Gyrotron Technology, Inc.
Established in 1998, GTI is an industrial technologies company developing heat-treatment processe……...

SPELEC is a tool for spectroelectrochemical measurements. It comprises a spectrometer (UV-VIS wavelength range: 200-900 nm), a bipotentiostat/galvanostat, and a lightsource in one box.
It also comes with specialized spectroelectrochemical software that enables the synchronization of optical and electrochemical studies.
Tech Specs
Source: Metrohm USA Inc.
| . | . |
|---|---|
| Operating modes | Bipotentiostat; Potentiostat; Galvanostat |
| PC interface | USB |
| Power | 12 V DC |
| Potential range in volt | ±4 V |
| Maximum current in Ampère | ±40 mA |
| Number of current ranges | 8 |
| Number of current ranges remarks | ±1 nA to ±10 mA |
| Number of potential ranges (galvanostat) | 2 |
| Number of potential ranges remarks (galvanostat) | ±100 mV to ±1 V |
| Multichannel instrument | NO |
| Maximum number of channels | 1 |
| Maximum number of WE sharing AUX and REF | 2 |
| Potential accuracy | ±0.2% |
| Current accuracy | ≤0.5% of current range at 100 nA to 10 mA |
| Potential resolution | 1 mV |
| Current resolution | 0.1% of current output range |
| Measured potential resolution | 0.012% of potential range |
| Measured current resolution | 0.025% of current range |
| Spectrometer (SPM) Detector | Linear silicon CCD array |
| SPM Pixels | 2048 |
| SPM Pixel size | 14 µm x 200 µm |
| SPM Pixel well depth | 62,500 electrons |
| SPM Wavelength range | 200-900 nm |
| SPM Optical resolution | 0.3+10.0 nm FWHM |
| SPM Signal-to-noise ratio | 250:1 (at full signal) |
| SPM A/D resolution | 16 bit |
| SPM Dark noise | 50 RMS counts |
| SPM Dynamic range | 8.5 x 10 rised to 7 (system) ; 1300:1 for a single acquisition |
| SPM Integration time | 1 ms to 65 seconds |
| SPM Stray light | ≤ 0.05% at 600 nm ; < 0.10% at 435 nm |
| Light Source (LS) wavelength range | 215-400 nm (deuterium) ; 360-2500 nm (tungsten halogen) |
| LS Stability | 1.0% peak-to-peak (over 4 hours) after 30-minute warm-up |
| LS Time to stable output | 10 minutes (deuterium) ; 1 minute (tungsten halogen) |
| LS Ignition delay | <2.0 seconds (delay for cold start-up may be longer) |
| LS Bulb life | >1,000 hours @ 240 nm (time); <50% @ 240 nm (decrease of intensity) ; Continuous operation (testing conditions) |
| LS Fiber optic connector | SMA 905 |
| Dimensions | 24 x 11 x 25 |
| Weight of the instrument in kg | 1.95 |
Established in 1998, GTI is an industrial technologies company developing heat-treatment processe……...
MS Industrie AG 总部位于慕尼黑,是一家专注于技术集团的上市母公司,旗下拥有两大业务领域:动力传动……...
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ Ansun Protective Metals,Inc .-锌阳极,溅射靶标和定制合金的制造……...
The 5100 Series has a patented SPILLPRUF spill control system, accurate honeycomb construction, 3……...
Phila Optics Inc. was established in 1995 by experienced optical professionals to provide a broad……...
Users can now unleash the acquisition speed of up to 91 parallel electron beams with ZEISS MultiS……...
Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……
SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……
AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……