With a fixed particle counter, the AM II manifold provides sophisticated features for sequentially monitoring aerosol contamination at several locations. When ongoing monitoring is not required, the AM II is perfect for trend analysis and cleanroom verification.
Control Box. Image Credit: Particle Measuring Systems
Manifold Pump. Image Credit: Particle Measuring Systems
Manifold Module. Image Credit: Particle Measuring Systems
Compatibility
Lasair® II or Lasair III particle counters, or IsoAir® PLUS particle sensor
Benefits
Cost Effective
Cost-effective monitoring of fixed pointsat timed intervals
Minimal cost per sample location
More expansive monitoring area compared to a stationary particle counter
Communication via Ethernet to the facility monitoring system
Flexibility
Programs a sampling routine easily for both simple and complex sequences
Alters sampling recipe automatically upon receiving an external signal or alarm
Large coverage area: every sample point can be up to 125 feet away
Accurate and Rapid Measurements
Patented flow control ensures that the manifold compensates for manifold pressure drop, removing systematic particle undercounting of up to 15 %
Reduces gravitational particle settlingby maintaining a steady flow (nominal 3 CFM) at each sample point
Distortion in particle size relationshipsis prevented using isokinetic sampling probes, which collect particles at the same velocity as sample air
Features
Multiplex monitoring of up to 32 sites using a single particle counter
Managed by thePharmaceutical Net orFacility Net software
Programmable recipes and sample point sequences
Assembly designed to remove contaminationfrom the valves
Alarm for low vacuum; automatic shut-off for pump overheating
Applications
Facility monitoring
Monitoring large mini-environments
Cleanroom verification and trend analysis
Specifications
Source: Particle Measuring Systems
Manifold System | AM II-16 | AM II-32 |
---|---|---|
Sample ports | Max. 16, Min. 10 | Max. 32, Min. 22 |
Operatingrange | Use in locations ISO 8 (Class 100,000) or cleaner0.1 to 0.3 μm particle counters: Use to simultaneously monitor ISO 3, 4, 5, and 6 (Classes 1, 10, 100, 1000)0.5 to 5.0 μm particle counters: Use to simultaneously monitor ISO 5, 6, 7, and 8 (Classes 100, 1000, 10,000, 100,000) | |
Manifold Pump | ||
Pumps required | 1 (single-phase) | 1 (3-phase) |
Flow rate | > 100 ft3/min | > 150 ft3/min |
Safety provision | Automatic pump shutoff | Automatic pump shutoff |
Power | 105 – 125 VAC, 60 Hz or 220-240 VAC, 50 Hz 10.9 Amp, single-phase | 415 – 480 VAC, 60 Hz5.0 Amp, 3-phase |
Dimensions(l, w, h); weight | 10.6 x 11.2 x 16.2 in (27 x28 x 41 cm); 42 lb (19 kg) | 16.7 x 15.0 x 20.0 in (47 x38 x 51 cm); 75 lb (34 kg) |
Manifold Module | ||
Flow rate | 1.5 – 3 CFM per port (nominal) |
System Components Included:Manifold module, control box, pump, operations manual, power cord, control cable, wall-mounting bracket, monitor exhaust tubing, pressure sensor tubing, pump tubing, and clamps.Not included:Particle counter/sensor, ISPs, sample tubing, communications cables (manifold to counter/sensor), PC, Facility Net or Pharmaceutical Net software. |
Purge time(between ports) | 15 seconds recommended | |
Cross talk (from other ports) | < 0.1 % | |
Sample tubing | Bev-A-Line XX® 1/2” OD, 3/8” ID (part # MI-153) | |
Sample tubing length and bend | 25’ – 125’ per port. Minimum 9” radius for Bev-A-Line XX® | |
Fittings provided | 16 (or 32) self-locking, 1/2” OD, Legris® (L-Legris) fittings | |
Vacuum required | 30” – 55” water | |
Mounting orientation | Vertical; wall mounting bracket included | |
Power | Provided by control box via controller cable | |
Dimensions(l, w, h); weight | 13.5 x 13.5 x 15.3 in (34 x 34 x 39 cm); 13.5 lb (6.1 kg) | |
Control Box | ||
Controllingsoftware | Facility Net/Pharmaceutical Net (purchased separately) | |
Communications protocol | Ethernet | |
Firmware setup modes | RS-232, Telnet | |
Ethernet outlets (2) | Network/Primary sensor | |
Automatic alarm | Inadequate manifold vacuum | |
Mounting | Vertical or horizontal; built-in mounting holes | |
Power | 105 – 125 VAC, 60 Hz; 220 – 240 VAC, 50 Hz | |
Dimensions(l, w, h); weight | 7 x 8.5 x12.5 in (18 x 22 x 32 cm); 11.5 lb (5.2 kg); painted steel box | |
System operating conditions | Temperature: 59 – 95 ° (15 – 35 °C); Humidity: non-condensing |
The OMNIS NIR Analyzer series comprises state-of-the-art, Swiss-made laboratory instruments desig……...
The Pointprobe� is a versatile silicon AFM probe for very high resolution imaging and fits to a……...
GLEN MILLS Inc is a North American distributor of a comprehensive range of sample preparation equ……...
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ Incorporated的Koral Labs提供了30年的薄膜溅射服务。 Koral的创始……...
Freedom Equpiment is an innovative company that offers low cost alternatives to new machinery. Ou……...
/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ 测量和机器技术提供机器工具对齐,激光校准和维修服务。 近40年来……...
Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……
SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……
AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……