Optical Particle Measurement System - CAMSIZER® X2

上海仪舶实验室自动化 25-02-07 11:03:06

Optical Particle Measurement System - CAMSIZER® X2

The new CAMSIZER X2 is ideal for substantially improving the quality control of fine powders: More precise and rapid analysis of particle shape and particle size helps to enhance the product quality, save labor costs, energy and raw materials, and reduce rejects.

The design of the CAMSIZER X2 is based on the renowned optical particle measurement system Camsizer but is optimized for finer samples (from 0.8 µm to 8 mm). An extended application range is allowed because of the enhanced optical resolution and also the new options for material feeding. Fine particles are likely to agglomerate which makes it hard to record the properties of a single particle. It is thus important to have different possibilities of feeding the sample to the analysis area in order to find for each material the optimum between the undesired destruction of the individual particle and the desired dispersion of the agglomerates.

The CAMSIZER X2 provides the flexible X-Change system: from the X-Fall module (free fall mode), which is considered to be the most gentle method for the material, to the X-Jet module with variable nozzle geometry and adjustable pressure and, additionally, the X-Flow module in which particles are dispersed in liquids, optionally by an ultrasonic probe.

Microtrac

Microtrac

Application Examples

abrasives (medium-size and small grit), cement, chemicals, construction materials, activated carbon, detergents and enzymes, foodstuffs (pulverized and granulated), glass beads, metal and ore powders, pharmaceutical powders / granules / fine pellets, plastic powders, plastic fibers, salts, sugar, wood fibers, sand

Product Advantages

Reliable detection of smallest amounts of "oversize" and "undersize"

Extremely short measurement time of 1 - 3 minutes

Modular system X-Change for wet and dry dispersion

Measurement results are 100% compatible to sieve analysis if needed

Intuitive software

Digital image processing with patented two-camera-system (acc. to ISO 13322-2)

Calibration in seconds

Simple handling prevents operating errors

Password protected instrument settings

Automatic measuring procedure

Robust design, insensitive to vibrations and dust

Self-cleaning, maintenance-free, wear-free

Several language versions (English, German and other languages)

Detailed particle size analysis - results are saved in more than 1,000 size classes

Simultaneous analysis of particle size, number, shape, transparency and density

No-contact, non-destructive measurement

Less time and labor intensive than sieve analysis

Wide dynamic measuring range from 0.8 µm to 8 mm (extended measuring ranges available)

Newly developed optical system with ultra-strong LEDs for highest resolution and exceptional depth of sharpness

Features

. .
Measuring principle Dynamic Image Analysis (ISO 13322-2)
Measuring range Standard0.8 µm to 8 mm10 µm to 8 mm (gravity dispersion)0.8 µm to 5 mm (air pressure dispersion)0.8 µm to 1 mm (wet dispersion)extended measuring ranges
Type of analysis dry and wet analysis
Measuring time ~ 1 to 3 min (depends on desired measuring statistics)
Number of cameras 2
Sample volume < 20 mg - 500 g (depends on sample type and measurement mode)
Measuring methods > 300 images/s, each with approx. 4.2 MPixel
Width of analysis area ~ 20 x 20 mm
Resolution 0.8 µm per pixel
Measurement parameters particle size (smallest diameter, length, mean diameter, etc.) particle shape (aspect ration width to length, symmetry, sphericity, convexity etc., acc. to ISO 9276-6)
Dimensions (W x H x D) ~ 850 x 580 x 570 mm
Weight (Measuring unit) ~ 50 kg
Operating unit Quad Core PC incl. Windows 10, monitor, keyboard and mouse, network card, PC interface cards for hardware communication, evaluation software

Function Principle

The CAMSIZER X2 makes use of the principle of digital image processing. The patented principle is reasonably simple: Dispersed particles travel in front of two bright, pulsed LED light sources. Two digital cameras are used for capturing the shadows of the particles.

One camera is optimized to examine the small particles with high resolution, the other camera for identifying the big particles with a good statistic, that means large field of view. Each camera is illuminated by one LED with optimized brightness, field of view and pulse length. A user-friendly software is used for analyzing the shape and size of each particle, and it finally calculates the respective distribution curves in real-time.

Particle X-Plorer Software Module - RETSCH TECHNOLOGY

Particle Analyzer CAMSIZER X2 - RETSCH TECHNOLOGY

[Optical Particle Measurement System - CAMSIZER® X2]相关推荐
Custom Scientific, Inc.

Custom Scientific, Inc.

We are world-renowned for our custom and off-the-shelf optics and interference filters. Scientist……...

Translume Inc.

Translume Inc.

Translume is the acknowledged leader in micromachining fused silica (amorphous silicon dioxide) g……...

Coolon Pty Ltd

Coolon Pty Ltd

Coolon is a multi award-winning Victorian advanced electronics manufacturer, specializing in prem……...

今日仪器
  1. Applegate Marketplace Ltd.

    Applegate Marketplace Ltd.

    Applegate is the UK's best known and longest established internet directory for industry, manufacturing and technology in the UK and Ireland. It is the largest and most comprehensive directory……

    代理品牌 2025-06-14

  2. Dynamic Characterization of Encapsulated MEMS

    Dynamic Characterization of Encapsulated MEMS

    The MEMS industry has been benefiting extensively from non-contact vibration testing (vibrometry) in troubleshooting, FE model correlation and performance validation of critical components in the m……

    仪器产品 2025-06-14

  3. Lachlan Star Limited

    Lachlan Star Limited

    The Company’s current activities involve resource exploration. Lachlan Star has recently announced an Option Agreement to acquire a 75% interest in the prospective Koojan Cu-Ni-PGE Project in……

    代理品牌 2025-06-14

返回顶部小火箭