The Model 383 Piezoelectric Accelerometer from Columbia Research Laboratories has been specifically developed to quantify vibration phenomena and high amplitude shock precisely. The high resonant frequency of 80 kHz leads to the least output distortion as a result of ringing while quantifying impact transients with durations as low as 50 µs.
Model 383 involves a sophisticated seismic system in which the sensing crystal is nearly constrained completely and free from zero shift after high energy effects. This accelerometer has not been affected by impact transverse components and has the ability to measure up to its rated value of 20,000 gand even to 50,000 gwith a steady operation.
Its robust construction guarantees high-performance, long life, repeatability and stability. Internal electrical isolation reduces ground loop issues caused due to noise currents.

Image Credit: Columbia Research Laboratories
High Shock to 20,000 G
Low base strain sensitivity
Isolated electrically
Availability of high resonant frequency
Sensitivity provided up to 0.5 pC/g
Specifications
Source: Columbia Research Laboratories
| Transfer / Electrical | 383 |
|---|---|
| Charge Sensitivity1 | 0.5 pC/g Nominal0.95 pC/g Maximum |
| Capacitance | 325 +/-100 pF |
| Frequency Linearity2 | +/-5% Max2 Hz To 15,000 Hz |
| Mounted Resonant Frequency | 80 KHz, Min. |
| Transverse Sensitivity | 5% Max |
| Amplitude Linearity | +/-1.0% (BFSL) |
| Insulation Resistance | 10,000 M Ohm Min, 50 VDC Test |
| Isolation Resistance | 100M Ohm, Min. |
| Environmental | 383 |
|---|---|
| Vibration Limit | 1,000 g Max (Sine) |
| Shock Limit | 20,000 g Max |
| Temperature Range | -65 To +350 Deg F (-54 To +175 Deg C) |
| Humidity 3 | 0 To 95% R.H. |
| Base Strain Sensitivity | 0.003 g/uE Equiv, Typical |
| Electromagnetic Sensitivity | 0.005 g (Equiv / 100 Gauss) |
| Acoustic Sensitivity | 0.005 g RMS (Equiv @ 150 dB SPL) |
| Physical | 383 |
|---|---|
| Configuration | Ring Shear |
| Size | 0.500 In. Hex x 0.550 In. H (12.7 mm Hex x 19.05 mm H) |
| Weight | 0.28 Oz (8 Gm) |
| Case Material | 18-8 Stainless Steel |
| Electrical Interface Coaxial | 10-32 Thread |
| Mounting | 10-32 Tapped Base |
Notes:
1 At +75 Deg F, 10 g Peak, 100 Hz; Lower Frequency Limit is Determined by Associated Electronics2 Referenced to Sensitivity @ 100 Hz.3 Unit is Epoxy Sealed
Accessories Supplied
(1) 10-32 x 0.375” L Mounting Stud, St Stl
(1) Hardwood Storage Case
(1) Standard Calibration Data
(1) Certificate of Calibration Traceable to N.I.S.T.
DME 公司是其全球服务客户的重要资源,提供业内最广泛的市场领先产品。七十余年的模具技术领导地位,使……...
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ Victorian Ceramicsbrings together over 50 years of experience i……...
We are focused on the impact and the relentless pursuit of change, for good. The University of Pi……...
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ 卡尔·齐斯(Carl Zeiss)的显微镜业务组是世界上唯一的光,X射线,……...
Suntton Co., Ltd. is a manufacturer of plant growth regulators and chemical intermediates. The co……...
The TacticID®-N Plus is a portable Raman Spectrometer optimized for non-contact forensic anal……...
Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……
SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……
AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……