linear silicon CCD array |
SPM Pixels | 2048 |
SPM Pixel size | 14 µm x 200 µm |
SPM Pixel well depth | 62,500 electrons |
SPM Wavelength range | 200-900 nm |
SPM Optical resolution | 0.3+10.0 nm FWHM |
SPM Signal-to-noise ratio | 250:1 (at full signal) |
SPM A/D resolution | 16 bit |
SPM Dark noise | 50 RMS counts |
SPM Dynamic range | 8.5 x 10 rised to 7 (system) ; 1300:1 for a single acquisition |
SPM Integration time | 1 ms to 65 seconds |
SPM Stray light | ≤ 0.05% at 600 nm ; < 0.10% at 435 nm |
Light Source (LS) wavelength range | 215-400 nm (deuterium) ; 360-2500 nm (tungsten halogen) |
LS Stability | 1.0% peak-to-peak (over 4 hours) after 30-minute warm-up |
LS Time to stable output | 10 minutes (deuterium) ; 1 minute (tungsten halogen) |
LS Ignition delay | <2.0 seconds (delay for cold start-up may be longer) |
LS Bulb life | >1,000 hours @ 240 nm (time); <50% @ 240 nm (decrease of intensity) ; Continuous operation (testing conditions) |
LS Fiber optic connector | SMA 905 |
Dimensions | 24 x 11 x 25 |
Weight of the instrument in kg | 1.95 |
The University of Bath is a leading UK research university, dedicated to making a positive impact……...
The VistaScope models from Molecular Vista are supplied with the revolutionary Photo-induced Forc……...
The Thermo Scientific™ SamStat-30 representative slurry sampling station provides composite……...
CUSTODIAM, as close partner of a major diamond tools manufacturer, has built up a true science of……...
Heat Technology Products has established itself as a leader in the industrial heat transfer indus……...
The OptiCool by Quantum Design is an innovative magneto optical cryostat that places your sample ……...
The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……
Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……
For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……