Ernest Bennett (Sheffield) Ltd
Ernest Bennett (Sheffield) Ltd was formed in 1956 to service and maintain all types of Industrial……...

QUANTAX EDS for TEM includes the XFlash®7T,the latest generation of EDS detectors from Bruker Nano Analytics.
80 keV upper energy limit - Identify and quantify all elements present
1 Å stable resolution with drift correction for the mapping of periodic structures, such as atoms and layers, at the nanoscale
3 powerful TEM quantification methods to suit different applications – theoretical and experimental Cliff-Lorimer factors as well as Zeta-factor interpolation
QUANTAX EDS for TEM systems collect spectra at the maximum collection and take-off angle for fast and highly sensitive data acquisition, allowing users to achieve maximum throughput. As the system avoids any mechanical and electromagnetic interference, tilting of the specimen, and minimizes shadowing and system peaks, the collected data is clean and requires little or no post-acquisition corrections. In addition, an enhanced drift correction feature allows for high-resolution nanoscale measurements to be taken quickly using a fast and stable detector stage.
The XFlash®7T has a slim-line design and geometrical optimization for each flange type and microscope pole piece, helping provide users with the best configuration for their measurements.
Bruker’s established background in the field of EDS with tried-and-tested quantification methods helps ensure unambiguous results with either the automated collection of data for batch processing or collection using API options for specific measurements. Time-resolved data collection is also possible for in-situ experiments with data that changes over time, such as temperature ramping experiments.
The experts in Bruker Nano Analytics’s EDS team will help ensure that the detector and microscope (TEM, STEM or T-SEM) configuration is tailored for each user’s application. Training can also be provided to ensure that users can run their system at its full potential.
Download the Brochure
ESPRIT Software
QUANTAX EDS for TEM uses ESPRIT software for the collection, processing and interpretation of data.
Quantification step options which include default recommendations for simple use, individual setup, in-depth adjustment, and saving/reloading of methods.
Three different quantification methods to cover all possibilities:Theoretical and experimental Cliff-Lorimer factors,Zeta-factors, and the estimation of Zeta-factors.
TEM-specific high-energy element lines exceeding 40 keV included to ensure definite conclusions.
Choose between three EDS background models, including a mathematical model, a physical model for thick lamellae, and a physical model for bulk materials.
Cliff-Lorimer measurement including pre-set absorption correction.
Ernest Bennett (Sheffield) Ltd was formed in 1956 to service and maintain all types of Industrial……...
"Best Service with Good Quality at Zero Defeat"is the philosophy we always aimed at, wi……...
Straub Metal 是一家 T439 和 T409 不锈钢经销商及金属服务中心,供应 439 和 409 不锈钢合金板材、衬……...
SECO/WARWICK is a leading global manufacturer of heat processing end to end solutions. Expertise……...
Hascall Steel Company is a full service flat rolled steel service center, providing slitting, she……...
The VeraSpec HRQ is a high resolution quadrupole mass spectrometer that delivers excellent ion tr……...
Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……
SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……
AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……