Flash Diffusivity Systems - DLF-1200 Laser Flash Analysis

上海仪舶实验室自动化 25-01-24 17:03:44

Flash Diffusivity Systems - DLF-1200 Laser Flash Analysis

All the advanced tools provided by TA Instruments are designed for measuring thermal diffusivity up to 1200°C using the Flash method.

This method enables measuring definite heat capacity and thermal conductivity of materials with various thermal properties. All tools are equipped with multi-specimen testing capability, thereby enhancing productivity and specific heat capacity measurements. The tools are capable of full time pulse mapping, precision optics, and current data analysis.

The Discovery Flash data analysis software uses several current methods for heat loss corrections. For instance, the Clark and Taylor method is used as a highly precise basic purpose procedure for regulating thermal diffusivity based on the radiation heat losses, finite pulse width, and non-isothermal local sample conditions. There are more than 20 different analysis models and correction programs built into the software, thus providing maximum precision for all types of materials.

Some of the available models include:

Heckman

Moment

Degiovanni

Parker

Cowan

Koski

Least Squares

Logarithmic

The tool detector is designed for matching the operating temperature range of the Environmental Module. In the case of moderate–to-high-temperature measurements, an indium antimonide (InSb) IR detector is used. The IR detector can be cooled with liquid nitrogen so as to ensure stable output and highest repeatability.

Key Features

The main features of TA Instruments’ flash diffusivity systems are as follows:

Flash method is widely accepted and documented in ASTM E2585, ASTM E1461, DIN 30905, DIN EN821, ISO 22007-4:2008 and ISO 18755:2005

Unmatched precision of pulse-shape and pulse-width correction calculations coupled with highly accurate determination of the t0

High sensitivity, quick response sensors

Precise measurement of transient temperature changes

Factory-aligned detector does not involve user exchange or alignment

[Flash Diffusivity Systems - DLF-1200 Laser Flash Analysis]相关推荐
VaCom Technologies

VaCom Technologies

VaCom provides refrigeration and energy efficiency expertise to utilities and directly to commerc……...

RC1mx from METTLER TOLEDO

RC1mx from METTLER TOLEDO

Chemical process safety by design. The RC1mx calorimeter with HFCal option available from METTLER……...

Zivid Labs

Zivid Labs

Zivid Labs was founded in 2015 by Henrik and Øystein, two former SINTEF senior researchers. ……...

SpinDrive

SpinDrive

SpinDrive mitigates CO2 emissions by improving the energy efficiency of the industrial processes ……...

今日仪器
  1. Institute of Microelectronics

    Institute of Microelectronics

    Established in 1991, the Institute of Microelectronics (IME) is a research institute under Singapore’s Agency for Science, Technology and Research (A*STAR). In IME, we focus on delivering hig……

    代理品牌 2025-07-30

  2. Micropol Limited

    Micropol Limited

    Micropol is based in Stalybridge, Cheshire and has over 30 years experience in polymers. Out technical expertise is world class and out customers world wide. Our extensive in-house facilities allow……

    代理品牌 2025-07-30

  3. RAS Process Equipment

    RAS Process Equipment

    RAS Process Equipment , was established in 1977 and is committed to the design, engineering and manufacturing of quality process equipment for our customers. Equipment can be manufactured to the AS……

    代理品牌 2025-07-30

返回顶部小火箭