Gas Analysis with the Mass Flowmeter

上海仪舶实验室自动化 25-01-23 16:12:49

Gas Analysis with the Mass Flowmeter

The FMA-4100/4300 series mass flow totalizers and meters can be programmed remotely using the RS232 or RS485, functioning to measure the rate of gas flow and record it in 23 selectable units. These devices have a multitude of applications due to an extensive list of functions, including high and low gas flow alarms, gas flow totalizers, automatic zero adjustments, 2s relay outputs, jumper selectable 0 to 5 Vdc or 4 to 20 mA analogous outputs, status LED diagnostics, storable calibrations and internal or user-specific K-factors. The local LCD display has 2 lines, each of 16 characters and modifiable back lighting, which enables concurrent readings. Use of RS232 or RS485 enables access of further data, such as the temperature of CPU, auto zero, flow, linearization table adjustment, settings for both totalizer and alarms, gas table, conversion factors, selection of units and dynamic response compensation.

Both the local and remote activation of the FMA-4100 or 4300 enables automatic offset zero adjustment. This is particularly useful in situations where there is minimal flow through the meter when it is being modified. Digital commands enable the current automatic zero value to be read, saved or started. Totalizer settings can be altered in order to enable various functions: assigning action to a pre-set value, setting to zero, starting at a pre-set flow, starting/stopping totalizing and reading. Alarms can also be set up prior to use which can indicate both high and low flow, and can be appointed pre-set delay intervals of 0 to 3600 seconds, which activate the contact closer. An additional feature, called the latch mode control, functions to permits each relay to be latched on or ensure the interrelated alarm status. However, these transducers cannot be used to measure oxygen.

Specifications

Calibrations: Performed at standard conditions [101.4 kPa (14.7 psia) and 21.1 °C (70 °F)] unless otherwise requested or stated

Environmental (PER IEC 664): Installation Level II; Pollution Degree II

Flow Accuracy (Including Linearity): ±1% of FS at calibration temperature and pressure

Repeatability: ±0.15% of full scale

Flow Temperature Coefficient: 0.15% of full scale/°C or better

Flow Pressure Coefficient: 0.01% of full scale/psi (6.895 kPa) or better

Turndown Ratio: 50:1

Flow Response Time: 600 ms time constant; approximately 2 seconds to within ±2% of set flow rate for 25 to 100% of full scale flow

Max Gas Pressure: 3447 kPa gauge (500 psig)

Max Pressure Drop: Max Flow ≤ 10 SLM: 1.28 kPa (0.18 psi) Max Flow > 10 SLM: 27.58 kPa (4 psi)

Gas and Ambient Temperature: 5 to 50 °C (41 to 122 °F)

Relative Gas Humidity: Up to 70%

Leak Integrity: 1 x 10-9 SCCS He max to the outside environment

Attitude Sensitivity: Deviation of up to 1% from stated accuracy, after re-zeroing

Output Signals: Linear 0 to 5 Vdc (3000 Ω min load impedance); Linear 4 to 20 mA (500 Ω max loop resistance). Max noise 20 mV peak to peak (for 0 to 5 Vdc output)

Relay: SPDT (30 Vdc, 1A)

Transducer Input Power: 11 to 26 Vdc, 100 mV max peak to peak output noise

Power Consumption: +12 Vdc (200 mA max); +24 Vdc (100 mA max); Circuit board has built-in polarity reversal protection, 300 mA resettable fuse provide power input protection

Wetted Materials:

Standard Aluminum Models: Anodized aluminum, brass, 316 stainless steel, FKM O-rings

Optional Stainless Steel Models: 316 stainless steel, FKM O-rings

Optional O-ring Materials: Buna, EPR (Ethylene Propylene), or perfluoroelastomer

Inlet and Outlet Connections:

Model FMA-4100/4300: Standard 6.35 mm (1/4") compression fittings for up to 50 SLM. Standard 9.53 mm (3/8") for models above 60 SLM

Optional: 3.18 or 9.53 mm (1/8" or 3/8") compression fittings

Display (FMA-4300 Models): Local 2 lines x 16 characters LCD with adjustable backlight (2-lines of text)

Calibration Options: Standard is one 10-point NIST traceable calibration. Optional, up to 9 additional calibrations may be ordered at additional charge. Contact OMEGA for additional information

CE Compliance: EMC compliance with 89/336/EEC as amended

Emission Standard: EN 55011:1991, Group 1

Class A Immunity Standard:

EN 55082-1:1992

[Gas Analysis with the Mass Flowmeter]相关推荐
Jabil

Jabil

Founded in 1966 and headquartered in St. Petersburg, Florida, Jabil is a manufacturing solutions ……...

Bisichi Mining PLC

Bisichi Mining PLC

Bisichi Mining PLC is based in London, the United Kingdom. Bisichi Mining engages in mining and p……...

今日仪器
  1. Item North America

    Item North America

    Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……

    代理品牌 2025-09-04

  2. Streaming Answers: SurPASS™ 3

    Streaming Answers: SurPASS™ 3

    SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……

    仪器产品 2025-09-04

  3. AHP Materials

    AHP Materials

    AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……

    代理品牌 2025-09-04

返回顶部小火箭