Determining Intra Catalyst Reactor Chemistry with SpaciMS

上海仪舶实验室自动化 25-01-23 15:36:10

Determining Intra Catalyst Reactor Chemistry with SpaciMS

The spatially resolved capillary inlet MS (SpaciMS) from Hiden Analytical enables both axial and radial species determination and temperature profiles, with high spatial and temporal resolution and with very minimal interference in temperature or flow. The 16-channel multi-inlet is connected to Hiden’s quick transient MS to offer automatic and quick mapping of temperature and species distributions.

Applications

Catalysis

Hiden’s SpaciMS is the first commercial instrument of its type on the market.

Originally invented and developed by scientists at the Oak Ridge National Laboratory and Cummins, Inc. to study diesel catalysis, the SpaciMS inlet has been developed further for an entire range of applications.

The 16 thermocouples and capillary sampling probes are assembled in an X-Y array. A Z-shift offers movement and precise positioning of the array in the Z plane. In general, the 16 capillary sampling probes are examined consecutively by the MS.

Then, the Z-shift is actuated to move the sampling probe array to the consecutive incremental Z position and the analysis sequence is thus repeated. Once the analysis is completed, the analytical data offers a spatial representation of temperature and sample gas composition of the volume sealed within the X-Y array over the entire incremental Z distance moved.

Features

16-capillary inlet system

Minimally invasive

Z-Drive is provided for positioning of inlet positions

High temporal distribution

Sampling stream position is software-controlled

3D Mapping of intra-reactor gas composition

Thermocouple inputs for temperature measurement at sampling point

SpaciMS Schematic

SpaciMS Schematic

Image Credit: Hiden Analytical

The integrated z-motion drive moves the capillaries that are inserted into the catalyst monolith.

SpaciMS Probe Layout

SpaciMS Probe Layout

Image Credit: Hiden Analytical

Twin Inlet SpaciMS

The dual-inlet SpaciMS enables sampling of inlet or outlet gas composition of diesel particulate filters.

Twin Inlet SpaciMS

Image Credit: Hiden Analytical

SpaciMS Probe

SpaciMS Probe

Image Credit: Hiden Analytical

SpaciMS Analysis

SpaciMS Analysis

Image Credit: Hiden Analytical

The SpaciMS enables the mapping of reaction profiles within the catalyst and not only at the exhaust.

SpaciMS Analysis

Image Credit: Hiden Analytical

The intra-catalyst probes enable different catalyst reaction zones to be monitored.

[Determining Intra Catalyst Reactor Chemistry with SpaciMS]相关推荐
Niko Resources Ltd.

Niko Resources Ltd.

Niko Resources Ltd. engages in the exploration, development, and production of natural gas and oi……...

InEight

InEight

InEight provides field-tested project management software for the owners, contractors, engineers ……...

今日仪器
  1. Thermo Scientific™ MarqMetrix™ All-In-One Process Raman Analyzer

    Thermo Scientific™ MarqMetrix™ All-In-One Process Raman Analyzer

    Video credit: Thermo Fisher Scientific Using the Thermo Scientific™MarqMetrix™All-in-One Process Raman Analyzer, organizations have the ability to perform instantaneous, non-invasive a……

    仪器产品 2025-06-15

  2. Revealing Natural States of Materials with Environmental Scanning Electron Microscopy (ESEM)

    Revealing Natural States of Materials with Environmental Scanning Electron Microscopy (ESEM)

    The Thermo Scientific Quattro ESEM offers comprehensive performance in both imaging and analytics, featuring a distinctive environmental mode (ESEM) that enables the examination of samples in their……

    仪器产品 2025-06-15

  3. Opti-Forms, Inc.

    Opti-Forms, Inc.

    Opti-Forms is a designer and manufacturer of electroformed optical reflectors, coldshields, mechanical assemblies and the application of high performance specialty thin film coatings for the commer……

    代理品牌 2025-06-15

返回顶部小火箭