Libra Series for Enhanced Thermogravimetric Analysis

上海仪舶实验室自动化 25-01-23 13:12:52

Libra Series for Enhanced Thermogravimetric Analysis

The TG 309 Libra® Classic stands out as the top performer in affordability and functionality among the devices in the Libra® series. It is the perfect tool for quality assurance. The Classic provides a temperature range of 10 °C to 1025 °C. Furthermore, a 20-position Automatic Sample Changer (ASC) can be installed.

Get Results Faster Without a Baseline Run

A baseline run is usually carried out under identical test conditions regarding heating rate, gas type, and gas flow to guarantee accurate mass change values.

The baseline allows for the subtraction of instrument and buoyancy effects from the sample measurement by accounting for variables like heating rate, crucible type, and geometry.

When using the integrated BeFlat® baseline run for typical temperature measurements, the TG 309 Libra® eliminates the need for a separate baseline run. Tests are expedited considerably as a result.

Libra Series for Enhanced Thermogravimetric Analysis

Image Credit: NETZSCH-Gerätebau GmbH

20 Times Faster Thanks to High Heating Rates

There is a low-volume furnace on the TG 309 Libra®. It allows for quick ballistic cooling from 1025 °C to room temperature and fast heating rates of up to 200 K/min across the temperature range. This enables shorter turnaround times for analysis results, even at elevated temperatures, in minutes.

Measuring Principle

Thermogravimetric analysis (TGA) is an exact analytical method that monitors changes in a sample's mass over time and/or temperature in a defined and regulated environment, such as crucible type, flow rate, gas atmosphere, heating rate, etc.

It is capable of precisely detecting weight variations as small as a microgram. Because of its great sensitivity, even the smallest alterations to a material’s chemical and physical characteristics can be detected.

Specifications

Technical Data

Source: NETZSCH-Gerätebau GmbH

. .
Temperature range RT (10 °C) to 1025 °C at the sample
Balance resolution 50 ng
Heating and cooling rates 0.001 K/min to 200 K/min
Temperature precision 0.15 K
Wide measuring range 2000 mg
Vacuum-tightness 1 mbar
Sample crucible volume up to 350 µl
Atmospheres inert, oxidizing, reducing, static, dynamic

Libra Series for Enhanced Thermogravimetric Analysis

Image Credit: NETZSCH-Gerätebau GmbH

Compact 20-Sample ASC on a Removable Sample Carousel

The affordable TG 309 Libra® Classic can come with an optional automatic sample changer (ASC) capable of handling up to 20 samples and references. After the crucible has been safely removed from the magazine, the gripper gently places it on the sensor. A detachable ASC insert can be placed in the samples to prepare them away from the instrument.

TG 309 Libra Series

Video Credit: NETZSCH-Gerätebau GmbH

TG 309 Libra® Select

Libra Series for Enhanced Thermogravimetric Analysis

Image Credit: NETZSCH-Gerätebau GmbH

Users can examine the distinct thermal characteristics of materials and their constituent parts.

The Libra® series instrument offering the most variety is the TG 309 Libra®Select. Users can choose between temperature ranges of 10 °C to 1025 °C or up to 1100 °C. It provides exceptional balance resolution to identify even the smallest changes in a material's mass. It can also befitted with a sizable 204-position ASC (Automatic Sample Changer) and the capability to couple to gas analysis.

Get Results Faster Without a Baseline Run

A baseline run is usually carried out under identical test conditions regarding heating rate, gas type, and gas flow to guarantee accurate mass change values.

The baseline allows for the subtraction of instrument and buoyancy effects from the sample measurement by accounting for variables like heating rate, crucible type, and geometry.

When using the integrated BeFlat® baseline run for typical temperature measurements, the TG 309 Libra® usually eliminates the need for a separate baseline run. Tests are expedited considerably as a result.

Specifications

Technical Data

Source: NETZSCH-Gerätebau GmbH

. .
Temperature range RT (10 °C) to 1025 / 1100 °C at the sample
Balance resolution 20 ng
Heating and cooling rates 0.001 K/min to 200 K/min
Cooling time 12 min (1100 °C to 100 °C)
Wide measuring range 2000 mg
Vacuum-tightness << 10-1mbar
Sample crucible volume up to 350 µl
Atmospheres inert, oxidizing, reducing, static, dynamic
Automatic sample changer ASC with 204 positions optionally available

High-End 204-Sample ASC and Removable Sample Trays

The two replaceable microplate sample trays in TG 309 Libra®Select and Supreme ASC format can accommodate 96 samples each. When the samples are prepared away from the instrument, assigning them is possible. For calibration and correction purposes, an extra fixed strip can hold up to 12 empty crucibles or calibration materials of various sizes and compositions. The trays can also be used to define correction measurements using empty crucibles.

TG 309 Libra® Supreme

Libra Series for Enhanced Thermogravimetric Analysis

Image Credit: NETZSCH-Gerätebau GmbH

Researchers can study the distinct thermal properties of materials and their elements using theTG 309 Libra® Supreme - the highest-endhermobalance in the Libra® series.

It provides exceptional balance resolution to identify even the smallest changes in a material's mass. It can also be fitted with a large, 204-position ASC and coupledto gas analysis.

Get Results Faster Without a Baseline Run

A baseline run is usually carried out under test conditions, taking into account heating rate, gas type, and gas flow to guarantee accurate mass change values.

The baseline allows for the subtraction of instrument and buoyancy effects from the sample measurement by accounting for variables like heating rate, crucible type, and geometry.

When using the integrated BeFlat® baseline run for typical temperature measurements, the TG 309 Libra® usually eliminates the need for a separate baseline run. Tests are expedited considerably as a result.

Measuring Principle

Thermogravimetric analysis (TGA) is an exact analytical method that monitors changes in a sample’s mass over time and/or temperature in a defined and regulated environment about crucible type, flow rate, gas atmosphere, heating rate, etc. It is capable of precisely detecting weight variations as small as a microgram. Because of its great sensitivity, even the smallest alterations to a material's chemical and physical characteristics can be detected.

Specifications

Technical Data

Source: NETZSCH-Gerätebau GmbH

. .
Temperature range RT (10 °C) to 1100 °C at the sample
Balance resolution 10 ng
Heating and cooling rates 0.001 K/min to 200 K/min
Cooling time 12 min (1100 °C to 100 °C)
Wide measuring range 2000 mg
Vacuum-tightness << 10-1mbar
Sample crucible volume up to 350 µl
Atmospheres inert, oxidizing, reducing, static, dynamic
Automatic sample changer ASC with 204 positions optionally available

High-End 204-Sample ASC and Removable Sample Trays

The TG 309 Libra® Select and Supreme ASC accommodates two microplate-format sample traysthat can be switched out and hold 96 samples each. When the samples are prepared away from the instrument, this makes it possible to assign them.

An extra fixed strip can hold up to 12 empty crucibles or calibration materials of various sizes and compositions for calibration and correction purposes. Of course, the trays can also be used to define correction measurements using empty crucibles.

[Libra Series for Enhanced Thermogravimetric Analysis]相关推荐
Insulfoam

Insulfoam

Carlisle Construction Materials, a company known for its single-ply roof systems and waterproofin……...

GAMBICA

GAMBICA

GAMBICA is the Trade Association for Instrumentation, Control, Automation and Laboratory Technolo……...

Centaurus Metals

Centaurus Metals

A rich asset base and a clear strategy to deliver value in the short-term Centaurus Metals (ASX: ……...

Beeck GmbH& Co KG

Beeck GmbH& Co KG

Beeckproduces pure mineral lime and silicate based painting systems and natural paints. Beeck off……...

Iron Road Limited

Iron Road Limited

Iron Road has been formed to feed the rapidly expanding DRI and concentrate markets of Asia, Euro……...

今日仪器
  1. Allegheny Surface Technology

    Allegheny Surface Technology

    Allegheny Bradford Corporation is a Pennsylvania corporation with three operating divisions—Allegheny Bradford, Top Line Process Equipment Company, and Allegheny Surface Technology—whic……

    代理品牌 2025-06-15

  2. Thermo Scientific™ MarqMetrix™ All-In-One Process Raman Analyzer

    Thermo Scientific™ MarqMetrix™ All-In-One Process Raman Analyzer

    Video credit: Thermo Fisher Scientific Using the Thermo Scientific™MarqMetrix™All-in-One Process Raman Analyzer, organizations have the ability to perform instantaneous, non-invasive a……

    仪器产品 2025-06-15

  3. Revealing Natural States of Materials with Environmental Scanning Electron Microscopy (ESEM)

    Revealing Natural States of Materials with Environmental Scanning Electron Microscopy (ESEM)

    The Thermo Scientific Quattro ESEM offers comprehensive performance in both imaging and analytics, featuring a distinctive environmental mode (ESEM) that enables the examination of samples in their……

    仪器产品 2025-06-15

返回顶部小火箭