Optotek Medical
Mission Statement Our company’s strategy is to continually develop new solutions, applicati……...
Class-leading and proven in its performance, AutoPore V sets a new standard for operational safety.
Capable of measuring pore sizes ranging from as small as 3 nm to as large as 1100 µm.
High-resolution analysis is accessible for macroporous and mesoporous materials, facilitating stringent quality control and offering comprehensive data for research, covering both intrusion and extrusion.
Flexible reporting options are configurable to maximize the utility of the collected data.
Recent enhancements prioritize enhancing operator safety.
Multiple analysis modes are provided for swift or detailed analyses, emphasizing either speed or resolution based on user requirements.
Various configurations are available to customize the instrument according to user preferences, including the number of analysis ports and operating pressure range.
Adheres to the specifications outlined in ASTM Test Methods D4284, D4404, and D6761, as well as ISO 15901-1 and USP <267>.
Description
Class Leading, Proven Performance
The analysis technique employed in mercury porosimetry relies on the intrusion of mercury into a porous structure under highly controlled pressures. In addition to providing rapidity, precision, and an extensive measurement range, mercury porosimetry enables the calculation of various sample properties, including pore size distributions, total pore volume, total pore surface area, median pore diameter, and sample densities (both bulk and skeletal).
The AutoPore V Series Mercury Porosimeters can determine a broader pore size distribution more accurately and rapidly thanalternative methods.
This instrument is equipped with enhanced safety features. It introduces new options for data reduction and reporting, providing additional insights into the pore geometry and the fluid transport characteristics of the material.
Features and Benefits
Nineteen standard penetrometer sizes and configurations enable the analysis of diverse sample sizes and shapes
Delivers swift and comprehensive intrusion and extrusion analysis across an extensive spectrum of pore sizes
Sets a new benchmark in operator safety thanks to theintroduction of enhanced safety features
Offers scanning and equilibration modes of operation for rapid or more detailed analyses, respectively
Incorporates user-defined advanced reporting capabilities through Python scripts
Utilizes MicroActive software, allowing for quick adjustments to reporting ranges
Image Credit: Micromeritics Instrument Corporation
Specification
Source: Micromeritics Instrument Corporation
Electrical | |
---|---|
Voltage | 100/120/220/240 VAC ± 10 % |
Frequency | 50 or 60 Hz |
Power | 500 VA maximum |
Gas | |
Nitrogen or other clean, dry gas at 50 psig (345 kPa) | |
High-Pressure Model 9600 and 9605 | |
Measurement | From atmospheric pressure to 33,000 psia |
Resolution | 0.165 psia from 3,300 psia to 33,000 psia |
Transducer Accuracy | ±0 .1 % of full scale (transducer manufacturer’s specifications) |
Transducer Hysteresis | 0.05 % of full scale |
Pore Diameter Range | 6 to 0.005 μm |
Servo Control Precision | 0.5 % of target, min 5 psia, no overshoot |
High-Pressure Model 9610 and 9620 | |
Measurement | From atmospheric pressure to 60,000 psia |
Resolution | 0.03 psia from atmospheric pressure to 60,000 psia |
Transducer Accuracy | ± 0.1 % of full scale (transducer manufacturer’s specifications) |
Transducer Hysteresis | 0.05 % of full scale |
Pore Diameter Range | 6 to 0.003 μm |
Servo Control Precision | 0.5 % of target, min 5 psia, no overshoot |
Intrusion | |
Resolution | Better than 0.1 all |
Accuracy | ± 1 % of maximum penetrometer stem volume |
Low Pressure | All Models |
Measurement | 0.2 to 50 psia (345 kPa) |
Resolution | 0.00025 psi |
Pore Diameter Range | 1100 to 3.6 μm |
Transducer Accuracy | ± 1 % of full scale (transducer manufacturer’s specifications) |
Servo Control Precision | 1 % of target, min, 0.05 psia, no overshoot |
Penetrometers | |
Stem Intrusion Volumes | 0.38, 1.1, 1.7, 3.1, and 3.9 cc |
Sample Size | Maximum: a cylinder 2.54 cm diameter × 2.54 cm long (1 in. diameter × 1 in. long) |
Physical | |
Height | 143 cm (56.25 in.) |
Width | 54.3 cm (21.38 in.) |
Depth | 78 cm (30.75 in.) |
Weight | 250 kg (550 lb) |
Technology
Operational Advantages
Capable of measuring pore diameters within the range of 0.003 upto 1100 µm (Calculated with an initial filling pressure of 0.2 psia or 0.00128 MPa)
Controlled pressure can incrementally increase in fine increments of 0.05 psia, ranging from 0.2 to 50 psia, allowing for detailed data collection in the macropore region
Operates in scanning mode and time- or rate-of-intrusion equilibrated modes
Real-time diagnostics offer insight into potential issues before they reach a critical point or impact analytical results
High-resolution (sub-microliter) measurement of intrusion/extrusion volumes ensures extraordinary precision, enabling the establishment of tighter sample specifications, improved production processes, and the generation of high-quality research data
Features enhanced linear motion for the closure of the high-pressure chamber
Collects exceptionally high-resolution data, surpassing 0.1 µL for both mercury intrusion and extrusion volumes
Design Advantages
Equipped with four low-pressure and two high-pressure ports to enhance sample throughput
Enhanced safety features minimize the risk of mercury spills and operator exposure
Available in models with pressure capacities of 33,000 psia or 60,000 psia
Quick-scan mode enables a continuous pressure increase approximatingequilibrium for faster screening
Features a low-noise, high-pressure generating system
Provides a choice of pressure ramping methods, allowing selection between scanning mode for high-speed or on-demand results, and equilibration mode for more precise results with greater detail
Includes a temperature sensor for automatically calculating mercury density used in penetrometer calibrations
MicroActive software enables interactive data manipulation, custom report definition, and the rapid attainment of analytical results
Offers a selection of correction routines for baseline (automatic, differential, or manual), ensuring greater accuracy by addressing compressibility and thermal effects resulting from high-pressure
Compensates for material compression under high-pressure analysis
A New Benchmark for Operational Safety
Image Credit: Micromeritics Instrument Corporation
Configuration
Four Models
The AutoPore V comes in four models that are designed to align with the specific requirements of individual quality assurance and research laboratories.
Source: Micromeritics Instrument Corporation
9605 | 9620 | 9600 | 9610 | |
---|---|---|---|---|
Low Pressure | 4 ports | 4 ports | 2 ports | 2 ports |
High Pressure | 2 ports @ 33,000 psia | 2 ports @ 60,000 psia | 1 port @ 33,000 psia | 1 port @ 60,000 psia |
Penetrometers
Partial List
Source: Micromeritics Instrument Corporation
Model# | Size | Stem Volume | Medium | Typical Use |
---|---|---|---|---|
01 | 15 cc | 0.392 | Solid | refractories, low-porosity solid rocks/cores, low-porosity solid polymers |
02 | 15 cc | 0.392 | Powder | low-porosity powders, gravel, irregular rock shapes |
03 | 15 cc | 1.131 | Solid | medium-porosity rocks/cores, solid materials |
04 | 15 cc | 1.131 | Powder | medium-porosity rocks, solid materials, fumed silica |
07 | 5 cc | 0.392 | Solid | paper, flexible polymer/membrane sheets, pharma tablets |
08 | 5 cc | 0.392 | Powder | silicates, catalysts, powders (general use), pharma powders |
09 | 5 cc | 1.131 | Solid | medium/high-porosity sheet-form materials (paper, polymer, etc.), pharma tablets |
10 | 5 cc | 1.131 | Powder | silica-alumina, silicates, zeolites, catalysts, powders (general use), pharma powders |
14 | 3 cc | 0.412 | Powder | powders (general use), materials with low quantity available |
24 | 15 cc | 3.263 | Solid | high-porosity rock/cores, low-density/high-porosity foams |
25 | 15 cc | 4.185 | Solid | high-porosity material with large volume |
Accessories
Penetrometer Rack
Image Credit: Micromeritics Instrument Corporation
For secure storage and transportation of penetrometers to prevent breakage and avoid unnecessary replacements.
Mercury QuikVac
Image Credit: Micromeritics Instrument Corporation
Mercury QuikVac offers a cost-effective solution for promptly managing mercury spills. The device is specifically designed to efficiently capture elusive mercury droplets and small mercury-contaminated particulate matter.
The collected mercury is stored in a 250 mL recovery vessel,and a replaceable 0.3 – 0.5 micron activated carbon filter ensures that the device releases clean and safe air.
Consumables and Supplies
Source: Micromeritics Instrument Corporation
Part Number | Description | Comments |
---|---|---|
950-61701-00 | Penetrometer Set, 15 cm3 Solid, 0.366 cm3 intrusion volume | Includes 1 each penetrometer 920-61701-01 and closure set 950-25832-00 |
950-61702-00 | Penetrometer Set, 15 cm3 Powder, 0.366 cm3 intrusion volume | Includes 1 each penetrometer 920-61702-01 and closure set 950-25832-00 |
950-61703-00 | Penetrometer Set, 15 cm3 Solid, 1.06 cm3 intrusion volume | Includes 1 each penetrometer 920-61703-01 and closure set 950-25832-00 |
950-61704-00 | Penetrometer Set, 15 cm3 Powder, 1.06 cm3 intrusion volume | Includes 1 each penetrometer 920-61704-01 and closure set 950-25832-00 |
950-61705-00 | Penetrometer Set, 15 cm3 Solid, 1.72 cm3 intrusion volume | Includes 1 each penetrometer 920-61705-01 and closure set 950-25832-00 |
950-61706-00 | Penetrometer Set, 15 cm3 Powder, 1.72 cm3 intrusion volume | Includes 1 each penetrometer 920-61706-01 and closure set 950-25832-00 |
950-61707-00 | Penetrometer Set, 5 cm3 Solid, 0.366 cm3 intrusion volume | Includes 1 each penetrometer 920-61707-01 and closure set 950-25831-00 |
950-61708-00 | Penetrometer Set, 5 cm3 Powder, 0.366 cm3 intrusion volume | Includes 1 each penetrometer 920-61708-01 and closure set 950-25831-00 |
950-61709-00 | Penetrometer Set, 5 cm3 Solid, 1.06 cm3 intrusion volume | Includes 1 each penetrometer 920-61709-01 and closure set 950-25831-00 |
950-61710-00 | Penetrometer Set, 5 cm3 Powder, 1.06 cm3 intrusion volume | Includes 1 each penetrometer 920-61710-01 and closure set 950-25831-00 |
950-61711-00 | Penetrometer Set, 5 cm3 Solid, 1.72 cm3 intrusion volume | Includes 1 each penetrometer 920-61711-01 and closure set 950-25831-00 |
950-61712-00 | Penetrometer Set, 5 cm3 Powder, 1.72 cm3 intrusion volume | Includes 1 each penetrometer 920-61712-01 and closure set 950-25831-00 |
950-61713-00 | Penetrometer Set, 3 cm3 Solid, 0.387 cm3 intrusion volume | Includes 1 each penetrometer 920-61713-01 and closure set 950-25831-00 |
950-61714-00 | Penetrometer Set, 3 cm3 Powder, 0.387 cm3 intrusion volume | Includes 1 each penetrometer 920-61714-01 and closure set 950-25831-00 |
950-61715-00 | Penetrometer Set, 3 cm3 Solid, 1.12 cm3 intrusion volume | Includes 1 each penetrometer 920-61715-01 and closure set 950-25831-00 |
950-61716-00 | Penetrometer Set, 3 cm3 Powder, 1.12 cm3 intrusion volume | Includes 1 each penetrometer 920-61716-01 and closure set 950-25831-00 |
950-61720-00 | Penetrometer Set, 3 cm3 Solid, 0.90 cm3 intrusion volume | Includes 1 each penetrometer 920-61720-01 and closure set 950-25831-00 |
950-61724-00 | Penetrometer Set, 15 cm3 Solid, 3.01 cm3 intrusion volume | Includes 1 each penetrometer 920-61724-01 and closure set 950-25832-00 |
950-61725-00 | Penetrometer Set, 15 cm3 Solid, 3.86 cm3 intrusion volume | Includes 1 each penetrometer 920-61725-01 and closure set 950-25832-00 |
920-61701-01 | Penetrometer, 15 cm3 Solid, 0.366 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25832-00 |
920-61702-01 | Penetrometer, 15 cm3 Powder, 0.366 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25832-00 |
920-61703-01 | Penetrometer, 15 cm3 Solid, 1.06 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25832-00 |
920-61704-01 | Penetrometer, 15 cm3 Powder, 1.06 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25832-00 |
920-61705-01 | Penetrometer, 15 cm3 Solid, 1.72 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25832-00 |
920-61706-01 | Penetrometer, 15 cm3 Powder, 1.72 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25832-00 |
920-61707-01 | Penetrometer, 5 cm3 Solid, 0.366 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61708-01 | Penetrometer, 5 cm3 Powder, 0.366 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61709-01 | Penetrometer, 5 cm3 Solid, 1.06 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61710-01 | Penetrometer, 5 cm3 Powder, 1.06 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61711-01 | Penetrometer, 5 cm3 Solid, 1.72 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61712-01 | Penetrometer, 5 cm3 Powder, 1.72 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61713-01 | Penetrometer, 3 cm3 Solid, 0.387 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61714-01 | Penetrometer, 3 cm3 Powder, 0.387 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61715-01 | Penetrometer, 3 cm3 Solid, 1.12 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61716-01 | Penetrometer, 3 cm3 Powder, 1.12 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61720-01 | Penetrometer, 3 cm3 Solid, 0.90 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25831-00 |
920-61724-01 | Penetrometer, 15 cm3 Solid, 3.01 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25832-00 |
920-61725-01 | Penetrometer, 15 cm3 Solid, 3.86 cm3 intrusion volume | Penetrometer glassware only; use with closure set 950-25832-00 |
950-33605-00 | Penetrometer Closure Kit for 3cm3 and 5 cm3 Penetrometers | Includes six 3 cm3 and 5 cm3 penetrometer closure sets, 950-25831-00, and closure nut holder 950-09802-00 and seal wrench 950-09803-00 |
950-33606-00 | Penetrometer Closure Kit for 15 cm3 Penetrometers | Includes six 15 cm3 penetrometer closure sets, 950-25832-00, and closure nut holder 950-09802-00 and seal wrench 950-09803-00 |
950-25831-00 | Closure Set for 3 cm3 and 5 cm3 Penetrometers | Includes 1 each closure nut 950-25831-01 and closure nut 950-25831-01 for 3 cm3 and 5 cm3 penetrometers |
950-25832-00 | Closure Set for 15 cm3 Penetrometers | Includes 1 each closure nut 950-25832-01 and closure nut 950-25832-01 for 15 cm3 penetrometers |
950-25831-01 | Closure Nut for 3 cm3 and 5 cm3 Penetrometers | Penetrometer closure nut for all 3 cm3 and 5 cm3 penetrometers |
950-25831-02 | Closure Seal for 3 cm3 and 5 cm3 Penetrometers | Penetrometer closure seal for all 3 cm3 and 5 cm3 penetrometers |
950-25832-01 | Closure Nut for 15 cm3 Penetrometers | Penetrometer closure nut for all 15 cm3 penetrometers |
950-25832-02 | Closure Seal for 15 cm3 Penetrometers | Penetrometer closure seal for all 15 cm3 penetrometers |
950-09802-00 | Penetrometer Closure Nut Holder | Used to hold penetrometer closure nut while tightening before analysis, and while loosening after analysis |
950-09803-00 | Penetrometer Closure Seal Wrench | Used to tighten penetrometer closure seal before analysis, and loosen seal after analysis |
950-25831-03 | Spacer for 3 cm3 and 5 cm3 Penetrometers | Used to properly position penetrometer while in low-pressure port to ensure connection to banana plug-in capacitance detector assembly |
942-25863-00 | Spacer for 15 cm3 Penetrometers | Used to properly position penetrometer while in low-pressure port to ensure connection to banana plug-in capacitance detector assembly |
962-25807-00 | Penetrometer Safety Enclosure | Holds penetrometer securely in place while viewing penetrometer installed into low-pressure port |
950-25822-00 | Penetrometer Weighing Support | Holds penetrometer assembly while weighing |
950-25820-00 | Rack for Penetrometer Storage | Securely holds empty penetrometers to help prevent breakage when not in use |
962-25827-00 | Rack for Filled Penetrometers | Holds filled penetrometers upright to facilitate movement between instrument and balance when determining Assembly Mass |
930-54601-00 | Cleaning Brush for Penetrometer with 0.4 cm3 Stem Volume | Used to clean inside 0.4 cm3 penetrometer stems |
930-54602-00 | Cleaning Brush for Penetrometer with 1.1 cm3 Stem Volume | Used to clean inside 1.1 cm3 penetrometer stems |
930-54603-00 | Cleaning Brush for Penetrometer with 1.8 cm3, 3.3 cm3, and 4.2 cm3 Stem Volume | Used to clean inside 1.8 cm3, 3.3 cm3, and 4.2 cm3 penetrometer stems |
Routine Operating Supplies | ||
004-16007-00 | Apiezon Type H High Vacuum Grease | Used to seal between penetrometer and closure nut |
920-16001-00 | High-Pressure Fluid, 1 L | Used to fill high-pressure chamber during analysis; not used in the hydraulic pump |
008-16045-00 | Silicone High Vacuum Grease | Used to lubricate low-pressure seals; apply small amount to penetrometer stems or low-pressure filler rods |
004-16011-00 | Hydraulic Pump Oil, Synthetic 15W-50 Grade | Used in the hydraulic pump that generates pressure for the high-pressure system; not used in the high-pressure port |
004-16004-01 | Triple Distilled Mercury | Ships as hazardous material; importation is limited by some countries. Check with Micromeritics' Representative for more details. |
942-25823-00 | Syringe, 50 mL |
For adding high-pressure fluid to the chamber, and for removing it from the chamber |
962-33601-00 | Operating Supplies | Includes one Liter of high-pressure fluid 920-16001-00, two unmodified banana plugs 003-21273-00, four modified banana plugs 930-25849-00, valve spanner 004-54039-00, mercury vapor filter 962-27000-00, and a package of 10 mercury vapor detection tubes |
962-33602-00 | Extended Operating Supplies | Includes Apiezon vacuum grease 004-16007-00, two Liters of high pressure fluid 920-16001-00, four unmodified banana plugs 003-21273-00, ten modified banana plugs 930-25849-00, valve spanner 004-54039-00, three mercury vapor filters 962-27000-00, and package of 10 mercury vapor detection tubes 962-29601-00 |
Routine Maintenance Supplies | ||
003-21273-00 | Banana Plug for Capacitance Detector Assemblies, unmodified | Replacement banana plugs for low-pressure and high-pressure capacitance detector assemblies |
922-09808-00 | Banana Plug Tool | For removal and replacement of banana plugs for capacitance detector assemblies and high-pressure feedthrough assemblies |
920-33616-00 | High-Pressure Vessel Maintenance Kit | Includes two each backup rings 004-25297-00, high-pressure seals 922-25890-00, O-rings for vent valve 004-25034-00, and modified banana plugs 930-25849-00, as well as six penetrometer contacts 930-25817-00 and instruction sheet |
922-33607-00 | High-Pressure Chamber Plug Seal Kit | Includes two each backup rings 004-25297-00 and high-pressure seals 922-25890-00, as well as an instruction sheet |
004-25297-00 | Backup Ring for High-Pressure Chamber Plug Seal | Replacement high-pressure chamber plug seal backup ring |
922-25890-00 | High-Pressure Chamber Plug Seal | Replacement high-pressure chamber plug seal |
004-25034-00 | O-ring for High-Pressure Chamber Vent Valve | Replacement O-ring for vent valve located on top of the high-pressure chamber |
930-25817-00 | Penetrometer contact for High-Pressure Chamber | Replacement penetrometer contact for high-pressure chamber plug |
930-25849-00 | Banana Plug for High-Pressure Feedthrough Assemblies, modified | Replacement banana plugs for high-pressure feedthrough assemblies in the bottom of the high-pressure ports |
962-33002-00 | Mercury Reservoir Cap Assembly | Replacement cap for mercury reservoir filling port |
004-25652-00 | O-ring for Mercury Reservoir Cap | Replacement O-ring for mercury reservoir filling port |
942-25600-00 | Cover for Spilled Mercury Containment Dish | Replacement cover for mercury spill containment dish |
003-51123-00 | 6.25 Amp Fuse, 3AG Slo-Blo 250 VAC | Replacement fuse for 100 to 120-volt installations |
003-51134-01 | 5 Amp Fuse, 5x20 mm Slo-Blo 250 VAC CE | Replacement fuse for 220 to 240-volt installations |
003-63801-01 | Ethernet Cable | Replacement Ethernet cable for connection of AutoPore to controlling computer |
004-54039-00 | Spanner for Solenoid Valves | Spanner to facilitate replacement of solenoid valve plungers |
930-17801-00 | Penetrometer Simulator, 82 pF | Penetrometer simulator for use when verifying calibration of capacitance detector system, 82 pF |
930-17801-01 | Penetrometer Simulator, 150 pF | Penetrometer simulator for use when verifying calibration of capacitance detector system, 150 pF |
930-17801-05 | Penetrometer Simulator, 15 pF | Penetrometer simulator for use when verifying calibration of capacitance detector system, 15 pF |
Reference Material and Reference Volume Capsules for Operational Verification | ||
004-16822-00 | Reference Material for Total Pore Volume and Median Pore Diameter | Reference material for operational verification |
940-34801-00 | Mercury Reference Volume Kit | Includes two small capsule assemblies 940-34800-00, 2 large capsule assemblies 940-34800-01, 25 replacement O-rings 004-25646-00, one package each of 8 µm membranes 940-25600-00 and 3 µm membranes 940-25600-01, storage case and instruction manual |
940-34800-00 | Small Mercury Reference Capsule Assembly | Reference volume capsule assembly, nominal 0.24 mL capacity |
940-34800-01 | Large Mercury Reference Capsule Assembly | Reference volume capsule assembly, nominal 0.80 mL capacity |
940-14800-00 | Reference Capsule Retaining Clip | Replacement retaining clip for reference volume capsule assemblies |
004-25646-00 | Reference Capsule O-ring | Replacement O-ring for reference volume capsule assemblies |
940-25600-00 | Reference Capsule 8 µm Member, Package of 100 | Replacement 8 µm membrane for reference volume capsule assemblies |
940-25600-01 | Reference Capsule 3 µm Member, Package of 100 | Replacement 3 µm membrane for reference volume capsule assemblies |
Mercury Safety Accessories | ||
090-00000-00 | QuikVac Mercury Clean-up Accessory | Mercury spill vacuum and containment accessory, capable of holding up to 250 mL of recovered mercury, with replaceable activated charcoal filter |
942-33021-00 | Exhaust Fan Kit | Optional kit to pull fresh air across mercury reservoir and then exhaust it to the rear of the instrument; port on the rear of instrument needs to be ducted properly to room ventilation system that is capable of handling mercury vapors |
962-25859-00 | Mercury Vapor Filter Assembly | Replacement mercury vapor filter for vacuum pump exhaust |
962-29600-00 | Mercury Vapor Detection Pump | Replacement mercury vapor detection pump for testing environment for mercury vapors using disposable mercury vapor detection tubes |
962-29601-00 | Mercury Vapor Detection Tube, Package of 10 | Replacement mercury vapor detection tubes for use with mercury vapor detection pump |
004-32031-00 | Low-Pressure Mercury Drip Tray | Replacement low-pressure mercury drip tray |
Low-Pressure Vacuum System Replacement Items and Supplies | ||
062-62801-11 | Vacuum Pump, 100 to 120 VAC | Replacement vacuum pump for evacuation of low-pressure system, for 100 to 120 VAC installations |
062-25801-23 | Vacuum Pump, 220 to 240 VAC | Replacement vacuum pump for evacuation of low-pressure system, for 220 to 240 VAC installations |
004-27040-00 | Vacuum Pump Exhaust Filter | Replacement exhaust filter for low-pressure vacuum pump |
004-16003-01 | Vacuum Pump Oil, 1L | Vacuum oil for low-pressure vacuum pump |
004-25630-00 | Centering Ring NW 16 | Replacement centering ring for connection to vacuum pump exhaust port |
004-25509-00 | Clamp NW 10/16 | Replacement clamp for connection to vacuum pump exhaust port |
Gas Supply Accessories | ||
004-62200-58 | Gas Regulator, 2-stage 100 psig outlet, CGA 580 gas cylinder fitting | Regulator for compressed gas supply to low-pressure system |
230-02001-00 | Gas Inlet Line, 1/8 inch OD x 6 feet L | Gas inlet line for compressed gas supply to low-pressure system |
004-25549-00 | Reducing Union, 1/4 inch to 1/8 inch | Reducing union to connect gas inlet line 230-02001-00 to gas regulator 004-62200-58 |
004-33601-00 | Two-outlet Expansion Kit for Gas Regulator | Expansion kit to allow use of one gas cylinder for multiple instruments |
004-33602-00 | Pressure Relief Kit for Gas Regulator | Used to prevent over-pressurization of gas regulator outlet |
Software and Operator's Manual | ||
962-20800-00 | AutoPore V Software | Latest version of AutoPore V operating software |
962-42800-00 | AutoPore V Operator's Manual | Printed AutoPore Operator's Manual, with binder |
Applications
Pharmaceuticals
Porosity and surface area are significant in the purification, processing, blending, tableting, and packaging of pharmaceutical products. They also influence a drug's shelf life, dissolution rate, and bioavailability.
Ceramics
The curing and bonding of greenware are impacted by pore area and porosity. This is crucial fordetermining the strength, texture, appearance, and density of the finished goods.
Adsorbents
Understanding pore area, total pore volume, and pore size distribution is crucial for maintaining quality control in industrial adsorbents and in the development of separation processes. Porosity and surface area characteristics play a key role in determining the selectivity of an adsorbent.
Catalyst
Production rates are influenced by the active surface area and pore structure of catalysts. By restricting the pore size, only molecules of specific sizes are permitted to enter and exit, creating a selective catalyst that predominantlyproduces the desired product.
Aerospace
The weight and functionality of heat shields and insulating materials are influenced by their surface area and porosity.
Fuel Cells
To achieve sufficient power density, fuel cell electrodes necessitate carefully regulated porosity coupled with a high surface area.
Geoscience
Porosity holds significance in groundwater hydrology and petroleum exploration as it correlates with the quantity of liquid a structure can hold and determines how much effort will be required to extract it.
Filtration
Filter manufacturers are interested in parameters such as pore size, pore volume, pore shape, and pore tortuosity. Frequently, pore shape has a more direct impact on filtration than pore size, as it strongly correlates with filtration performance andfouling.
Construction Materials
Degradation processes in concrete, cement, and other construction materials are significantly influenced by diffusion, permeability, and capillary flow.
Paper
The porosity of the coating on print media is keyin offset printing, influencing factors such as blistering, ink receptivity, and ink holdout.
Medical Implants
The weight and functionality of heat shields and insulating materials are influenced by their surface area and porosity.
Software
Microactive for Autopore
Image Credit: Micromeritics Instrument Corporation
Intelligent, Intuitive, Interactive
MicroActive software significantly enhances functionality, convenience, diagnostics, and data interpretation, setting a new benchmark for achieving high-performance results in mercury porosimetry.
Method Wizard
Create a method using an interactive step-by-step script, simplifying the process of method creation and introducing new users to the operation of the AutoPore V.
Mercury Density Calculation
In contrast to competing systems that rely solely on mercury density at ambient temperature, the AutoPore V automatically measures the realmercury temperature, ensuring precise density calculations under operational conditions.
User-Defined Reports and Report Options
Swiftly generate tailored advanced reports to suit users’ specific requirements with Python scripting. The new reporting options also allow for automatic conversion of reports to PDF or spreadsheet formats.
Post-Analysis Parameter Change
Enables the adjustment or correction of analysis parameters (such as stem volume, maximum head pressure, and pen constant) post-analysis, eliminating the need to rerun samples due to errors.
Reverberi Method Data Reduction
Obtain data regarding the distribution of pore shapes. This method produces a three-dimensional array presenting cavity size and throat size in relation to volume.
Diagnostic Dashboard
Image Credit: Micromeritics Instrument Corporation
Real-time monitoring of essential system components in real-time for proactive maintenance and troubleshooting.
Enhanced Penetrometer Calibration
Image Credit: Micromeritics Instrument Corporation
Simplifies the calibration of penetrometers through automated calculations,volumetrically or gravimetrically.
Overlay Multiple Runs and Gas Adsorption Data
MicroActive for AutoPore V canoverlay up to 25 runs, providing the option to import pore size distributions from gas adsorption isotherms. This allows data analyzedacross the micro to macropore range to be presented in a single report.
Intelligent Data Reporting
Automatic warnings are generated when questionable data is collected.
Variety of Available Plots
Image Credit: Micromeritics Instrument Corporation
Users can access plots for pore volume, pore area, and pore size, and have the ability to calculate total intrusion volume, total pore (surface) area,average pore diameters, median pore diameters, bulk or envelope density, and apparent (skeletal) density.
Reports Include:
Summary
Tabular Report
Cumulative Volume vs Pore Size/Particle Size/Pressure
Incremental Volume vs Pore Size/Particle Size/Pressure
Cumulative Area vs Pore Size/Particle Size/Pressure
Incremental Volume vs Pore Size/Particle Size/Pressure
Differential Reference % Volume vs Pore Size/Particle Size/Pressure
Out Spec. % Volume vs Pore Size/Particle Size/Pressure
Differential Volume vs Pore Size/Particle Size/Pressure
Cumulative Volume vs Pore Size/Particle Size/Pressure
Tortuousity
Permeability
Reverberi
Advanced Report System
Log Difference Volume vs Size
Material Compressibility
Cavity to Throat Size Ratio
Fractal Dimension
Mayer-Stowe Particle Size
Mission Statement Our company’s strategy is to continually develop new solutions, applicati……...
START International has been solving customer's application needs with products serving manu……...
The Seals and Bearings business of Morgan Advanced Materials makes high performance self-lubricat……...
The GeoSpec is the industry standard NMR core analyzer, with installations in nearly every key oi……...
IXRF Systems was incorporated on October 1st, 1993 in the state of Texas. The company originally ……...
Electro Prime is the provider of corrosion, protection, assembly and machining services. We will ……...
For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……
The iXon EMCCD cameras from Andor are scientific digital cameras particularly designed to drive the absolute best from EMCCD technology across all performance parameters and specifications. The ult……
Nanalysis’ 100e benchtop NMR works on the basis of world’s most robust compact magnet platform at 100 MHz. This single-channel spectrometer has been designed for high-performance regula……