DECTRIS PILATUS4 R CdTe detectors allow quick data collection with their large active area of up to 155 × 162 mm andhigh quantum efficiency (over 95%)using any X-Ray source from Cu to In. For Ag, Mo, and In radiation, PILATUS4 R CdTe outperforms any HPC detector with a Si sensor—even PILATUS3, which has the thickest Si sensor available.
A dynamic range that spans 10 orders of magnitude is attained via PILATUS4’s superior count rates and the lack of detector background. Internal frame rates of up to 200 Hz enhance the count-rate correction and guarantee highly precise measurement of extreme intensities. PILATUS4 provides fresh possibilities in spectral imaging and Laue diffraction using four energy-discriminating thresholds.
Large andefficient: Active regions of a maximum of 155 × 162 mm, with a quantum efficiency of over 95%
Due to superior count rates, zero detector background, and concurrent read/write, the most extensive possible dynamic range is available.
Versatile: For polychromatic applications, four energy-discriminating thresholds are available; High quantum efficiency from Cu to In also exists
DECTRIS PILATUS4 R CdTe Detectors*
Source: DECTRIS AG
| PILATUS4 R CdTe1M | PILATUS4 R CdTe260K | PILATUS4 R CdTe 260K-W | |
|---|---|---|---|
| Active area(W x H) [mm²] | 155.0 x 162.0 | 77.0 x 79.5 | 155.0 x 38.3 |
| Pixel array(W x H) | 1033 x 1080 | 513 x 530 | 1033 x 255 |
| Pixel size(W x H) [µm²] | 150 x 150 | ||
| Energy range [keV] | 8 - 25(8 - 100)1 | ||
| Number of energythresholds | 4 | ||
| Threshold range [keV] | 4 - 30(4 - 80)1 | ||
| Count rate[ph/s/pixel] | 5.0 * 106 | ||
| Frame rate1(max.) [Hz] | 10 | 100 | 100 |
| Readout time2 | Continuous readout | ||
| Sensor material | Cadmium telluride (CdTe) | ||
| Sensor thickness [µm] | 1000 | ||
| Point-spread function(FWHM) [pixels] | 1 | ||
| Dimensions(W x H x D) [mm3] | 235 x 237 x 372 | 114 x 133 x 242 | 114 x 92 x 242 |
| Weight [kg] | 15 | 4.7 | 4.7 |
*All specifications are subject to change without notice.1With optional calibration for an extended energy range.2The effective dead time between exposures is <100 ns (max. loss of 1 count/pixel).
H.E.L’s fully customizable AutoLAB reactor platforms are designed, configured, and tailored……...
Alexium的核心业务是开发尖端化学解决方案,并快速将其应用于商业领域。 Alexium在澳大利亚、美国和欧……...
Imaging of microscopic samples in the UV-visible-NIR region-now with Raman microspectroscopy! The……...
As one aluminum Supplier headquartered in Shanghai, Sino Unicorn International Co., Limited is sp……...
Die Cast Of America 专注于小型、中型和大型压铸业务。公司提供全方位的二次加工,以实现“直接流水线……...
The Martindale Abrasion and Pilling Tester, featuring TestWise Touch™ software by James Hea……...
Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……
SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……
AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……