PSI Urethanes, Inc.
PSI Urethanes, Inc. is the Expert Source for Urethane Parts & Products. Urethane products del……...

The Model 876 Piezoelectric Accelerometer from Columbia Research Laboratories has been designed for vibration measurement or tracking applications that need operation at extremely cold temperatures.
The accelerometer is ideal for event and vibration tracking of valves and pumps applied in the cryogenic service.
The shear plate construction offers utmost mechanical isolation from thermal shock transients and strain-induced inputs. The electrically separated and double case construction provides electrostatic shielding as well as decreasing power line frequency noise due to multi-point grounding. The accelerometer equips a 10 to 32 top connector.
Users can consult the factory for tailored versions of this sensor.

Image Credit: Columbia Research Laboratories
Extreme cold temperatureVibration and shock measurements
Electrical isolation
Sealed hermetically
Low base strain sensitivity
Specifications
Source: Columbia Research Laboratories
| Transfer / Electrical | 876 |
|---|---|
| Charge Sensitivity1 @ 75 Deg F Nominal@ -420 Deg F to –295 Deg F | 50 +/-10 pC/g25 pC/g +/-5% |
| Capacitance@ 75 Deg F Nominal@ -420 Deg F To –295 Deg F | 4,200 +/-100 pF1,700 pF +/-5% |
| Frequency Linearity2 | +/-5% Max2 Hz To 4,000 Hz |
| Mounted Resonant Frequency | 20 KHz, Min. |
| Transverse Sensitivity | 5% Max |
| Amplitude Linearity | +/-1.0% (BFSL) / 2,000 g |
| Insulation Resistance | 10,000 M Ohm Min, 50 VDC Test |
| Isolation Resistance | 50 M Ohm, Min.Housing to Signal Output Terminals Shorted |
| Environmental | 876 |
|---|---|
| Vibration Limit | 3,000 g Max (Sine) |
| Shock Limit | 10,000 g Peak ½ Sine |
| Temperature Range | -450 To +300 Deg F (-267 To +149 Deg C) |
| Humidity3 | 0 To 100% R.H. |
| Base Strain Sensitivity | 0.005 g/μE Equiv, Typical |
| Electromagnetic Sensitivity | 0.005 g (Equiv / 100 Gauss) |
| Acoustic Sensitivity | 1.0 g Max @ 170 dB Whitenoise 75 To 960 Hz |
| Physical | 876 |
|---|---|
| Configuration | Bolted Shear Plate |
| Size | 0.625 In. Hex. x 1.000 In. H (15.9 mm Hex x 25.4 mm H) |
| Weight | 1.2 Oz (33 Gm) |
| Case Material | 18-8 Stainless Steel |
| Electrical Interface | Coaxial 10-32 Thread |
| Mounting | 10-32 UNF Tapped Base |
Notes:
1 At +75 Deg F, 10 g Peak, 100 Hz; Lower Frequency Limit is Determined by Associated Electronics2 Referenced to Sensitivity @ 100 Hz.3 Unit is Hermetically Sealed.
Accessories Supplied
Mounting Stud, St Stl measures around 10-32 x 0.5
Standard room temperature calibration data
Comes with a hardwood storage case
Provided with a Certificate of Calibration Traceable to N.I.S.T.
Optional Accessories
Low temperature calibration data
PSI Urethanes, Inc. is the Expert Source for Urethane Parts & Products. Urethane products del……...
Pipe cutting machinery and shut-off valves from Vernon Tool provide solutions to difficult pipe f……...
Heat Technology Products has established itself as a leader in the industrial heat transfer indus……...
The Model EMPX-HF is a versatile cryogenic electromagnet-based micro-manipulated probe station us……...
Bridesburg Foundry Co.started in1914, served a broad base of customers for commercial, industrial……...
Connacher is a growing integrated crude oil and natural gas company with a focus on producing bit……...
Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……
SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……
AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……