Cost-Effective AM II-16/32 for Aerosol Monitoring

上海仪舶实验室自动化 25-03-28 13:56:42

Cost-Effective AM II-16/32 for Aerosol Monitoring

With a fixed particle counter, the AM II manifold provides sophisticated features for sequentially monitoring aerosol contamination at several locations. When ongoing monitoring is not required, the AM II is perfect for trend analysis and cleanroom verification.

Control Box.

Control Box. Image Credit: Particle Measuring Systems

Manifold Pump.

Manifold Pump. Image Credit: Particle Measuring Systems

Manifold Module.

Manifold Module. Image Credit: Particle Measuring Systems

Compatibility

Lasair® II or Lasair III particle counters, or IsoAir® PLUS particle sensor

Benefits

Cost Effective

Cost-effective monitoring of fixed pointsat timed intervals

Minimal cost per sample location

More expansive monitoring area compared to a stationary particle counter

Communication via Ethernet to the facility monitoring system

Flexibility

Programs a sampling routine easily for both simple and complex sequences

Alters sampling recipe automatically upon receiving an external signal or alarm

Large coverage area: every sample point can be up to 125 feet away

Accurate and Rapid Measurements

Patented flow control ensures that the manifold compensates for manifold pressure drop, removing systematic particle undercounting of up to 15 %

Reduces gravitational particle settlingby maintaining a steady flow (nominal 3 CFM) at each sample point

Distortion in particle size relationshipsis prevented using isokinetic sampling probes, which collect particles at the same velocity as sample air

Features

Multiplex monitoring of up to 32 sites using a single particle counter

Managed by thePharmaceutical Net orFacility Net software

Programmable recipes and sample point sequences

Assembly designed to remove contaminationfrom the valves

Alarm for low vacuum; automatic shut-off for pump overheating

Applications

Facility monitoring

Monitoring large mini-environments

Cleanroom verification and trend analysis

Specifications

Source: Particle Measuring Systems

Manifold System AM II-16 AM II-32
Sample ports Max. 16, Min. 10 Max. 32, Min. 22
Operatingrange Use in locations ISO 8 (Class 100,000) or cleaner0.1 to 0.3 μm particle counters: Use to simultaneously monitor ISO 3, 4, 5, and 6 (Classes 1, 10, 100, 1000)0.5 to 5.0 μm particle counters: Use to simultaneously monitor ISO 5, 6, 7, and 8 (Classes 100, 1000, 10,000, 100,000)
Manifold Pump
Pumps required 1 (single-phase) 1 (3-phase)
Flow rate > 100 ft3/min > 150 ft3/min
Safety provision Automatic pump shutoff Automatic pump shutoff
Power 105 – 125 VAC, 60 Hz or 220-240 VAC, 50 Hz 10.9 Amp, single-phase 415 – 480 VAC, 60 Hz5.0 Amp, 3-phase
Dimensions(l, w, h); weight 10.6 x 11.2 x 16.2 in (27 x28 x 41 cm); 42 lb (19 kg) 16.7 x 15.0 x 20.0 in (47 x38 x 51 cm); 75 lb (34 kg)
Manifold Module
Flow rate 1.5 – 3 CFM per port (nominal)

System Components Included:Manifold module, control box, pump, operations manual, power cord, control cable, wall-mounting bracket, monitor exhaust tubing, pressure sensor tubing, pump tubing, and clamps.Not included:Particle counter/sensor, ISPs, sample tubing, communications cables (manifold to counter/sensor), PC, Facility Net or Pharmaceutical Net software.

Purge time(between ports) 15 seconds recommended
Cross talk (from other ports) < 0.1 %
Sample tubing Bev-A-Line XX® 1/2” OD, 3/8” ID (part # MI-153)
Sample tubing length and bend 25’ – 125’ per port. Minimum 9” radius for Bev-A-Line XX®
Fittings provided 16 (or 32) self-locking, 1/2” OD, Legris® (L-Legris) fittings
Vacuum required 30” – 55” water
Mounting orientation Vertical; wall mounting bracket included
Power Provided by control box via controller cable
Dimensions(l, w, h); weight 13.5 x 13.5 x 15.3 in (34 x 34 x 39 cm); 13.5 lb (6.1 kg)
Control Box
Controllingsoftware Facility Net/Pharmaceutical Net (purchased separately)
Communications protocol Ethernet
Firmware setup modes RS-232, Telnet
Ethernet outlets (2) Network/Primary sensor
Automatic alarm Inadequate manifold vacuum
Mounting Vertical or horizontal; built-in mounting holes
Power 105 – 125 VAC, 60 Hz; 220 – 240 VAC, 50 Hz
Dimensions(l, w, h); weight 7 x 8.5 x12.5 in (18 x 22 x 32 cm); 11.5 lb (5.2 kg); painted steel box
System operating conditions Temperature: 59 – 95 ° (15 – 35 °C); Humidity: non-condensing
[Cost-Effective AM II-16/32 for Aerosol Monitoring]相关推荐

[db:国别翻译]美国Kassoy LLC

/9-9-I-9M-9M-9-9A-9-9G-9G-9E-1/ 75年来,卡索伊(Kassoy)一直为零售珠宝商,宝石学家,学徒,工匠……...

Metrios

Metrios

Metrios designs and manufactures optical measuring machines. We don't have the ambition to p……...

Redwood Plastics

Redwood Plastics

Redwood Plastics has worked directly with customers to find solutions for a variety of problems i……...

今日仪器
  1. Item North America

    Item North America

    Item North America is a premier provider of precision ball screws for use as a drive mechanism in linear slides, multi-axis motion and complex material handling devices. item ball screws feature hi……

    代理品牌 2025-09-04

  2. Streaming Answers: SurPASS™ 3

    Streaming Answers: SurPASS™ 3

    SurPASS™ 3 is capable of measuring the zeta potential over an extensive range of materials and allows the analysis of varied surface properties and their changes. The zeta potential explains ……

    仪器产品 2025-09-04

  3. AHP Materials

    AHP Materials

    AHP Materials is a specialty materials company focused on the manufacturing and selling of high purity specialty metals and compounds. AHP concentrates mainly on Antimony, Cadmium Sulfide, Telluriu……

    代理品牌 2025-09-04

返回顶部小火箭