Aadco Medical Inc.
Since 1985, AADCO Medical, Inc. has specialized in the design and manufacture of Medical Imaging ……...
The NanoRacer® High-Speed AFM denotes a quantum leap in quantitative imaging abilities. The dynamic biological processes’ real-time visualization of nanometer resolution is simple.
The NanoRacer paves the way for a world of new and stimulating chances for Life Science applications. This allows scientists to gain in-depth knowledge of complicated biological systems and molecular mechanisms, in a way that has not been possible so far.
Benefits
50 fps and 5000 lines/second
Small cantilever capability is available for the lowest force imaging and least sample damage.
Highest scan speeds for progressed force mapping
Atomic defect resolution
Real-time visualization of dynamic biological processeswith nm resolution.
Comprehending complicated molecular dynamics and biological systems.
Automation with fast results
Outstanding performance, cutting-edge engineering, and stability.
Users can completely perform the automated setup.
Advanced data analysis.
Features
NanoRacer offersa new chapter in high-speed atomic force microscopy (AFM), providing an in-depth understanding ofmolecular dynamics in real-time at 50 frames and true 5000 lines per second.
The NanoRacer unveils a world of new and interesting chances for Life Science applications. This allows scientists to gain an elaborate insight into complicated biological systems and molecular mechanisms, in a method that is notpossible so far.
Features include:
Single-molecule binding behavior
Enzyme activity monitoring
Protein/protein interactions
Virus and bacteria morphology and dynamics
Availability of motor protein and membrane trafficking dynamics
Dynamics available in two-dimensional protein assemblies
Assembly and disassembly processes of protein structures
DNA origami assembly
DNA origami nanostructures containing 5 biotin binding sites on mica, imaged in fluid with streptavidin presence in closed-loop at 50 frames and 5000 lines/sec. Image Credit: Bruker Nano GmbH - JPK BioAFM
So many things are still hidden in biological molecules. To uncover their unexplored secrets, there is a true need to directly observe individual molecules during their functional activity. The NanoRacer is the fastest commercial, high-speed AFM available, enabling their direct observation in real-time.
Toshio Ando, Professor, Nano Life Science Institute (WPI-NanoLSI), Kanazawa University
Ando stated, “A lot of innovative ideas have been incorporated for easy operation and high performance, and it is my utmost wish that many researchers will use the NanoRacer to reach their goals and make exciting discoveries.”
Image Credit: Bruker Nano GmbH - JPK BioAFM
Outstanding Resolution, Renowned Stability, Remarkable Accuracy
Imaging atomic defects and sub-molecular resolution are routine. The NanoRacer consists of the least noise levels of any commercial AFM system available due to the high-precision electronics and improved precision positioning sensors present in every axis.
The NanoRacer shows the pioneering work of Bruker’s BioAFM team in integrating technological progress with user-friendliness, proven stability, and sensitivity.
Atomic resolution of calcite crystal step edge, imaged in fluid, 3D topography 15 × 9 nm² [1], zoom 4 × 4 nm² [2]. Image Credit: Bruker Nano GmbH - JPK BioAFM
Availability of small cantilevers and lowest forces for minimum sample damage
Advanced algorithms can be performed for scanner control and feedback
Minimum force drift available for long-term experiments
Cutting-edge, high-speed power amplifier provided for ideal scanner drive
Closed-loop scanning on all axes with minimal noise levels for the greatest precision
Infrared laser photothermal excitation optionfor clean cantilever drive, simple setup, and reduced perturbance of sensitive samples
Greatest bandwidth digital electronics, with the lowest noise, for utmost performance
Individual DNA molecules imaged in fluid on mica+PLO in closed loop. Sequences [4] + [5] are imaged at 50 frames/sec. Click on the image to watch the video. Image Credit: Bruker Nano GmbH - JPK BioAFM
Discover a New User Experience - A Complete System Designed for Convenience
Simple sample and probe loading
Transportable sample carrier for comfortable sample preparation on the bench
Fluid exchange through direct injection
Newly developed three-port liquid cell available for photothermal excitation
No calibration is required as a result of the closed-loop scanner design
Simple navigation can be carried out with a combined camera for locating areas of interest on the sample
Probe exchange can be done in just a few minutes
Image Credit: Bruker Nano GmbH - JPK BioAFM
The NanoRacer provides anew chapter in high-speed AFM and relegates complex, laborious procedures to the past. Produced with the user in mind, thestrong and reliable design, with a host of new features, makes the NanoRacer user-friendly, even for newcomers to AFM.
All components have been developed for comfortable handling, from sample preparation to completely motorized and automatic optical alignment. The smooth handling enables simple data collection and quick outcomes. A brief time-to-data is crucial for obtaining dynamic outcomes on active single-molecule samples.
Improved drift compensation
Automated cantilever alignment can be performed
Automated calibration of cantilever spring constant
Availability of internal camera with autofocus
Automated photothermal laser alignment option is available
Seamless handling for preparation and imaging with the transportable sample scanner. Prepare the sample conveniently on the bench and load into the NanoRacer to image. Image Credit: Bruker Nano GmbH - JPK BioAFM
Key Features
Greatest imaging speed of 50 frames and true 5000 lines per second with excellent resolution
Availability of intuitive V7 software for proven user-friendliness
Newly developed scanner unit and high-speed head
Improved for small and medium-sized cantilevers
Cutting-edge electronics available
Strong concentric design for maximum stability
Optional with Bruker’s exclusive PeakForce Tapping
Automated cantilever alignment is possible
Image Credit: Bruker Nano GmbH - JPK BioAFM
Applications
High-Speed Imaging Data Gallery
Bruker’s BioAFMs enable life science and biophysics scientists to advance their investigations in mechanobiology, cell dynamics, cell mechanics and adhesion, cell-cell and cell-surface interactions, and cell morphology.
Since 1985, AADCO Medical, Inc. has specialized in the design and manufacture of Medical Imaging ……...
Analytik Jena has introduced the ICP-MS solutions of the PlasmaQuant MS series that benefit both ……...
Biolin Scientific is a leading Nordic instrumentation company with roots in Sweden and Finland. O……...
With international offices and 35 years of experience as a trusted provider of thermal spray solu……...
Ressources d’Arianne Inc. is an active mining exploration company in North America, mostly ……...
Locatedin New York, Brookhaven Instruments offers superior instrumentation for nanoparticle, prot……...
Teikuro Since 1987 providing Hard Chrome Surface Treatment to the North American automotive stamping industry. In addition to automotive stamping dies, our Hard Chrome product is now being utilized……
As the birthplace of public higher education in America, the University of Georgia is inspiring the next generation of entrepreneurs, researchers, and informed citizens who will change the world. F……
Scope Technology Inc. has been in business since 1994 manufacturing affordable Industrial Fiberscopes, Videoscopes and Remote Visual Inspection Devices. We manufacture stock items and we also produ……