DiamoTek 700 Series Microwave Diamond CVD System from Lambda Technologies
The DiamoTek 700 Series Microwave Diamond CVD systems incorporatr tunable resonant cavity technol……...
The Model 876 Piezoelectric Accelerometer from Columbia Research Laboratories has been designed for vibration measurement or tracking applications that need operation at extremely cold temperatures.
The accelerometer is ideal for event and vibration tracking of valves and pumps applied in the cryogenic service.
The shear plate construction offers utmost mechanical isolation from thermal shock transients and strain-induced inputs. The electrically separated and double case construction provides electrostatic shielding as well as decreasing power line frequency noise due to multi-point grounding. The accelerometer equips a 10 to 32 top connector.
Users can consult the factory for tailored versions of this sensor.
Image Credit: Columbia Research Laboratories
Extreme cold temperatureVibration and shock measurements
Electrical isolation
Sealed hermetically
Low base strain sensitivity
Specifications
Source: Columbia Research Laboratories
Transfer / Electrical | 876 |
---|---|
Charge Sensitivity1 @ 75 Deg F Nominal@ -420 Deg F to –295 Deg F | 50 +/-10 pC/g25 pC/g +/-5% |
Capacitance@ 75 Deg F Nominal@ -420 Deg F To –295 Deg F | 4,200 +/-100 pF1,700 pF +/-5% |
Frequency Linearity2 | +/-5% Max2 Hz To 4,000 Hz |
Mounted Resonant Frequency | 20 KHz, Min. |
Transverse Sensitivity | 5% Max |
Amplitude Linearity | +/-1.0% (BFSL) / 2,000 g |
Insulation Resistance | 10,000 M Ohm Min, 50 VDC Test |
Isolation Resistance | 50 M Ohm, Min.Housing to Signal Output Terminals Shorted |
Environmental | 876 |
---|---|
Vibration Limit | 3,000 g Max (Sine) |
Shock Limit | 10,000 g Peak ½ Sine |
Temperature Range | -450 To +300 Deg F (-267 To +149 Deg C) |
Humidity3 | 0 To 100% R.H. |
Base Strain Sensitivity | 0.005 g/μE Equiv, Typical |
Electromagnetic Sensitivity | 0.005 g (Equiv / 100 Gauss) |
Acoustic Sensitivity | 1.0 g Max @ 170 dB Whitenoise 75 To 960 Hz |
Physical | 876 |
---|---|
Configuration | Bolted Shear Plate |
Size | 0.625 In. Hex. x 1.000 In. H (15.9 mm Hex x 25.4 mm H) |
Weight | 1.2 Oz (33 Gm) |
Case Material | 18-8 Stainless Steel |
Electrical Interface | Coaxial 10-32 Thread |
Mounting | 10-32 UNF Tapped Base |
Notes:
1 At +75 Deg F, 10 g Peak, 100 Hz; Lower Frequency Limit is Determined by Associated Electronics2 Referenced to Sensitivity @ 100 Hz.3 Unit is Hermetically Sealed.
Accessories Supplied
Mounting Stud, St Stl measures around 10-32 x 0.5
Standard room temperature calibration data
Comes with a hardwood storage case
Provided with a Certificate of Calibration Traceable to N.I.S.T.
Optional Accessories
Low temperature calibration data
The DiamoTek 700 Series Microwave Diamond CVD systems incorporatr tunable resonant cavity technol……...
Security Engineered Machinery Co Inc, offers more optical media destruction solutions. Optical Me……...
OUR MATERIAL Our patented Cerbide material is a binderlessTungsten Carbide that offers sup……...
Science Stuff began as a consulting business. As a consultant, Sue E. Bachus taught science works……...
Advanced Fuel Research, Inc. (AFR) celebrated its twentieth anniversary in early 2000. The Compan……...
Airex brings the virtues of small company dedication with 50 years of expertise to the marketplac……...
The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……
Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……
For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……