BI-870 Dielectric Constant Meter for use with Zeta Potential Measurements
Measure the Dielectric Constant Used in Zeta Potential Measurement with the BI-870. Zeta potentia……...
The QUADRASORB evo Gas Sorption Surface Area and Pore Size Analyzer allows users to run multiple independent samples synchronously at variable start times.
The flexible field upgrade paths provided by Anton Paar enable users to procure equipment depending on their current lab requirements, but with the flexibility of upgrading to micropore capability for low surface area analysis or upgrading analysis stations for optimized throughput at a future date.
Accurate B.E.T surface area measurements can be rapidly obtained with the standard evo™ version. High throughput industrial material characterization labs can analyze multiple samples at drastically improved speeds using the new B.E.T Quick Mode™.
Advanced material characterization can be performed with the micropore equipped version, which can measure extremely low surface area samples and microporous materials with the help of a 1torr low-pressure transducer and turbopump.
QUADRASORB evo Kr/MP for low surface area and micropore measurements features all of the functions of the standard model QUADRASORB evo in addition to low surface area measurement through Krypton adsorption or low-pressure micropore characterization.
It is equipped with low-pressure 1 torr transducersensors and an oil-free turbomolecular vacuum system. It carries out Krypton gas sorption measurements to determine the very low surface area of powdered metals and pharmaceutical actives.
It delivers low-pressure adsorption data (as low as 4 x 10-5 P/Po) crucial for the comprehensive characterization of microporous materials, including activated carbons, zeolites, and molecular sieves.
Key Features
The following are the key features of the new QUADRASORB evo Gas Sorption Surface Area and Pore Size Analyzer:
BET QuickMode for industrial high throughput settings, saving time by up to 50%
Bypasses most initialization, transducer zeroing sequences, and extended evacuation
Can synchronously run multiple samples
Can perform four sample runs within 25min
Dedicated Po transducer and manifold allows continuous sample dosing during measurements:
Po can be continually measured
Po can be updated without stopping the measurement
No slow down in analysis to measure Po
Flexible Po Modes
It is possible to estimate Po from ambient atmospheric pressure
It is possible to enter Po as a fixed value
It is possible to analytically measure Po
New Dose Wizard™ flexibility
Can use a previously measured sample as a dosing template for shortened analysis time
Can be used with or without QuickMode™
New hardware features
Integrated insulated dewar covers included in lift mechanism to increase the life and insulate the dewars content
Stainless steel gas paths including metal-metal seals for optimal vacuum performance
New 1torr low-pressure transducer for Krypton and micropore measurements
Soft closing protective door with pneumatic hinges for operator safety
Smooth belt drive dewar lift for precise control of Anton Paar’s novel cold zone
Key Benefits
The key benefits of the QUADRASORB evo Gas Sorption Surface Area and Pore Size Analyzer are listed below:
RTD sensors at each station ascertain automatic control of coolant at a level, ensuring minimum cold zone and maximum sensitivity
Automated, independent dewar elevators for each analysis station, plus self-adjusting dewar covers
Two measurement techniques are available as options: Patented NOVA® helium-free method or classical helium void volume method.
All stations can utilize 12mm, 9mm or 6mm glassware for maximum flexibility
Long-life dewar flasks for measurements lasting up to 30h with liquid nitrogen
Each of the four analysis ports includes separate and independent dewar (coolant flask) with Po (adsorbate saturated vapor pressure) measurement station, pressure transducer, and coolant level sensor for concurrent measurements yielding optimum flexibility and throughput
It is possible to independently program each analysis with different analyses and measurement conditions
Low maintenance, vacuum volumetric system with temperature monitored dosing manifold
Quadrawin™ software ver 3.0+ is capable of operating up to 3 QUADRASORB units simultaneously, from a single PC
Soft-close transparent blue cover gives protection to dewars and sample stations during analysis and allows users to access analysis stations easily as it opens vertically and automatically closes slowly
Stainless steel dosing and sample manifolds with metal-to-metal (VCR) seals
Communication port for PC control via Windows® based software
Multiple gas dosing methods to improve analysis time and resolution
Standard can modify dose pressure in accordance with sample demands intelligently
Vector Dosing allows user-selectable dose volumes from 0.25 to 10cc per point
Delta (volume) Max™ includes data points in regions of large uptake and therefore no missing of pore filling step
Dose Wizard™ can be used with or without QuickMode™ enabled
This product is a former Quantachrome product. On February 9, 2018, Anton Paar acquired Quantachrome. Under the umbrella of the Anton Paar Group, the company will continue operations in Boynton Beach. Quantachrome is the first manufacturing facility in North America run by Anton Paar and will also function as a US-based unit for research, development, and production within the Anton Paar Group.
Measure the Dielectric Constant Used in Zeta Potential Measurement with the BI-870. Zeta potentia……...
Our expertisealso extends to locked and encrypted drives,RAID Array recovery from larger RAID Arr……...
Donaldson Company, Inc. is a leading worldwide provider of filtration systems and replacement par……...
Established in the year 1992, Endeavour Instrument Pvt Ltd, is an ISO 9001:2008 Certified company……...
Concast has been producing copper alloys in bar and tube form since 1989. In 1995, the company ac……...
Parma Tube Corporation was founded in 1964. We specialize in brazing, flaring, and bending of tub……...
Established in 1991, the Institute of Microelectronics (IME) is a research institute under Singapore’s Agency for Science, Technology and Research (A*STAR). In IME, we focus on delivering hig……
Micropol is based in Stalybridge, Cheshire and has over 30 years experience in polymers. Out technical expertise is world class and out customers world wide. Our extensive in-house facilities allow……
RAS Process Equipment , was established in 1977 and is committed to the design, engineering and manufacturing of quality process equipment for our customers. Equipment can be manufactured to the AS……