[db:国别翻译]英国吉拉德公司有限公司,彼得
欢迎访问2007年吉拉德网站。这里提供塑料和橡胶挤出旋转切割机、锯机、牵引机、牵引机、输送机和卷取机……...

QUANTAX EDS for TEM includes the XFlash®7T,the latest generation of EDS detectors from Bruker Nano Analytics.
80 keV upper energy limit - Identify and quantify all elements present
1 Å stable resolution with drift correction for the mapping of periodic structures, such as atoms and layers, at the nanoscale
3 powerful TEM quantification methods to suit different applications – theoretical and experimental Cliff-Lorimer factors as well as Zeta-factor interpolation
QUANTAX EDS for TEM systems collect spectra at the maximum collection and take-off angle for fast and highly sensitive data acquisition, allowing users to achieve maximum throughput. As the system avoids any mechanical and electromagnetic interference, tilting of the specimen, and minimizes shadowing and system peaks, the collected data is clean and requires little or no post-acquisition corrections. In addition, an enhanced drift correction feature allows for high-resolution nanoscale measurements to be taken quickly using a fast and stable detector stage.
The XFlash®7T has a slim-line design and geometrical optimization for each flange type and microscope pole piece, helping provide users with the best configuration for their measurements.
Bruker’s established background in the field of EDS with tried-and-tested quantification methods helps ensure unambiguous results with either the automated collection of data for batch processing or collection using API options for specific measurements. Time-resolved data collection is also possible for in-situ experiments with data that changes over time, such as temperature ramping experiments.
The experts in Bruker Nano Analytics’s EDS team will help ensure that the detector and microscope (TEM, STEM or T-SEM) configuration is tailored for each user’s application. Training can also be provided to ensure that users can run their system at its full potential.
Download the Brochure
ESPRIT Software
QUANTAX EDS for TEM uses ESPRIT software for the collection, processing and interpretation of data.
Quantification step options which include default recommendations for simple use, individual setup, in-depth adjustment, and saving/reloading of methods.
Three different quantification methods to cover all possibilities:Theoretical and experimental Cliff-Lorimer factors,Zeta-factors, and the estimation of Zeta-factors.
TEM-specific high-energy element lines exceeding 40 keV included to ensure definite conclusions.
Choose between three EDS background models, including a mathematical model, a physical model for thick lamellae, and a physical model for bulk materials.
Cliff-Lorimer measurement including pre-set absorption correction.
欢迎访问2007年吉拉德网站。这里提供塑料和橡胶挤出旋转切割机、锯机、牵引机、牵引机、输送机和卷取机……...
The JSM-IT800 Ultrahigh Resolution Field Emission SEM from JEOL is a groundbreaking FE-SEM equipp……...
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ Cimbria在世界范围内设计和交付了数千多种植物。 More than 50 yea……...
欢迎来到阿美特克科学仪器公司——我们引领着高精度电化学、电池、储能、腐蚀和材料分析仪器的创新设计、……...
Over 30 years of innovation Incorporated in 1972, Chiu Technical has been a private label manufac……...
Building upon the industry-leading Helios DualBeam family’s high-performance imaging and an……...
Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……
SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……
AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……