Northwell Health
Northwell Health is New York State’s largest health care provider and private employer, wit……...
Features
Connects a computer to sensors and controls using analog and digital inputs and digital outputs using Windows® software
Connects directly to sensors: thermocouple, voltage, thermistor, load cell, RTD, strain gauge, potentiometer, current, resistance
Supplied with software for real-time display, storage and post-acquisition analysis of measured data. Compatible with Windows® ≥ XP SP3, 32-bit or 64-bit
iNET-601 provides ±36 V bank electrical isolation
16SE/8DI Voltage input channels with extremely accurate 24-Bit A/D converter supporting ±20 mV to ±10V ranges 4 Digital I/O (4 mA sink/source, 0 to 3.3 V)
iNET-600 connects I/O signal ground to computer ground; powered using USB bus
Description
The iNET-600 Series A/D module provides 16SE/8DI voltage input channels (Ch#1...#16). Each of these channels can be independently programmed using Windows software which supports direct connection to many common sensor types. The voltage input range on each channel can be independently programmed using the software to one of the following: ±20 mV, ±40 mV, ±80 mV, ±150 mV, ±300 mV, ±600 mV, ±1.2 V, ±2.5 V, ±5 V, ±10 V.
A mating Hd44 female connector and cover are included. Alternatively, an iNET-600 series can be attached to the following optional wiring boxes: iNET-500, iNET-511, iNET-512. An iNET-510 wiring box should be used if work with thermocouples is required, as it provides internal cold junction compensation.
The iNET-600 Series is a stand-alone USB data acquisition system. No additional components, for example, an external power supply, are required. Included in the box are an iNET-600 Series hardware device, a USB Cable, a CD containing relevant software, a mating Hd44 female connector and a Hd44 Cover.
The maximum digitizing sample rate is 160 K sample/second for 1 channel, 12 K samples/sec/channel for 2 channels, 6 K samples/sec/channel for 4 channels, and 3 samples/sec/channel for 8 channels. For more details, see voltage accuracy.
For each channel, a range of parameters are programmable using the software. These parameters are the following: A/D signal-averaging-per-point (0 ... 100 mSec), sample rate (samples-per-second-per-channel), voltage measurement range (±20 mV to ±10 V), Digital IIR filter (low pass, band pass, high pass, or band stop), sensor type, and single-ended or differential wiring.
Excitation power is provided for sensors (+3.3 V ±0.2 V, < 80 mA, 28 mA per sensor max), as are other end user power voltages. Referenced to instruNet ground, this 3.3 V, is automatically read back by A/D during the calculation of sensor values.
The digital I/O port for the 4 mA sink/source is made up of 4 individual TTL compatible lines (Ch#25...#28), which can each be configured as either input or output bit. When configured as an input, a channel can be used to sense a digital low (0 V to 0.8 V) or a digital high (2 to 5.5 V). When configured as an output, a channel can be set low (e.g. < 0.8 V) or high (e.g. > 2 V). These I/O pins are short-circuit protected against high voltages greater than 6.0 V and down to -6.0 V.
Easily Set Up Sensors
The sensors can be set up easily using the Quick Setup dialog box.
Optional Wiring Boxes
Each of the iNET-510, iNET-511 andiNET-512 wiring boxes can be easily bolted to devices in the iNET-600 series. The iNET-510 is the cheapest and the simplest, and also offers thermocouple support. The iNET-511 includes 8 BNC connectors, while the iNET-512 includes a vRef/2 source. This source can be used to help complete ¼ bridge and ½ bridge strain gauge circuits. If thermocouple measurement is required, then the iNET-510 is the only wiring box that will work, as a result of its internal temperature sensor for cold junction compensation.
Model No. | BNC connectors | Thermocouple support | 1/4 and 1/2 bridge strain gage vRef/2 support | Individual banks of screw terminals for each sensor |
---|---|---|---|---|
iNET-510 | 0 | yes | no | no |
iNET-511 | 8 | no | no | yes |
iNET-512 | 0 | no | yes | yes |
Specifications
Analog Inputs
Number of Channels: 16 single-ended (SE)/8 differential (DI)
A/D Converter: 24-bit when averaging each point for >1m sec; and 16 bits when not averaging
Voltage: See voltage accuracy/range charts
Voltage Ranges: ±20 mV, ±40 mV, ±80 mV, ±150 mV, ±300 mV, ±600 mV, ±1.2 V, ±2.5 V, ±5 V, ±10 V
Electrical Isolation (iNET-601 Only): ±36 Vdc bank isolation
Protected Voltage: ±30 Vdc with power on or off
RFI Filter: 13 KHz RFI filter on <±150 mV range
Digital Filter: Low Pass, High Pass, Band Pass, or Band Stop
Digital Filter Type: Elliptic, Chebyshev B, Chebyshev S, or Butterworth
Common Mode Voltage: ±10 Vdc
Common Mode Rejection Ratio: >110 dB (0 to 60 Hz)
Input Impedance: 100 MΩ
Sensor Measurement
Thermocouple: J, K, T, E, R, S, B, N, C, G, D
Thermistor: 2252 Ω (OMEGA 44000 Series), custom
RTD: 100 Ω, 500 Ω, 1 kΩ platinum
Load Cell: 10 kg, 25 kg, 100 kg, 250 kg, 1000 kg, 5000 kg, custom
Strain: 120 Ω or 350 Ω. 1⁄4 bridge, half bridge or full bridge; internal i60x voltage reference supports a maximum of three 120 Ω bridges; and eight 350 Ω bridges
Potentiometer: 1 to 50 kΩ
Current: ±80 uA, ±120 uA, ±500 uA, ±600 uA, ±800 uA, ±1.2 mA, ±2.5 mA, ±12 mA, ±24 mA, 0 to 24 mA, custom
Resistance: 0 to 33 Ω, 0 to 100 Ω, 0 to 330 Ω, 0 to 1 kΩ, 0 to 3300 Ω, 0 to 10 kΩ, custom
LVDT/Flow/Pressure: Current, voltage, mV/V
Digital I/O
Number of Channels: 4 digital I/O (4 mA sink/source, 0 to 3.3V)
“0” Input Voltage: 0 to 0.8 Vdc
“1” Input Voltage: 2 to 5.5 Vdc
“1” Input Current: Amps = Vin / 50 kΩ (“1” must drive internal 50 kΩ pulldown resistor)
“0” Output Voltage: <0.7 Vdc at <2 mA; < 0.9 Vdc at 4 mA
“1” Output Voltage: 2.2 to 3.3 Vdc at 4 mA
Pull-Down Resistor: 50 kΩ ±1%
Environmental
Operating Environment: 1 to 70 °C (34 to 158 °F), <90% RH, no condensation
Storage Temperature: -20 to 70 °C (-4 to 158 °F)
Power
Power Consumed From USB Cable: +5 Vdc 255 mA typical (433 mA max)
Voltage Reference At Hd44 Connector: 3.30 Vdc (80 mA)
Unregulated Power Available to User At Hd44 Connector: 5 Vdc (8 mA), ±15 Vdc (4 mA)
Mechanical
Material: Plastic enclosure
Dimensions: 58 x 96 x 24 mm (H x W x D)
Weight: 454 g
Mounting: Place on desktop, attach to wall, or place inside another enclosure (OEM)
Easily Set Up Sensors
iNET-510 wiring box with screw terminals
iNET-511 wiring box with BNC connectors
iNET-512 Strain gage/sensor wiring box with screw terminals
Northwell Health is New York State’s largest health care provider and private employer, wit……...
RAS Process Equipment , was established in 1977 and is committed to the design, engineering and m……...
Delivering individual, specific ultra high-speed solutions that meet our clients needs exactly...……...
Tempo developed a thin wall molding technique known as “DRY molding” beginning in Aug……...
PPK Mining Equipment is a company committed to growing and investing in innovative technology acr……...
Gotec SA manufactures small electromagnetic pumps. We provide Conception, solution, realisation o……...
The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……
Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……
For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……