Hi Tech Automation
Hi-Tech Automation formed by Ricky Thompson and Gary Probert in 1996, which created for the first……...
Clarion-96 Gel Filtration plates are utilized for high-throughput desalting and removing small molecular weight impurities through centrifugation with a swinging bucket rotor.
Using a two- to three-minute centrifugation technique, proteins, oligos, or nanoparticles are concurrently purified, desalted, and eluted into clean water.
Clarion-96 Gel Filtration Plates Features:
Each gel bed is supported on an individual ultra-high molecular weight PE filter membrane with a pore size of 25 microns
Hydrated with sterile purified water without preservatives, salts, or buffers
Precision filled with SorbaDex™, a beaded composite material comprised of ultrapure cross-linked dextran
The filtration plate is made from sterile medical-grade polypropylene, supplied ready-to-use
Well volumes available from 140 to 1000 µL, sample volume capacity from 10 to 40 µL
Available in both 96 and 384 ANSI-SBS standard format
Specifications
Source: Sorbent Technologies, Inc.
Catalog# | # Wells | Well Vol. | Plate Height | Max Sample Vol. | Gel Bed Vol. | Matrix | Drip Directors | For Proteins/NucleicAcids Greater Than | Mode of Operation |
---|---|---|---|---|---|---|---|---|---|
Clarion™ 384-135LD50 Gel_Filtration Plate 135 μL Well Volume | |||||||||
802009 | 384 | 140 µL | 15 mm | 10 µL | 100 µL | S50-SF | Long | 25 kD/20 bases | Centrifuge 3 minutes at 1000xG |
Clarion™ 96-400SD50 Gel_Filtration Plate 400 μL Well Volume | |||||||||
802002 | 96 | 400 µL | 20 mm | 20 µL | 320 µL | S50-SF | Short | 25 kD/20 bases | Centrifuge 3 minutes at 1000xG |
Clarion™ 96-400LD50 Gel_Filtration Plate 400 μL Well Volume | |||||||||
802003 | 96 | 400 µL | 20 mm | 20 µL | 320 µL | S50-SF | Long | 25 kD/20 bases | Centrifuge 3 minutes at 1000xG |
Clarion™ 96-800SD50 Gel_Filtration Plate 800 μL Well Volume | |||||||||
802004 | 96 | 800 µL | 31 mm | 30 µL | 400 µL | S50-SF | Short | 25 kD/20 bases | Centrifuge 3 minutes at 1000xG |
Clarion™ 96-800SD25 Gel_Filtration Plate 800 μL Well Volume | |||||||||
802005 | 96 | 800 µL | 31 mm | 30 µL | 400 µL | S25-SF | Short | 5 kD/10 bases | Centrifuge 3 minutes at 1000xG |
Clarion™ 96 Gel_Filtration Plate 1000 μL Well Volume | |||||||||
802007 | 96 | 1000 µL | 38 mm | 40 µL | 650 µL | S50-SF | Long | 25 kD/20 bases | Centrifuge 3 minutes at 1000xG |
Hi-Tech Automation formed by Ricky Thompson and Gary Probert in 1996, which created for the first……...
K-Tek International is a global marketing company that has partnered with world-wide companies to……...
The FL500 UV/IR Flame Detector is compact and enables rapid flame detection with enhanced resista……...
J.F.D. Tube & Coil Products, Inc. was founded in September, 1983. The company started in a 15……...
The NPS-X-15A nanoposition system has been specifically designed for high speed, ultra precision ……...
MR SOLUTIONS is a world leader in MRI technology.We are a leading developer and manufacturer of t……...
A/D Fire Protection Systems' quality goal is to cost effectively manufacture passive fire protection materials that meet or exceed regulatory requirements and the expectations of our customers……
Allegheny Bradford Corporation is a Pennsylvania corporation with three operating divisions—Allegheny Bradford, Top Line Process Equipment Company, and Allegheny Surface Technology—whic……
Video credit: Thermo Fisher Scientific Using the Thermo Scientific™MarqMetrix™All-in-One Process Raman Analyzer, organizations have the ability to perform instantaneous, non-invasive a……