[db:国别翻译]ChinaDayoptics,Inc.
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ 在Dayoptics Inc.上,我们的承诺是不断为客户提供最高的性能光学和……...

The DynaPro Zetastar is an instrument that combines measurements of dynamic and static light scattering (DLS/SLS) or dynamic and electrophoretic light scattering (DLS/ELS) simultaneously.
Microcuvette measurements can be carried out manually or automatically using a flow cell and an autosampler. This can swiftly evaluate parameters for characterization and stability investigations, including size, polydispersity, zeta potential, charge, particle concentration, molar mass, or turbidity.
Key Features
DYNAMICS Touch on-board application for self-directed, walk-up operation
With as little as 2 µL of solution, users can assess size and turbidity, or zeta potential with 65 µL of solution
Adaptive collection for zeta potential measurements that are quicker and easier
In buffers with conductivity up to two times physiological saline, measure the zeta potential
A variety of high-quality disposable cells, cuvettes, and quartz cells for zeta potential and size measurements
Specifications
Source:Waters | Wyatt Technology
| test | test |
|---|---|
| Pressure Range | Flow cell pressurizable to 400 psi for bubble suppression in conductive solvents |
| Optical System | Multiple optical channels: in-cuvette DLS & SLS, in-cuvette or flow cell DLS & ELS, fiber connection to Wyatt MALS detector for online DLS.ELS optical system: fiber-coupled interferometric Doppler electrophoretic light scattering (FIDELIS), determines electrophoretic mobility and zeta potential from frequency shift of scattered light |
| Refractive Index Range | N/A |
| Noise Level | N/A |
| Plate Formats | N/A |
| Measurement Mode(s) | ELS: electrophoretic mobility, zeta potential, electrical chargeDLS: size, size distributions, polydispersitySLS: particle concentration, molar mass, turbidity |
| Applications | Analysis of proteins, gene vectors, viruses and virus-like particles, promiscuous inhibitors, micelles, nano-emulsions, lipid and metallic nanoparticles, and more. |
| Linearity | SLS detector is linear over 6 decades |
| Principle | Dynamic Light Scattering (DLS), Electrophoretic Light Scattering (ELS), Static Light Scattering (SLS) |
| Sensitivity | DLS: 0.1 mg/mL of lyozymeELS: 1 mg/mL BSASLS: 0.1 mg/mL lysozyme |
| Measuring Range | Size: 0.2 nm to 1000 nm (hydrodynamic radius)Zeta potential: No practical limitMolecular weight: 300 Da to 1 MDa |
| Wavelength(s) | 785 nm |
| Type | Dynamic Light Scattering (DLS), Electrophoretic Light Scattering (ELS), Static Light Scattering (SLS) |
| Stability | N/A |
| Measuring Time | 15 seconds typical |
| Radius of Gyration Range | N/A |
| Detection System | DLS: Avalanche photodiode at 90º or 163.5º scattering angleSLS: photodiode at 90º scattering angleELS Detection: photodiode at 10º scattering angle for FIDELIS (fiber-interferometric Doppler electrophoretic light scattering) |
| Data Acquisition Rate | N/A |
| Sample Volume | Quartz Cuvette: 2 µL and 45 µLPEEK Flow Cell: 350 µLDip Cell: 65 µLDisposable DLS Cuvette: 4 µLDisposable Zeta Cell: 400 µL |
| Max. Flow Rate | N/A |
| Dimensions (WxDxH) | 36 x 57 x 20 cm |
| Shear Rate Range | N/A |
| Max. Pressure | N/A |
| Detector(s) | N/A |
| Temperature Range | -10 °C to +120 °C |
| Interface | DYNAMICS TOUCH onboard app or DYNAMICS Software on PC |
| Sample Type | Proteins, polymers, and nanoparticles including viruses, liposomes, gene vectors, nanoemulsions, etc. |
| Cell Volume | N/A |
| Control | Software control of detector and autosampler system to automate a series of unattended measurements |
| Particle Size | 0.2 to 1000 nm |
| Light Source | 785 nm laser, programmable 10% to 100% |
| Dynamic Range | N/A |
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ 在Dayoptics Inc.上,我们的承诺是不断为客户提供最高的性能光学和……...
Bruker’s latest e–FlashHD detector has a CCD resolution of almost 2 MP, which is equi……...
CenoStar Corporation is focused on the environmentally sustainable utilization of coal by-product……...
Meet today’s fluctuating commodity prices and soaring costs head on. Uncover opportunities ……...
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ DataPhysics Instruments在地表和界面科学领域提供了高质量和创新的……...
5200 Series Cap Lamps feature a smaller, Lexan headpiece which provides high impact resistance an……...
Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……
SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……
AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……