IGA-003 MC: Measuring Binary Gas Adsorption Isotherms with the Exclusive IMB Technique

上海仪舶实验室自动化 25-01-23 15:24:13

IGA-003 MC: Measuring Binary Gas Adsorption Isotherms with the Exclusive IMB Technique

The gravimetric sorption analyzer utilizes the IMB method for binary gas sorption analysis.

Benefits of IGA-003-MC

A unique IMB method used to measure binary gas adsorption isotherms

Fully automated operation, including integrated mass flow and MS calibration routines

Only a few grams of sample are required

Precise control of pressure, composition, and temperature conditions

Single component and binary equilibria measured in one experiment

Introducing IGA-003-MC

The IGA-003-MC is a turnkey system that employs the IMB (Integral Mass Balance) analysis method from Hiden Isochema for binary sorption analysis. It comprises an enhanced gas delivery and sampling system, a coupled mass spectrometer, and a gravimetric analyzer.

Key Features

Dedicated sample reactor with combi bath/heater for sample thermostatting

Dynamic mode gas delivery with gas flow calibration

Optimized sampling interface with a close-coupled Hiden mass spectrometer

The recommended sample size is 2-3 grams for operation in the pressure range of 0.5 bar to 10 bar

Unique IMB method for partial uptake determination

The IMB Method

In the IMB method, a mass spectrometer (MS) is used to determine the gas composition at the outlet after a controlled gas mixture passes over a sample suspended from the IGA microbalance.

The partial and total uptake of each gas is then determined as a function of a molar fraction by combining in-situ gravimetric data with outlet gas composition and inlet flow rates. Full time-dependent data is recorded and analyzed to ensure that steady-state conditions are achieved at every step of the measurement.

The IMB technique is a distinctive feature of the IGA-003-MC binary gas sorption analyzer by Hiden Isochema.

Application Data

Inlet and Outlet Mole Fractions

Kinetic data was measured for a binary nitrogen and carbon dioxide adsorption isotherm using the IMB method. The inlet and outlet mole fractions were shown foreach component.

Image Credit: Hiden Isochema

Kinetic Data

Kinetic data was measured for a binary nitrogen and carbon dioxide adsorption isotherm. The total adsorbed mass and the mass of each component was displayed.

Image Credit: Hiden Isochema

Binary Adsorption Isotherms

Binary nitrogen and carbon dioxide adsorption isotherms for Norit RB1 activated carbon were measured using the IMB method.

Image Credit: Hiden Isochema

Multicomponent reactor. Image Credit: Hiden Isochema

[IGA-003 MC: Measuring Binary Gas Adsorption Isotherms with the Exclusive IMB Technique]相关推荐
American Roller Company

American Roller Company

As a leading manufacturer of industrial rollers, American Roller Company offers rubber, urethane,……...

美国KACTUS

KACTUS是一家服务于全球生物制药和诊断客户的生物技术公司。我们专注于商业化蛋白质生产,以满足药物开发……...

Advanced Optics Inc.

Advanced Optics Inc.

Advanced Optics, Inc. has been manufacturing high quality optical components for almost 40 years.……...

[db:国别翻译]英国Swanstone

[db:国别翻译]英国Swanstone

Swanstone Ltd 是众多知名欧洲制造商值得信赖的合作伙伴和长期代理。我们在欧洲各地提供优质生产设备、……...

今日仪器
  1. Item North America

    Item North America

    Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……

    代理品牌 2025-09-04

  2. Streaming Answers: SurPASS™ 3

    Streaming Answers: SurPASS™ 3

    SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……

    仪器产品 2025-09-04

  3. AHP Materials

    AHP Materials

    AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……

    代理品牌 2025-09-04

返回顶部小火箭