Torque Screwdriver Calibration with the TSCC
The Mecmesin TSCC torque screwdriver check calibration system is a fast throughput, semi-automate……...
The outstanding manufacturing capabilities of B&W Tek bring to you the Raman Building Block 785 that allows users to configure a standalone spectrometer system using the unique flexible OEM setup.
The OEM modular system of the building block caters to all unique demands and can be easily customized depending on the applications. This easy-to-use setup is comprised of a 785 nm laser, a spectrometer, a sampling probeand other optional accessories. Users can build a suitable breadboarding system toDiscover It Yourselfdepending on their requirements.
Features
High-quality, precisionparts to suit all prototyping essentials
Fiber-optic probe with external trigger and customized sampling options
Patented CleanLaze® technology for laser stabilization
Building Blocks can be customized to suit users’ demands
Image Credit: B&W Tek
Software
Solutions that are appropriate for Raman applications are offered by B&W Tek’s BWSpec® software and Software Development Kit (SDK) packages.
BWSpec®
BWSpec®, a spectral data acquisition software, is the base of all B&W Tek instruments. The software package comprises tools that can perform measurement and calculations at the ease of a button. Users can retrieve data in multiple formats and optimize acquisition parameters such as laser power and integration time. Manual/auto baseline correction and automatic dark removal are also some of its unique features.
Software Development Kit (SDK)
B&W Tek’s customized interface allows users to control spectroscopic instruments through SDKs. Simple laser and spectrometer regulation of calibration, data acquisitionand module synchronization can be performed. Although it is designed for 32- and 64-bit Windows operating systems, all USB-based spectrometers can make use of this SDK package.
If users are looking for full system control, then an advanced package with chemometric model support and data processing algorithms is available using models from the BWIQ software. Some of the mathematic functions that enable the delivery of a comprehensive solution spectrometer system include peak finding, curve fitting, a prediction engineand smoothing.
The 785 nm Raman Building Block has three breadboard configurations. Efficient engineers have designed each building block with the highest quality components. Every block ensures that users achieve the most precise and efficient approach to attain their objective.
Table - 1. Source: B&W Tek
Entry Block | Professional Block | Research-Grade Block | |
---|---|---|---|
Spectrometer Options | Glacier® TBTC162E-785S | Exemplar® TBTC665N-785S | Exemplar® HTBTC667N-785S |
Excitation Wavelength | 785 nm | 785 nm | 785 nm |
Raman Shift Coverage | 150 to 3200 cm-1 | 150 to 3350 cm-1 | 150 to 3350 cm-1 |
Coverage Range | 788 nm to 1050 nm | 788 nm to 1067 nm | 788 nm to 1067 nm |
Resolution | 4.5 cm-1 @ 912 nm | 4.5 cm-1 @ 912 nm | 4.5 cm-1 @ 912 nm |
Detector Type | 2048-elementResponse-Enhanced linear silicon CCD Array | 2048-elementHigh Quantum EfficiencyBack-Thinned CCD Array | 2048-elementHigh Quantum EfficiencyBack-Thinned CCD Array |
Thermoelectric Cooling | 14 °C | -2 °C | Deep cooled at -25 °C(Δ 50 °C minimum) |
Dimensions | 191 mm × 94 mm × 90 mm(7.5 ” × 3.7 ” × 3.5 ”) | 200 mm × 180 mm × 120 mm(7.8 ” × 7.1 ” × 4.0 ”) | 220 mm × 180 mm × 130 mm( 8.7 ” × 7.1 ” × 5.1 ”) |
Weight | 3.9 lbs. ( ~1.8 kg) | 5.4 lbs. ( ~2.5 kg) | 7.6 lbs. ( ~3.4 kg) |
Note: The start range of Raman shift is dependent on the selected probe.For more spectrometer model customization options, datasheets, and price information please contact us
Laser Options
The 785-nm laser product is designed according to the requirements of customers and sold as a module or a component to fit into other equipment. The customer should ensure that the equipment complies with the US FDA21 CFR 1040 standards before selling in the market.
Table - 2.Source: B&W Tek
Probe Options | Industrial-Grade | Lab-Grade |
---|---|---|
Model Number | BAC101-SS-785 | BAC100B-785 |
Excitation Wavelength | 785 nm | 785 nm |
Laser Blocking | OD6 Default | OD6 Default |
Shaft Material | 316 Stainless Steel | 304 Stainless Steel |
Shaft Length | 203.2 mm (8”) | 76.2 mm (3”) |
Shaft Diameter | 12.7 mm (0.5”) | 9.4 mm (0.37”) |
Working Distance | 0.5 mm, 0.8 mm in Liquid | 5.4 mm |
Maximum Operating Temperature | 200 °C | 80 °C; Non-immersive use |
For more probe or laser customization options, datasheets, and price information please contact us.
The Mecmesin TSCC torque screwdriver check calibration system is a fast throughput, semi-automate……...
Southwest Metal Products is located in Windsor, Ontario convenient to all North American Customer……...
With a low cost of ownership, the JEM-2100 Plus Transmission Electron Microscope from JEOL is a v……...
KASTO is the world’s only complete supplier of metal cutting machinery. At KASTO we offer a……...
Since its founding in 1954, Hardric Laboratories, Inc has been a pioneer in the field of ultra-cl……...
The FP-1 vibration isolation floor platform available from Minus K Technology has been specifical……...
Teikuro Since 1987 providing Hard Chrome Surface Treatment to the North American automotive stamping industry. In addition to automotive stamping dies, our Hard Chrome product is now being utilized……
As the birthplace of public higher education in America, the University of Georgia is inspiring the next generation of entrepreneurs, researchers, and informed citizens who will change the world. F……
Scope Technology Inc. has been in business since 1994 manufacturing affordable Industrial Fiberscopes, Videoscopes and Remote Visual Inspection Devices. We manufacture stock items and we also produ……