The VT Beetle from RHK is the most thermally and mechanically stable of the many SPM designs with varying temperature that are currently available on the market. The system includes broad VT operation ranging between 25 K (LHe) and 1500 K, which is coupled with easy to align AFM, enabling a complete range of methods from advanced NC-AFM to true quantitative friction force measurements.
It is easy for users to switch between AFM and STM in UHV, and switch and store tips, samples and probes in UHV. RHK’s exceptional electromagnet design provides a reversible and constantly varying field up to 1 Tesla in plane with a sample size measuring 1 cm. Resolution, stability, drift, or vibration isolation is not compromised. The field can be adjusted in real-time, and the probe does not need to be retracted from the sample for imaging.
Specifications
The specifications of the Beetle UHV VT VMF are as follows:
Smart design consisting of ex-vacuum convectional electromagnets do not require cooling and offer constantly reversible and varying fields
Beetle design scans more rapidly when compared to sample scanners owing to less limitations on resonant frequency
Strong field of up to 1T magnetic field in sample plane
Easy to use on a daily basis without frustration of others’ highly complex and less intuitive approach
Coarse XY positioning at least 5 mm x 5 mm
Inherent thermal and mechanical stability owing to minute thermal and mechanical loop, innately compact and rigid Beetle design, and symmetrical geometry
Thermal drift <1 Å/minute
Sample temperatures at the time of imaging are 1000 K for STM and 750 K for AFM
Heating samples does not impact on scan tube, thus preventing the risk of affecting its thermal coefficient and causing drift
Sample holders also offered for delivering RF signal to sample, cleaving, and heating in reactive gases through ceramic button or quartz bulb
Sample size is of 10 mm diameter
Optional out of plane magnetic field is available.
Sample temperatures range from 25 K (LHe) to >1500 K; or 100 K (LN2) to >1500 K
Minimum resolution of 0.5Å (X, Y) and 0.1Å (Z)
Beetle sample holder exceptionally offers accurate and true sample temperature measurement through thermocouple in direct contact with sample itself
Sample temperatures from 25 K to >1500 K on manipulator stages and on SPM sample stage in preparation/analysis chambers
6 electrical contacts to sample holder (2 for heating, 2 for temperature, 2 for auxiliary use such as BEEM). A particular holder easily supports all cooling and heating modes –e-beam, radiative, resistive/DC; LHe and LN2
Scan range of at least 5 µ x 5 µ XY
Third Dimension develops and sells 3D measurement products that meet clear needs in selected indu……...
Schäfter+Kirchhoff was first established about 50 years ago as an optical engineering office……...
The three managing partners and the staff of over 80 at FOSTAG Formenbau AG are all highly commit……...
Over 30 years of innovation Incorporated in 1972, Chiu Technical has been a private label manufac……...
Testometric has introduced a twin column, heavy duty, floor standing Universal Testing Machine c……...
HÜBNER Photonics is an international organization with offices in Stockholm, Sweden (Cobolt ……...
Established in 1991, the Institute of Microelectronics (IME) is a research institute under Singapore’s Agency for Science, Technology and Research (A*STAR). In IME, we focus on delivering hig……
Micropol is based in Stalybridge, Cheshire and has over 30 years experience in polymers. Out technical expertise is world class and out customers world wide. Our extensive in-house facilities allow……
RAS Process Equipment , was established in 1977 and is committed to the design, engineering and manufacturing of quality process equipment for our customers. Equipment can be manufactured to the AS……