National Photocolor Corporation
National Photocolor Corporation is a manufacturer of off-the-shelf and custom pellicles. We offer……...
Ion mobility is a powerful extension to mass spectrometry that delivers information about the three dimensional structure of an ion, and increases peak capacity and confidence in compound characterization.
timsTOF was engineered by Bruker experts as an open platform to accelerate the adoption of ion mobility-mass spectrometry analysis across research applications.
Are your analyses blind to some compounds, like structural isomers?
Does trying to resolve overlapping fragment ion spectra give you a headache?
Is your mass spectrometer as flexible as you need for everyday challenges in the lab?
All That is Missing Are Your Expertise and Curiosity.
Bruker’s timsTOF - Flexibility to empower your ideas
Flexibility - View Samples the Way You Want
With the flip of a switch, augment the peak capacity of your analytical system beyond chromatography and time-of-flight separation. No penalty in analysis time, no penalty in sensitivity.
timsTOF features adjustable ion mobility separation based on Trapped Ion Mobility Spectrometry (TIMS), so you can explore samples in various and meaningful ways. Furthermore, timsTOF uses an open data format (*.tdf) that introduces full transparency, efficiency and flexibility into your data analysis strategy.
Resolution - More Control, More Answers
timsTOF combines high ion mobility resolution with ultra-high resolution QTOF technology for optimal performance. imeXTM technology further boosts the functionality by making ion mobility resolution an adjustable parameter.
Investigate your sample in imeX survey mode for mobility-resolved full scans, and then extend your workflow with a detailed examination of selected compounds and precise collisional cross sections (CCS). Increase ion mobility resolution up to 200 for unique insights into your samples in imeX ultra mode.
Confidence - Expand What You Know about a Compound
Confident identification of compounds is based on orthogonal qualifiers that are reliably reported with high accuracy. With timsTOF, exact mass measurements (low ppm) are complemented with Bruker’s unique isotopic pattern fidelity (True Isotopic Pattern or TIPTM) and precise collisional cross section determination (<0.5% RSD).
Instrument geometry and the positioning of ion mobility separation prior to quadrupole isolation and fragmentation generate clear fragmentation spectra to further enhance certainty of identifications.
For Research Use Only. Not for Use in Clinical Diagnostic Procedures.
Flexibility - View samples the way you want - Picture 1
Flexibility - View samples the way you want - Picture 2
Confidence - Expand what you know about a compound
National Photocolor Corporation is a manufacturer of off-the-shelf and custom pellicles. We offer……...
REUZEit® brings value to the biotech and pharmaceutical industry for over 20 years, and as we……...
The National Institute for Materials Science, or NIMS, was established with the overall purpose o……...
Atomfab from Oxford Instruments offers quick, low damage, low CoO production plasma ALD processin……...
The pharmaceutical sector has developed alternative drying techniques. However, vacuum tray dryin……...
NANOX® is a company that develops, produces and markets solutions for the nanotechnology indu……...
Established in 1991, the Institute of Microelectronics (IME) is a research institute under Singapore’s Agency for Science, Technology and Research (A*STAR). In IME, we focus on delivering hig……
Micropol is based in Stalybridge, Cheshire and has over 30 years experience in polymers. Out technical expertise is world class and out customers world wide. Our extensive in-house facilities allow……
RAS Process Equipment , was established in 1977 and is committed to the design, engineering and manufacturing of quality process equipment for our customers. Equipment can be manufactured to the AS……