Rapid and Easy Determination of Fluorescence Lifetime with the Quantaurus-Tau Spectrometer

上海仪舶实验室自动化 25-01-23 16:40:50

Rapid and Easy Determination of Fluorescence Lifetime with the Quantaurus-Tau Spectrometer

Hamamatsu’s Quantaurus-Tau is a compact system developed for measuring fluorescence lifetimes starting from subnanosecond to the millisecond range.

The system can be operated easily; users simply place the sample into the sample chamber and enter a number of conditions on the measurement software to determine the PL spectrum and fluorescence lifetime in a short period of time with excellent accuracy. Analysis results can be acquired in just 60 seconds for a standard measurement.

The fluorescence spectrum, acquired from a fluorescent probe or an organic material, is a key parameter to assess and control the characteristics and functions of materials, such as the fluorescence intensity and peak wavelength. A fluorescence spectrum will often display time-integrated data and when different reactive elements and substances are present in the material, their fluorescence spectrum can only be obtained as an integrated data.

In such situations, the best way would be to view the light emission dynamics using the time axis parameter. This is often referred to as fluorescence lifetime measurement, where the time needed for the substance - which is activated by the pulsed light to return to its ground state - is determined in the sub-nanosecond to millisecond range. Through this measurement more data can be obtained, such as many different fluorescence lifetimes at the same percentage and wavelength in which they exist in the material.

Download the Brochure for More Information

Key Features

Space-saving, compact design

Easy and rapid measurement

Fluorescence spectrum measurements

Time resolution better than 100 ps (by deconvolution)

High sensitivity measurement by photon counting method

Seven excitation wavelength – 280, 340, 365, 405, 470, 590, and 630

Two selection of detector: C11367-31/-34 (standard) and C11367-32/-35 (NIR)

Analysis of different sample forms

Optional cooling function for solution sample (-196°C)

Optional phosphorescence measurement

[Rapid and Easy Determination of Fluorescence Lifetime with the Quantaurus-Tau Spectrometer]相关推荐
ESTA Extraction technology

ESTA Extraction technology

We have been developing efficient extraction systems for over 50 years and putting our efforts in……...

GVD Corporation

GVD Corporation

GVD’s achievement incommercializing vapor deposited polymer coatings has positioned the com……...

Carbis Loadtec Group Ltd

Carbis Loadtec Group Ltd

Carbis Loadtec Group is the exclusive technical supplier for fall prevention systems and high qua……...

今日仪器
  1. ANGEL BIT from Quarry Mining & Construction Equipment Pty Ltd

    ANGEL BIT from Quarry Mining & Construction Equipment Pty Ltd

    The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……

    仪器产品 2025-04-28

  2. Jetcrete Australia

    Jetcrete Australia

    Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……

    代理品牌 2025-04-28

  3. Borealis AG

    Borealis AG

    For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……

    代理品牌 2025-04-28

返回顶部小火箭