TESCAN SEM/FIB-SEM with Integrated Raman Spectrometry
The fully-integrated correlative Raman imaging and scanning electron microscopy designed by TESCA……...
Features
Bright 60 or 100 mm (2.3 or 4") red or green digits
Full NEMA 4 (IP65) metal enclosure
Wall suspension or panel mount
Control, alarm and retransmission capability with field installable cards
Power options of 85 to 260 Vac and 11 to 36 Vdc. Sensor power built-in where required.
Temperature: thermocouples K, T, J, E, R, S, N, C; RTD/Pt100
Display of current, max or min values
Clock: time, timer with start, stop and reset
Remote display: ASCII RS232, RS485, Modbus RTU
Process: 4 to 20 mA, 0 to 20 mA, ±10 Vdc, 0 to 10 Vdc
Rate, total, count, period: PNP, NPN, Namur, Inductive, TTL, Quadrature
Ideal for informing customers and colleagues of key information
Time keeping, productivity, targets, output, incident free days
Product/piece counting or production rate indication
Description
The LDB Series of large displays offer a wide range of display, measurement and alarm capabilities for all types of commercial and industrial applications. Data is visible by a large audience at distances of up to 50 m (160').
These displays offer the ability to provide control, alarms, and/or retransmission of measured data. Field-installable options are also available for analog retransmission signals, transistor or relay outputs, SSR controls, as well as communications in Modbus RTU, RS232 or RS485 ASCII protocols. For reliable performance and protection, all circuits are isolated.
The LDB series includes a full NEMA 4 (IP65) metallic housing, and can be wall mounted, panel mounted or suspended. Easy configuration is possible using the front keypad, while an optional remote keypad is also available.
The front lens is made using anti-reflective tinted methacrylate. This allows sharp and clear reading, even at long distances. In addition, adjustments in brightness are possible, with 5 levels of LED brightness available to suit most environments.
Specifications
Display Digits & Range: Six 999999/-199999 or four 9999/-1999
Decimal Point: Configurable
LED Color: Red standard; Green optional
Digit Height: 60 mm (2.36") or 100 mm (4")
Operating Temperature: 0 to 50 °C (32 to 122 °F)
Storage Temperature: -20 to 70 °C (-4 to 158 °F)
Connections: Plug-in screw terminal
Signal Wire Diameter: Max. 0.5 mm²
Power Wire Diameter: Max. 2.5 mm²
Process Meter
Signal Ranges: 4 to 20 mA, 0 to 10 Vdc, ±20 mA, ±10 Vdc
Excitation Voltage: 20 Vdc, 15 Vdc, 10 Vdc, 5 Vdc (max. 35 mA)
Accuracy: 0.05% F.S. ±1 digit
Offset Drift: 10 ppm/ºC
Span Drift: 25 ppm/ºC (includes offset drift)
Read Rate: 15 readings/second
Refresh Rate: 15/second
Response Time: <120 mSec. (0 to 99% signal)
Input impedance: 11 Ohm for mA, 932 k(O) for Vdc
Temperature Meter (4-Digit Only)
Pt100: 2 or 3 wire
Resolution: 1º or 0.1º
Measuring Range: 800 to -200 ºC (1472 to -328 ºF)
Accuracy: ±0.2º
Cable Compensation: Automatic up to 14 Ω
Offset Drift: 0.05%
Span Drift: 0.10% (includes offset drift)
Thermocouples: J, K, T, E, S, R, N, C, L
Resolution: 1º
Measuring Ranges: See user manual
Accuracy: ±2º to ±4º depending on thermocouple type
Thermocouple Cold Junction: Automatic (configurable)
Offset Drift: 0.05 to 0.2%
Span Drift: 0.02 to 0.2% (includes offset drift)
Rate, Total Meter
Signals Accepted: NPN, PNP, Namur, pick-up, TTL, inductive, mechanical, quadrature
Excitation Voltage: 5 Vdc, 9 Vdc, 15 Vdc, 18 Vdc (max. 70 mA)
Maximum Vdc at Input Terminals: ±30 Vdc
Quartz Accuracy: ±0.01%
Thermal Stability: 20 ppm/ºC
Display Refresh: 15/second
Maximum Frequencies:
Counter: up to 250 KHz
Rate Meter and Period: meter up to 500 KHz
Minimum Frequencies: Rate meter and period meter down to 1 mHz (0.001 Hz)
Clock, Timer, Chronometer
Reading, Formats:
4-Digit: mm.ss, hh.mm, dd.hh, ssss, sss.s, ss.ss, mmmm, mmm.m, mm.mm, hhhh, hhh.h, hh.hh
6-Digit: mm.ss.cc, hh.mm.ss, dd.hh.mm, mmmm.ss, hhhh.mm, dddd.hh, ssssss, sssss.s, ssss.ss, mmmmmm, mmmmm.m, mmmm.mm, hhhhhh, hhhhh.h, hhhh.hh (c=1/100 sec, s=sec., m=min., h=hour, d=day)
Counting Direction: Up, down
Controls: Start, stop, reset
Control Activation: Volt-free contact (default), configurable for push-pull, NPN, PNP, inductive
Maximum Vdc at Input Terminals: ±30 Vdc
Reset Control: Remote, front panel and on alarm
Accuracy: 100 ppm
Display Refresh: 12/second, reading memory maintained in case of power loss
Modbus RTU, RS485, RS232 Meter
Common:
Speed: 38,400 bps to 600 bps
Data Format: 8n1, 8e1, 8o1,8n2, Bus terminator not included, Watchdog configurable from 1 to 120 seconds
Modbus RTU:
Bus: RS485
Function: “slave” for Modbus RTU protocol
Addresses: 1 to 247
RS485:
Protocol: ASCII
Bus: RS485
Function: Repeater for ASCII code
Addresses: 1 to 31
RS232:
Protocol: ASCII
Bus: RS232
Function: Repeater for ASCII code
Addresses: 1 to 31 (“daisy-chain” connections)
The fully-integrated correlative Raman imaging and scanning electron microscopy designed by TESCA……...
The Discovery Hybrid Rheometer (DHR) from TA Instruments can now characterize the behaviors of po……...
Wafer handling stages from Prior Scientific are engineered to be integrated with specially design……...
A leading multinational chemical distribution company with subsidiaries in Europe, Asia and North……...
Rutgers, The State University of New Jersey (also known as Rutgers University), is the largest in……...
INTEGRATED HARDNESS TESTER TH170 is an upgraded new model of TH130. The increased function comp……...
Established in 1991, the Institute of Microelectronics (IME) is a research institute under Singapore’s Agency for Science, Technology and Research (A*STAR). In IME, we focus on delivering hig……
Micropol is based in Stalybridge, Cheshire and has over 30 years experience in polymers. Out technical expertise is world class and out customers world wide. Our extensive in-house facilities allow……
RAS Process Equipment , was established in 1977 and is committed to the design, engineering and manufacturing of quality process equipment for our customers. Equipment can be manufactured to the AS……