DLF-1200 Laser Flash Analysis: Flash Diffusivity Systems

上海仪舶实验室自动化 25-01-23 17:06:19

DLF-1200 Laser Flash Analysis: Flash Diffusivity Systems

TA Instruments provides a range of tools for measuring thermal diffusivity up to 1200°C using the flash method. This method enables the measurement of specific heat capacity and thermal conductivity of materials with numerous thermal properties.

All the tools from TA Instruments are provided with multi-specimen testing capability, thereby enabling improved productivity and enhanced specific heat capacity measurements. The tools are capable of full time pulse mapping, precision optics, and current data analysis, thus making the Discovery Flash platform a very precise system.

The Discovery Flash data analysis software consists of current methods for heat loss corrections. The Clark and Taylor method is used as the most precise basic purpose procedure for regulating thermal diffusivity based on the radiation heat losses, finite pulse width, and non-isothermal local sample conditions. There are more than 20 different analysis models and correction programs integrated into the software, thus providing maximum precision for all types of materials.

Available Models Include

Clark and Taylor

Moment

Degiovanni

Cowan

Koski

Least Squares

Logarithmic

Heckman

Parker

The detector used in the tools is designed specifically to suit the operating temperature range of the Environmental Module. In the case of moderate-to-high-temperature measurements, an indium antimonide (InSb) IR detector is used. The IR detector can be cooled with liquid nitrogen so as to ensure stable output and high repeatability.

Key Features

The main features of TA Instruments’ flash diffusivity systems are as follows:

Unparalleled precision of pulse-shape and pulse-width correction calculations and the most accurate determination of the t0

High sensitivity. quick response sensors

Precise measurement of transient temperature changes

Detector is factory-aligned to the sample and does not involve user exchange or alignment

Flash method is widely accepted and is documented in ASTM E2585, ASTM E1461, DIN EN821, DIN 30905,

[DLF-1200 Laser Flash Analysis: Flash Diffusivity Systems]相关推荐
ReGen III

ReGen III

ReGen III's patented ReGen™ process is the most technologically advanced re-refining p……...

Maxmile Technologies LLC

Maxmile Technologies LLC

MaxMile Technologies, LLC provides products and services in areas of electrical, optical and stru……...

Nilit Germany GmbH

Nilit Germany GmbH

Founded in 1969 by Ennio Levi, NILIT is committed to creating innovative, customized nylon (polya……...

ICON

ICON

Using proprietary 3D printing robotics, software and advanced materials, ICON is solving a plural……...

今日仪器
  1. Institute of Microelectronics

    Institute of Microelectronics

    Established in 1991, the Institute of Microelectronics (IME) is a research institute under Singapore’s Agency for Science, Technology and Research (A*STAR). In IME, we focus on delivering hig……

    代理品牌 2025-07-30

  2. Micropol Limited

    Micropol Limited

    Micropol is based in Stalybridge, Cheshire and has over 30 years experience in polymers. Out technical expertise is world class and out customers world wide. Our extensive in-house facilities allow……

    代理品牌 2025-07-30

  3. RAS Process Equipment

    RAS Process Equipment

    RAS Process Equipment , was established in 1977 and is committed to the design, engineering and manufacturing of quality process equipment for our customers. Equipment can be manufactured to the AS……

    代理品牌 2025-07-30

返回顶部小火箭