[db:国别翻译]德国核心系统Ag
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ 先进的清洁生产GmbH开发了CO2雪地喷火系统,具有高客户利益,可在不……...

Precise measurements of heat build-up or blowout processes and the identification of the thermal set can be carried out by the HBU 523 Gabometer system. It is a development made depending on the fixed Goodrich Flexometer.
Both force- and elongation-controlled tests can be performed with this advanced flexometer. The HBU 523 Gabometer is ideal for enhancing the thermal durability and dissipation of the semi-finished tire components, absorbers, or dampers.
The new generation flexometer helps measurethe material stiffness (E modulus, tanδ option) and damping.
UserAdvantages
Heat build-up and blowout tests as per Goodrich (DIN 53533, ASTM D 623, ISO 4666/3, ISO 4666/4, BS 903 part A50, and JIS K 6265)
Goodrich flexometer tests are performed
Static: comes with strain- or stress-controlled mode
Dynamic: strain- or stress-controlled mode available
Wide temperature range (option)
Wide frequency range (option)
Concurrent measurement of the visco-elastic properties (option)
Automatic Sample Changer (ASC) for fully automatic testing (24 hours) (option)
Visco-elastic properties in DMTS/DMA mode (option)
Pulse load mode available (option)
Hysteresis analysis (option)

Image Credit: NETZSCH-Gerätebau GmbH
Technical Data
Dynamic Strain Range: up to ± 15 mm
Static Deformation: comes up to 70 mm
Frequency Range: 30 Hz
0.0001 Hz to 100 Hz (optional)
Temperature Range: −160 °C up to 300 °C
Test Specimen Size: Diameter: up to 30 mm (optional <40 mm), depending on model
Length: 25 mm

Image Credit: NETZSCH-Gerätebau GmbH
Accessories
Sample Holder
Pair of insulated compression sample holders targeted for flexometer tests fitted with a contact thermocouple is available for recording the sample temperature on the surface of the test specimen during heat build-up tests.
Recording of the sample “center” temperature inside the core of the test specimen during heat build-up tests together with a needle-type manual mode (Option) thermocouple (horizontal operation).
Automatic recording of the sample “center” temperature within the core of the test specimen following heat build-up tests having a needle-type thermocouple (vertical operation) driven by a pneumatic penetration system automatic mode (Option).

Sample arrangement with vertical needle thermocouple (optional). Image Credit: NETZSCH-Gerätebau GmbH
Automatic Sample Changer
Compression magazine goes for up to 50 compression testing specimens. A robot grip system available takes the samples from the magazine and feeds the HBU 523 Gabometer.

Image Credit: NETZSCH-Gerätebau GmbH
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ 先进的清洁生产GmbH开发了CO2雪地喷火系统,具有高客户利益,可在不……...
We offer a range of services as well as supply of product. We have vast experience in the jointin……...
NanoSteel 是纳米结构钢材料设计领域的全球领导者。十二年来,公司不断创新,创造了一代又一代的铁基合……...
Imatek is a leading UK based manufacturer of materials testing equipment primarily in the field o……...
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ OEM的和最终用户都定期指定海顿涂料是捍卫其设备免受磨损和腐蚀危害……...
The McPherson Inc Model 248/310G Grazing Incidence Monochromator is suited to Soft X-ray and Extr……...
Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……
SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……
AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……