IGA-003 MC: Measuring Binary Gas Adsorption Isotherms with the Exclusive IMB Technique

上海仪舶实验室自动化 25-01-23 15:24:13

IGA-003 MC: Measuring Binary Gas Adsorption Isotherms with the Exclusive IMB Technique

The gravimetric sorption analyzer utilizes the IMB method for binary gas sorption analysis.

Benefits of IGA-003-MC

A unique IMB method used to measure binary gas adsorption isotherms

Fully automated operation, including integrated mass flow and MS calibration routines

Only a few grams of sample are required

Precise control of pressure, composition, and temperature conditions

Single component and binary equilibria measured in one experiment

Introducing IGA-003-MC

The IGA-003-MC is a turnkey system that employs the IMB (Integral Mass Balance) analysis method from Hiden Isochema for binary sorption analysis. It comprises an enhanced gas delivery and sampling system, a coupled mass spectrometer, and a gravimetric analyzer.

Key Features

Dedicated sample reactor with combi bath/heater for sample thermostatting

Dynamic mode gas delivery with gas flow calibration

Optimized sampling interface with a close-coupled Hiden mass spectrometer

The recommended sample size is 2-3 grams for operation in the pressure range of 0.5 bar to 10 bar

Unique IMB method for partial uptake determination

The IMB Method

In the IMB method, a mass spectrometer (MS) is used to determine the gas composition at the outlet after a controlled gas mixture passes over a sample suspended from the IGA microbalance.

The partial and total uptake of each gas is then determined as a function of a molar fraction by combining in-situ gravimetric data with outlet gas composition and inlet flow rates. Full time-dependent data is recorded and analyzed to ensure that steady-state conditions are achieved at every step of the measurement.

The IMB technique is a distinctive feature of the IGA-003-MC binary gas sorption analyzer by Hiden Isochema.

Application Data

Inlet and Outlet Mole Fractions

Kinetic data was measured for a binary nitrogen and carbon dioxide adsorption isotherm using the IMB method. The inlet and outlet mole fractions were shown foreach component.

Image Credit: Hiden Isochema

Kinetic Data

Kinetic data was measured for a binary nitrogen and carbon dioxide adsorption isotherm. The total adsorbed mass and the mass of each component was displayed.

Image Credit: Hiden Isochema

Binary Adsorption Isotherms

Binary nitrogen and carbon dioxide adsorption isotherms for Norit RB1 activated carbon were measured using the IMB method.

Image Credit: Hiden Isochema

Multicomponent reactor. Image Credit: Hiden Isochema

[IGA-003 MC: Measuring Binary Gas Adsorption Isotherms with the Exclusive IMB Technique]相关推荐
Smart Vision Lights

Smart Vision Lights

Vision Statement Smart Vision Lights aims to be the preferred value-added LED lighting provider,……...

Evonik VESTAMID

Evonik VESTAMID

The name VESTAMID® stands for an entire range of polyamides with custom tailored properties. ……...

今日仪器
  1. ANGEL BIT from Quarry Mining & Construction Equipment Pty Ltd

    ANGEL BIT from Quarry Mining & Construction Equipment Pty Ltd

    The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……

    仪器产品 2025-04-28

  2. Jetcrete Australia

    Jetcrete Australia

    Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……

    代理品牌 2025-04-28

  3. Borealis AG

    Borealis AG

    For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……

    代理品牌 2025-04-28

返回顶部小火箭