Infloor Heating Systems
Infloor Heating Systems has been in business since 1982 and has been providing quality radiant he……...
DataAnalyst is a supporting software suite for Lasair Pro, Lasair III, and MiniCapt Mobile devices, facilitating seamless connectivity for data downloading, archiving, and reporting while ensuring full compliance with secure data transfer protocols.
The program accommodates a diverse range of installation setups, spanning from individual base stations to integrated networks encompassing multiple Lasair Pro, Lasair III, and MiniCapt Mobile instruments linked to a LAN for efficient distribution and reporting.
Its robust reporting framework operates in conjunction with specific inputs from the particle counter, filtering sampling data based on factors such as location, date/time, or product batch information. Reports generated can be tailored to meet industry standards and configured to incorporate raw and tabular data in both statistical and graphical formats.
Furthermore, the reporting tool offers flexibility by allowing configuration for various report formats, including certification adherence to ISO 14644-1:2015, FDA, EU GMP, or FS 209 standards. Integration with MiniCapt Mobile microbial samplers enables the collection, storage, and reporting of sampling data.
The manual data entry feature empowers authorized users to input CFU counts, incubation temperature, and incubation time. This comprehensive functionality allows all cleanroom classification and monitoring data to reside within a singular, secure, and validated program.
Benefits
Cleanroom certification reports are in accordance with ISO 14644-1:2015, FDA, EU GMP, and FS 209E standards
Lasair Pro and Lasair III particle counters, along with MiniCapt Mobile microbial samplers, benefit from long-term data archiving capabilities
The system is compliant with 21 CFR Part 11, ensuring data security and integrity
A centralized SQL Server® database facilitates access to all data and reports from Lasair Pro and Lasair III particle counters, as well as MiniCapt Mobile microbial samplers, across a site-wide LAN
Instrument data can be easily downloaded with a single click from a configured instrument
Secure data export is possible through the USB port on the Lasair III and via Ethernet connections on the Lasair Pro and MiniCapt Mobile
The software's enhanced security features accommodate Windows Active Directory ID/password management
Features
Designed to work seamlessly with Lasair III and MiniCapt Mobile devices
Streamlined report filtering and configuration for simplicity
Features an intuitive tabular design for user-friendly navigation
Maintains a comprehensive audit trail for full transparency
Swift security configuration allows for the addition of new users and customization of groups
Applications
Retrieving data from Lasair Pro, Lasair III, and MiniCapt Mobile devices
Analyzing trends in cleanroom certification and contamination
Monitoring and reporting for cleanroom compliance
Reporting on microbial activity
Generating cleanroom certification reports using Lasair Pro and Lasair III particle counters
Monitoring and reporting on process tool performance
Source: Particle Measuring Systems
. | . |
---|---|
PC compatibility | Please refer to the Microsoft® operating system minimum requirements. |
Memory | 2 GB RAM, minimum |
Hard disk | 64 GB free hard drive space for the data archives, message files, buffer files, and log files used by the system |
Network | TCP/IP-compatible network adapters are acceptable |
Operating systems | Microsoft Windows 10 |
Database compatibility | Microsoft SQL Server® 2014 Express SP1 or Standard edition |
Instrument compatibility | DataAnalyst version 4.x and newer is compatible with Lasair® IIIparticle counter running firmware version 2.1.008 or newer, Lasair® Pro running firmware version 1.01.015 or newer, MiniCapt® Mobile running firmware version 2.0.0.0/1.1/1.3.0.0, and MiniCapt® Mobile Refresh running firmware version 3.0.0.1/2.0/2.1.0.0 or newer. |
Interactive charts. Image Credit: Particle Measuring Systems
Data view with multiple instruments configured to facilitate quick downloads. Image Credit: Particle Measuring Systems
Certification report. Image Credit: Particle Measuring Systems
Infloor Heating Systems has been in business since 1982 and has been providing quality radiant he……...
Soilmoisture Equipment Corp. is Manufacturer of instruments to measure and extract soil moisture.……...
RF VALVES has three headquarters: American (USA), European (Finland), and South Africa which enab……...
Applied Energy Systems (AES) is the premier gas delivery equipment and systems provider, engineer……...
Barton Blakeley Technologies is an Applied Sciences Organisation based in Harpenden, Hertfordshir……...
In high-end research AFM, performance and flexibility are the top design criteria. Common UHV SPM……...
The Angel Drill Bit provides improved safety by decreasing liklihood of mesh entanglement. Features: Available in 27 and 28mm M16 Successfully trialled in NSW coal mines Minimises risk of entanglem……
Jetcrete Australia is the largest specialised shotcrete contractor in Australia and has been successfully operating for over 28 years with current projects throughout WA and the Eastern States, pro……
For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……