Floor Standing Capillary Rheometer - Rosand RH7, RH10, and Rosand RH2000

上海仪舶实验室自动化 25-01-23 16:03:34

Floor Standing Capillary Rheometer - Rosand RH7, RH10, and Rosand RH2000

The sturdy“H” frame design of the Rosand RH7 and RH10 floor standing capillary rheometers, which are in use in hundreds of research labs worldwide, permits operation under extremely high loading conditions and offers optimal space for a variety of accessory configurations.

Floor Standing Capillary Rheometer - Rosand RH7, RH10, and Rosand RH2000

Image Credit: NETZSCH- Gerätebau GmbH

Features and Benefits

Research-level Rosand RH7 and RH10 capillary rheometers provide extremely varied measuring capabilities for materials subjected to high shear rate extrusion and high pressure, ranging from foodstuffs to coatings and inks, and polymer melts to ceramics.

Below the barrel exit, the design accepts optional accessories like melt cutters, die swell measurements, slot die systems, and melt strength (Haul Off)

Extensive dynamic speed range (up to 400,000:1) and high force range (up to 100 kN) enable test correlation with actual material processing conditions.

As a standard, twin-bore barrels allow the simultaneous calculation of extensional (elongational) viscosity and absolute shear viscosity measurements.

Various optional barrel materials and sizes are available to measure aqueous, chemically aggressive, or heat-sensitive samples.

Many highly accurate tungsten carbide dies are available as standard (Hastelloy is optional) to accommodate various test types and materials.

Configured with low noise, triple-stage amplifiers for optimal measurement sensitivity at the die entry when using “zero-length” dies (extensional viscosity measurements), easily interchangeable melt-pressure transducers are available to meet all test requirements

When testing in a dry, inert atmosphere, a nitrogen purge option reduces sample degradation.

An integrated fume chamber with extraction releases sample gases for operator safety.

Flowmaster software is user-friendly and offers comprehensive tests and analyses for shear and extensional viscosity. It can also be used to determine wall slip, pVT, melt strength, and melt fracture, in addition to sample stability.

Proprietary bi-modal speed control algorithms that can be used at high and low speeds

The sample temperature can be precisely controlled using three separate zone heaters and highly accurate platinum resistance thermometers. Options for cooling coils and high temperatures (up to 500 ºC) are also available.

Rigid ‘H’ frame design for compliance-free measurements in transient tests such as pVT determination

Key Applications

Simulation of processes dominated by extensional viscosity, such as film-blowing thermoforming, blow molding, and fiber-spinning

Rheological characterization of a solution or polymer across a wider range of temperatures and shear rates

Evaluating a material’s behavior at shear rates that are important to the process, such as those in high-speed coating and printing applications

Assessing the behavior of extrusion for procedures like hot melt extrusion and injection molding

Measurement of elasticity and associated characteristics of materials, such as die swell.

Detecting polymer instabilities such as thermal degradation and melt fracture

Industry Applications

Polymers

Coatings

Ceramics

Metals

Pharmaceuticals

Sealants

Foods

Inks

Large Floor Standing Capillary Rheometer - Rosand RH2000

Floor Standing Capillary Rheometer - Rosand RH7, RH10, and Rosand RH2000

Image Credit: NETZSCH- Gerätebau GmbH

The Rosand RH2000 capillary rheometer from NETZSCH is a small device that meets most capillary rheometry test needs. The rheometer combines numerous complex capabilities common to larger floor-standing versions and can be configured for research measurements and quality control purposes.

Features and Benefits

The Rosand RH2000 benchtop capillary rheometer offers incredibly versatile measurement capabilities and configuration options from polymer melts to pharmaceutical processing and from foodstuffs to inks and coatings.

Maximum speed (up to 1200 mm/min) and maximum driving force (up to 20 kN) capabilities enable a wide range of shear rates and correlation with various real-world material processing circumstances.

Single- and twin-bore barrel versions are available for low-cost regular measurement capabilities, as well as dual measurements for simultaneous assessment of absolute extensional (elongational) and shear viscosity.

The unique swivel head design makes the rheometer barrel conveniently accessible for instrument maintenance and sample loading.

The rigid single-piece cantilever frame design provides extremely high mechanical strength and rigidity for a compact benchtop item.

The special swivel head design allows easy access to the rheometer barrel for sample loading and instrument maintenance.

A range of different barrel materials and sizes are offered to facilitate the measurement of samples that are aqueous, chemically aggressive, or heat sensitive.

The sample temperature can be adjusted using three independent zone heaters and extremely accurate platinum resistance thermometers. Further options exist for high temperatures (up to 500 °C) and cooling coils.

Triple-stage amplifiers in melt pressure transducers' design minimize noise and allow for easy replacement, maximizing measurement sensitivity at the die entrance.

Proprietary bi-modal speed control algorithms can be applied at both high and low speeds.

To reduce sample deterioration, there is a purge nitrogen option

Attachments for measuring die swell to assess elastic samples

Flowmaster software is easy to use and provides a wide range of shear and extensional viscosity tests and analyses. It also allows for the determination of melt fracture, wall slip, and sample stability

Key Applications

The simulation of processes that are dominated by extensional viscosity, such as blow molding, film blowing, thermoforming, and fiber spinning

Recognizing instabilities in polymers, such as melt fracture and thermal deterioration

Assessing the behavior of extrusion in techniques such as injection molding and hot melt extrusion

Characterizing the rheology of suspension or polymer over a broad range of temperatures and shear rates

[Floor Standing Capillary Rheometer - Rosand RH7, RH10, and Rosand RH2000]相关推荐
FiberTech Optica

FiberTech Optica

FiberTech Optica is all about solutions. We solve your problems, even the tough ones. We do it qu……...

ERCO Worldwide

ERCO Worldwide

ERCO Worldwide is a division of Superior Plus LP, a wholly owned subsidiary of Superior Plus Corp……...

ReVerie Limited

ReVerie Limited

Reverie are a highly experienced composite manufacturing company that is able to manufacture besp……...

VISTA Training, Inc.

VISTA Training, Inc.

VISTA Training, Inc., founded in 1991, provides training solutions for people involved in earth m……...

Tremco CPG Inc.

Tremco CPG Inc.

Tremco Global Sealants Division is the world’s foremost supplier of sealant, weatherproofin……...

今日仪器
  1. ANGEL BIT from Quarry Mining & Construction Equipment Pty Ltd

    ANGEL BIT from Quarry Mining & Construction Equipment Pty Ltd

    The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……

    仪器产品 2025-04-28

  2. Jetcrete Australia

    Jetcrete Australia

    Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……

    代理品牌 2025-04-28

  3. Borealis AG

    Borealis AG

    For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……

    代理品牌 2025-04-28

返回顶部小火箭