Gentex Corporation
Gentex develops advanced electro-optical products - electronic devices combining photoelectric se……...
The CNSolution™ 9310 Online Cyanide Analyzer is an advanced and versatile analyzer from OI Analytical which determines the content of available cyanide in leaching solutions for precious metals, being designed to operate for this purpose by USEPA Method OIA-1677 and ASTM D 6888-09.
It is based on the use of gas-diffusion amperometry, and this technique prevents interference from the presence of sulfides of copper and other metals which hamper precise measurements by other conventional methods such as titration.
The is extremely useful in gold and silver mining processes as it ensures that cyanide levels are correctly measured at various important points in the cyanidation method of extraction. This in turn helps to control the process and prevents environmental contamination.
The ability of the method to provide constant online measurements allows dynamic monitoring of the whole operation rather than snapshots taken from time to time, by the usual grab sampling methods followed by laboratory analysis. The enhanced accuracy of determination means that cyanide use is controlled better, and this brings down the cost of plant operation.
Features
The 9310 cyanide analyzer gives very precise measurements of available cyanide levels in leaching solutions for precious metal extraction.
It is based upon the time-tested gas-diffusion amperometry principle in USEPA methods OIA-1677 and ASTM D 6888-09.
It can measure cyanide in concentrations which allows its use throughout the process of cyanidation.
Each sample is detected and shown as a real-time peak on the touch-screen display.
It provides constant monitoring and hence increased precision, which in turn allows the cyanide use to be under better control.
Specifications
Operating principle: the CNSolution 9310 online cyanide analyzer operates on FIA by gas diffusion amperometry
Measurement technique: system uses amperometric detection at the silver electrode
Measurement Ranges (ppm): 0.2 to 50 / 2.0 to 500 / 20 to 2000 ppm CN
Reference Methods: USEPA OIA-1677 / ASTM D 6888-09 (Available CN)
Calibration: system has two-point calibration
Measurement accuracy: + 5% at 50-ppm
Sample introduction: sampleis introduced as a continuous online ‘fill-and-spill’ sampling system
Sampling interval: as set by the user
Analysis time: less than three minutes
Operating environment: analyzer operates in environments from 5 – 45 °C, and at up to 90% humidity (non-condensing)
Operator interface: software runs on Windows® CE and has a color touch-screen display
Reagents required: analyzer requires only water, NaOH, HCl, and CN–calibration standards
Power requirements: it runs on a power supply of 24VDC
Output relays: it has two outputs, a system alarm and a sample alarm
Analog output: 2 4-20 mA (the user can configure the concentration)
Data export: user can export the data to a PC via Ethernet, or a USB memory stick
Instrument enclosure: NEMA 4X / IEC Class IP-56
External dimensions: 48.3 cm H x 31.1 cm W x 31.1 cm D(19 &" H x 12.25 &" W x 12.25 &" D)
Weight: 11 kg (24 lbs.)
Gentex develops advanced electro-optical products - electronic devices combining photoelectric se……...
The high-precision coarse/fine XYZ stages are computer-controllable, compact XYZ alignment and po……...
cSince 2001, it belongs to the businesses which deal with nanotechnology in the surface refinemen……...
GEI Inc. is dedicated to the design and manufacturing of LCD, LED, RELAYS, and TRANSFORMERS for N……...
Combined Metals of Chicago LLC, located in Bellwood, IL, is a Stainless Steel Service Center proc……...
Whitehaven Coal is proud to be the leading Australian producer of premium-quality coal. We are th……...
Established in 1991, the Institute of Microelectronics (IME) is a research institute under Singapore’s Agency for Science, Technology and Research (A*STAR). In IME, we focus on delivering hig……
Micropol is based in Stalybridge, Cheshire and has over 30 years experience in polymers. Out technical expertise is world class and out customers world wide. Our extensive in-house facilities allow……
RAS Process Equipment , was established in 1977 and is committed to the design, engineering and manufacturing of quality process equipment for our customers. Equipment can be manufactured to the AS……