Automatic Extensometer – Models AE300 and AE500
The extensometer models AE500 and AE300 are ideal for nearly all samples with an initial gauge le……...
The spatially resolved capillary inlet MS (SpaciMS) from Hiden Analytical enables both axial and radial species determination and temperature profiles, with high spatial and temporal resolution and with very minimal interference in temperature or flow. The 16-channel multi-inlet is connected to Hiden’s quick transient MS to offer automatic and quick mapping of temperature and species distributions.
Applications
Catalysis
Hiden’s SpaciMS is the first commercial instrument of its type on the market.
Originally invented and developed by scientists at the Oak Ridge National Laboratory and Cummins, Inc. to study diesel catalysis, the SpaciMS inlet has been developed further for an entire range of applications.
The 16 thermocouples and capillary sampling probes are assembled in an X-Y array. A Z-shift offers movement and precise positioning of the array in the Z plane. In general, the 16 capillary sampling probes are examined consecutively by the MS.
Then, the Z-shift is actuated to move the sampling probe array to the consecutive incremental Z position and the analysis sequence is thus repeated. Once the analysis is completed, the analytical data offers a spatial representation of temperature and sample gas composition of the volume sealed within the X-Y array over the entire incremental Z distance moved.
Features
16-capillary inlet system
Minimally invasive
Z-Drive is provided for positioning of inlet positions
High temporal distribution
Sampling stream position is software-controlled
3D Mapping of intra-reactor gas composition
Thermocouple inputs for temperature measurement at sampling point
SpaciMS Schematic
Image Credit: Hiden Analytical
The integrated z-motion drive moves the capillaries that are inserted into the catalyst monolith.
SpaciMS Probe Layout
Image Credit: Hiden Analytical
Twin Inlet SpaciMS
The dual-inlet SpaciMS enables sampling of inlet or outlet gas composition of diesel particulate filters.
Image Credit: Hiden Analytical
SpaciMS Probe
Image Credit: Hiden Analytical
SpaciMS Analysis
Image Credit: Hiden Analytical
The SpaciMS enables the mapping of reaction profiles within the catalyst and not only at the exhaust.
Image Credit: Hiden Analytical
The intra-catalyst probes enable different catalyst reaction zones to be monitored.
The extensometer models AE500 and AE300 are ideal for nearly all samples with an initial gauge le……...
As market demand drives electronics companies to pack more performance and functionality into chi……...
Vimetco is a globally integrated aluminium Group, with bauxite mines in Sierra Leone, coal mines,……...
The University of Arizona is a place of wonder where you can do the extraordinary with extraordin……...
Since 1917, Superior Graphite has been committed to enhancing our ability to adapt to ever-changi……...
Red Metal Resources Ltd., based in Thunder Bay, Ontario, is an aggressive exploration company foc……...
The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……
Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……
For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……