DLF-1200 Laser Flash Analysis: Flash Diffusivity Systems

上海仪舶实验室自动化 25-01-23 17:06:19

DLF-1200 Laser Flash Analysis: Flash Diffusivity Systems

TA Instruments provides a range of tools for measuring thermal diffusivity up to 1200°C using the flash method. This method enables the measurement of specific heat capacity and thermal conductivity of materials with numerous thermal properties.

All the tools from TA Instruments are provided with multi-specimen testing capability, thereby enabling improved productivity and enhanced specific heat capacity measurements. The tools are capable of full time pulse mapping, precision optics, and current data analysis, thus making the Discovery Flash platform a very precise system.

The Discovery Flash data analysis software consists of current methods for heat loss corrections. The Clark and Taylor method is used as the most precise basic purpose procedure for regulating thermal diffusivity based on the radiation heat losses, finite pulse width, and non-isothermal local sample conditions. There are more than 20 different analysis models and correction programs integrated into the software, thus providing maximum precision for all types of materials.

Available Models Include

Clark and Taylor

Moment

Degiovanni

Cowan

Koski

Least Squares

Logarithmic

Heckman

Parker

The detector used in the tools is designed specifically to suit the operating temperature range of the Environmental Module. In the case of moderate-to-high-temperature measurements, an indium antimonide (InSb) IR detector is used. The IR detector can be cooled with liquid nitrogen so as to ensure stable output and high repeatability.

Key Features

The main features of TA Instruments’ flash diffusivity systems are as follows:

Unparalleled precision of pulse-shape and pulse-width correction calculations and the most accurate determination of the t0

High sensitivity. quick response sensors

Precise measurement of transient temperature changes

Detector is factory-aligned to the sample and does not involve user exchange or alignment

Flash method is widely accepted and is documented in ASTM E2585, ASTM E1461, DIN EN821, DIN 30905,

[DLF-1200 Laser Flash Analysis: Flash Diffusivity Systems]相关推荐
Precision Tube Company

Precision Tube Company

Since 1932, when our first draw benches came to life, precision and quality have always been our ……...

Accustream Inc

Accustream Inc

To contribute to the waterjet community through engineering, manufacturing and the sale of waterj……...

Phillips Tube Group

Phillips Tube Group

Phillips Tube Group is the quality leader in the steel tube industry, meeting the requirements of……...

Laser Resale Inc

Laser Resale Inc

Laser Resale, Inc. provides a marketplace for the purchase and sale of used lasers, laser systems……...

WIT SRL

WIT SRL

Taiver is a leader company in the field of professional paint spraying equipments, spray guns and……...

今日仪器
  1. Thermo Scientific™ MarqMetrix™ All-In-One Process Raman Analyzer

    Thermo Scientific™ MarqMetrix™ All-In-One Process Raman Analyzer

    Video credit: Thermo Fisher Scientific Using the Thermo Scientific™MarqMetrix™All-in-One Process Raman Analyzer, organizations have the ability to perform instantaneous, non-invasive a……

    仪器产品 2025-06-15

  2. Revealing Natural States of Materials with Environmental Scanning Electron Microscopy (ESEM)

    Revealing Natural States of Materials with Environmental Scanning Electron Microscopy (ESEM)

    The Thermo Scientific Quattro ESEM offers comprehensive performance in both imaging and analytics, featuring a distinctive environmental mode (ESEM) that enables the examination of samples in their……

    仪器产品 2025-06-15

  3. Opti-Forms, Inc.

    Opti-Forms, Inc.

    Opti-Forms is a designer and manufacturer of electroformed optical reflectors, coldshields, mechanical assemblies and the application of high performance specialty thin film coatings for the commer……

    代理品牌 2025-06-15

返回顶部小火箭