Process FT-NIR Analyzer - TALYS ASP500 Series
The ASP500 series TALYS is a fiber optics based industrial FT-NIR analyzer that has been exclusiv……...
Beckman Coulter Life Science’s Multisizer 4e Coulter Counter is a multifaceted system for particle counting and characterization.
Using the Coulter principle, the system detects particles through electrical zone sensing, irrespective of the nature or the optical properties of the particle. Thanks to this feature, it is theperfect tool for the detection and counting of an extensive range of particles, for example:
Yeast
Mammalian cells
Large protein aggregates
Bacteria
Abrasives
Cell aggregates
Toner particles
Spheroids
Features
Versatility
The system features aperture sizes with a diameter ranging from 10 to 2000 µm to fulfill the existing and future demands.
The data overlay capability and multiple aperture options provided in the system enable the analysis of complex samples over wide particle size distribution.
Sample Detection
The system is best suited for non-biological or biological samples.
Materials in non-aqueous or aqueous solvents can be analyzed.
Particles can be detected irrespective of type or optical properties of the material.
Rapid Particle Counting
Particles with a diameter ranging from 0.2 to 1600 µm can be detected and counted
Typical sampling rates of up to 10,000 counts per second
Sample volumes as low as 5 mL
Data Management
Users can store and re-analyze digital pulse data as needed
Range of calibration beads and V-check validation controls offered
Software compliant with CFR 21 Part 11 provided for audit control and security
Specifications
Source: Beckman Coulter Life Sciences
. | . |
---|---|
Performance | Aperture current accuracy ± 0.4% of setting; Polarity error less than 0.5% |
Industry Standards | 21 CFR Part 11 |
Sample Volume Range | 4 - 400 mL |
Particle Size Analysis Range | 0.20|1,600.00|μm in diameter |
Sample Volume | от 0,004 мкм3 до 2,145 x 109 Ф∧ и∧и мкм3 |
Fluid Compatibility | All aqueous and non-aqueous electrolyte solutions devised for use with aperture technology are suitable for use with the Multisizer 4e. Electrolytes should be compatible with glass, fluoropolymers, fluoroelastomers, and stainless steel. |
Linearity | Linearity for 2% - 60% of aperture diameter: ±1% for diameter, ±3% for volume |
Aperture Diameter Range | 10 µm to 2000 µm apertures (nominal diameter) |
Digital Pulse Processor | Proprietary high-speed digitization of the signal |
Volumetric Mode | Continuously selectable from 50 µL-2000 µL |
Volumetric Pump Accuracy | >99.5% |
Item Specifications Referenced | B43905 |
The ASP500 series TALYS is a fiber optics based industrial FT-NIR analyzer that has been exclusiv……...
New-Form Tools was founded in 1985, in Milverton, Ontario, Canada. In 1994, the company purchased……...
We are an international leader in the design and manufacture of intralogistics systems for convey……...
ZX Lidars provides hub height and turbine mounted accurate wind measurements with Lidar, for win……...
Solvay Solexis is a leader in Fluorinated Materials. Fluorine-based materials, while offering a b……...
At Arden Photonics we specialise in instrumentation for the measurement of a wide range of proper……...