Dynamic Mechanical Analyzer (DMA) - NEXTA® DMA200

上海仪舶实验室自动化 25-01-23 15:53:44

Dynamic Mechanical Analyzer (DMA) - NEXTA® DMA200

The Dynamic Mechanical Analysis (DMA) method improves the sensitivity of measuringmaterial stiffness, glass transition, and the effect of frequency on mechanical properties. It measures a material’s viscoelastic characteristics.

DMA analyzers provide accurate measurements of mechanical properties for both basic and complicated materials, making them dependable for product engineers working in applied research and materials development.

With the help of its cutting-edge Real View® camera system, which provides real-time observation during measurements, the DMA can better analyze unforeseen behaviors such as color shifts and sample damage. Evenafter the measurement procedure is finished, it guarantees the validation of data point dependability.

TheDMA's extraordinarily broad measurement range and quick electronic response make it the ideal instrument for evaluating both soft and stiff samples and recording quick modulus changes.

Dynamic Mechanical Analyzer (DMA) - DMA7100

Image Credit: Hitachi High-Tech Analytical Science

Product Highlights

Comprehensive Material Characterization Made Easy

Video Credit: Hitachi High-Tech Analytical Science

For the analysis of stiff materials, such as carbon fiber composites and other high-performance materials, use the 20 N force range

The ability to access a wideapplied force range with low output signal noise and 5E–6N resolution enables the resolution and identification ofeven the smallest transitions

Select between air, liquid nitrogen (LN2), or electrical gas cooling. The LN2 cooling platform uses up to 30 % less energy than electrical gas cooling, which depends on power, removing external resources

Ensure confidence in the results byvalidating them during or after analysis using the Lissajous monitor function

The Real View system, numerous measuring modes, quick modulus change detection, and sophisticated analysis offer dynamic insights for research

Maximize convenience with the user-friendly ‘GuidanceMode’ software, delivering step-by-stepanalysis and measurementhelp for non-experts. Advanced options for various applications are included as standard, includingactivation energy calculations and master curves (TTS)

The DMA instrument adheres toISO, ASTM, DIN, and JIS standards, with crucial specifications incorporated into the software, includingISO 6721-11, ASTM D7028-07, IPC 2.4.24.2, JIS K7095, and more

What Makes the DMA Instruments Unique?

Real View® Camera for Visibly Better Thermal Analysis

Combined, the DMA200 and the Real View camera system workflawlessly, enablingreal-time observation of changes in the sample status during analysis. Changes in the sample’s size, shape, color, and other characteristics can be seen in high-resolution images. Images are captured and automaticallytimestamp-linked to the thermal analysis results, simplifyingimage processing and facilitating easysharing.

Optional Data Input and Output Software Package

Boost productivity and minimize human mistakes with the automatic measurement input. To make data management simpler and more dependable, use a barcode reader to enter crucial information such as name, method file, and lot number.

Product Specifications

Source: Hitachi High-Tech Analytical Science

. .
Deformation Mode Options Tension, single/dual cantilever, 3-point bending, shear, film-shear, compression​
Maximum Force 20 N
Modulus Range 103to 1013.5Pa
Frequency Sinusoidal wave oscillation: 0.01 to 200 Hz, max 20 frequencies​Synthesis wave oscillation mode: 5 frequencies​
Measurement Range 105to 1012Pa(Tension),105to 1012Pa(Dual-Cantilever Bending),103to 109Pa(Shear),104to 1010Pa(Film Shear),105to 109Pa(Compression),106.5to 1013.5Pa(3-Point Bending)
Temperature Range Liquid nitrogen cooling​-150 to 600 °C​Electrical gas cooling​-100 to 600 °CAir cooling​RT to 600 °C​
Sample Observation Real View®ready​
Driving shaft​ Spring mounted (no compressed air required)​
Sensor LVDT
Dimensions 420(W), x 630 (D) x 725(H) mm​

*Deformation modes "Bending", "Shear", "Film Shear", "Compression" and "3-Point Bending" are optional.

[Dynamic Mechanical Analyzer (DMA) - NEXTA® DMA200]相关推荐
Roland Electronic GmbH

Roland Electronic GmbH

Roland Electronic GmbH was founded in 1965 as subsidiary of Roland Sirenenbau GmbH, a company act……...

Lorin Industries

Lorin Industries

Lorin began back in 1943 as a plating company and then transitioned into a continuous coil anodiz……...

Intelvac

Intelvac

Originally started in 1967 as Canadian Vacuum Equipment (CVE), Intelvac has been serving the Cana……...

Petmin Limited

Petmin Limited

Petmin Limited is a growing multi-commodity mining and processing company and a market leader in ……...

今日仪器
  1. ANGEL BIT from Quarry Mining & Construction Equipment Pty Ltd

    ANGEL BIT from Quarry Mining & Construction Equipment Pty Ltd

    The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……

    仪器产品 2025-04-28

  2. Jetcrete Australia

    Jetcrete Australia

    Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……

    代理品牌 2025-04-28

  3. Borealis AG

    Borealis AG

    For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……

    代理品牌 2025-04-28

返回顶部小火箭