AvaSpec-NEXOS™: The Next Generation Photonics Spectrometer

上海仪舶实验室自动化 25-01-23 12:58:04

AvaSpec-NEXOS™: The Next Generation Photonics Spectrometer

The NEXOSTM is a next-generation photonics backbone spectrometerenhancing numerous applications across multiple sectors. The most recent automation techniques from Avantes are used in the production of this device to guarantee excellent inter-instrument repeatability.

Compact Size, Limitless Possibilities

The powerful and lightweight NEXOSTM spectrometer from Avantes provides top-notch performance for spectroscopy integration. With integration durations of up to 9 μs, minimum stray light as low as 0.1%, and an excellent signal-to-noise ratio of 375:1, the spectrometer offers high-speed performance.Avantes light sources, accessories, and AvaSoft software are all compatible with the NEXOSTM, allowing customers to tailor their setups to specific measuring needs.

This robust and adaptable spectrometer featuresUSB2 connectivity. There are additional communication protocols (such RS232/SPI) that are tailored for Original Equipment Manufacturer (OEM) uses.

With over 15 types of gratings and six slit diameters, this device can be tailorored to exact specifications. For non-OEM products, the replacement slit option is standard.

Thespectroscopic device can be used in conjunction with Software Development Kits (AvaSoft) and is ideal for OEM applications.

Avantes can create large quantities of the NEXOSTM spectrometer with exceptional accuracy and repeatability at a faster efficiency rate due to the manufacturing process's automation.

Product Variations

Avantes also introduces the NEXOSTM-Link and NEXOSTM-Bench Only in addition to the USB-powered NEXOSTM. For OEM clients, the Link version provides alternative communication protocols (RS232 or SPI). The Bench Only version is designed for easyimplementation on either the Avantes AS7010 electronic board or the customer's own electronic board.

AvaSpec-NEXOS™: The Next Generation Photonics Spectrometer

Image Credit: Avantes

Product Information

Technical Data

Source: Avantes

NEXOS™ 2K NEXOS™ 4K
Optical bench Symmetrical Czerny-Turner, 75 mm focal length; spectrometer bench Symmetrical Czerny-Turner, 75 mm focal length; spectrometer bench
Wavelength range 190-1100 nm 190-1100 nm
Stray light 0.1-1% (typical value 300 l/mm, blaze 300 nm < 0.3%) 0.1-1% (typical value 300 l/mm, blaze 300 nm < 0.3%)
Detector HAM S11639, CMOS linear array, 2048 pixels (14 x 200 µm) HAM S13496, CMOS linear array, 4096 pixels (7×200 µm)
Signal/noise 375:1 365:1
Dynamic Range 4500 4500
Dark noise 15 cnts 15 cnts
AD converter 16 bit, 6 MHz 16 bit, 6 MHz
Integration time 9 µs-30 sec 9 µs-30 sec
Interface USB 2.0 (480 Mbps), pigtailed (38 cm) USB-A USB 2.0 (480 Mbps), pigtailed (38 cm) USB-A
Sample speed with on-board averaging 0.36 ms/scan 0.70 ms/scan
Data transfer speed 0.79 ms/scan 1.12 ms/scan
Digital I/O 5 bidirectional programmable I/O; 1 Analog out, 1 Analog in, 1x5 V 5 bidirectional programmable I/O; 1 Analog out, 1 Analog in, 1x5 V
Power supply Default USB power, 500 mA Default USB power, 500 mA
Dimensions, weight 105 x 80x 20 mm, 277,5 grams 105 x 80x 20 mm, 277,5 grams
Operating temperature range 5-55 °C 5-55 °C

Gratings

Source: Avantes

Use Useable range (nm) Spectral range (nm) Lines/mm Blaze (nm) Order code
UV/VIS/NIR 190-1100** 910** 300 300 MN0300-0.30
UV/VIS 190-780 544-540* 600 300 MN0600-0.30
UV 190-532 261-256* 1200 250 MN1200-0.25
UV 190-472 168-152* 1800 UV MN1800-0.25
UV 190-423 121-103* 2400 UV MN2400-0.25
UV 190-337 72-57* 3600 UV MN3600-0.25
UV/VIS 280-852 536-532* 600 400 MN0600-0.40
VIS/NIR 300-1100** 800** 300 500 MN0300-0.50
VIS 350-959 529-519* 600 500 MN0600-0.50
VIS 320-776 247-216* 1200 500 MN1200-0.50
VIS 360-641 147-121* 1800 500 MN1800-0.50
VIS 360-489 96-89* 2400 VIS MN2400-0.50
NIR 480-1066 515-506* 600 750 MN0600-0.75
NIR 600-844 210-204* 1200 750 MN1200-0.75
NIR 600-1100 339-300* 830 800 MN0830-0.80
NIR 600-1100** 500** 300 1000 MN0300-1.00
NIR 600-1100 500 600 1000 MN0600-1.00

A selected set of possible start-stop ranges apply. Please contact us to discuss your options. * Depends on the starting wavelength of the grating; the higher the wavelength, the bigger the dispersion and smaller the range to select ** Please note that not all pixels will be used for the useable range

Resolution

Source: Avantes

Slit size (µm) 10 25 50 100 200 500
2K resolution
300 lines/mm grating 1.0 1.4 2.25 4.8 9.2 21.3
600 lines/mm grating 0.40-0.53* 0.7 1.2 2.4 4.6 10.8
830 lines/mm grating 0.32 0.48 0.93 1.7 3.4 8.5
1200 lines/mm grating 0.20-0.28* 0.27-0.38* 0.52-0.66* 1.1 2.3 5.4
1800 lines/mm grating 0.10-0.18* 0.20-0.29* 0.34-0.42* 0.8 1.6 3.6
2400 lines/mm grating 0.09-0.13* 0.13-0.17* 0.26-0.34* 0.44-0.64* 1.1 2.7
3600 lines/mm grating 0.06-0.08* 0.10 0.19 0.4 0.8 1.8
4K resolution
300 lines/mm grating 0.50-0.70 1.4 2.25 4.8 9.2 21.3
600 lines/mm grating 0.30-0.36* 0.7 1.2 2.4 4.6 10.8
830 lines/mm grating 0.25 0.48 0.93 1.7 3.4 8.5
1200 lines/mm grating 0.14-0.18* 0.27-0.38* 0.52-0.66* 1.1 2.3 5.4
1800 lines/mm grating 0.09-0.11* 0.20-0.29* 0.34-0.42* 0.8 1.6 3.6
2400 lines/mm grating 0.07-0.09* 0.13-0.17* 0.26-0.34* 0.44-0.64* 1.1 2.7
3600 lines/mm grating 0.05-0.06* 0.10 0.19 0.4 0.8 1.8

*Depends on the starting wavelength of the grating; the higher the wavelength, the bigger the dispersion and the higher the resolution.

Ordering Information

Source: Avantes

. .
AvaSpec-NXS2048CL Compact fiber-optic spectrometer, 75 mm focal length, 2048 pixel CMOS detector, USB 2 powered interface, needs DCL, second order suppressing, replaceable slit
AvaSpec-NXS4096CL Compact fiber-optic spectrometer, 75 mm focal length, 4096 pixel CMOS detector, USB 2 powered interface, needs DCL, second order suppressing, replaceable slit
*OEM AvaSpec-NXS2048CL OEM Compact fiber-optic spectrometer, 75 mm focal length, 2048 pixel CMOS detector, USB 2 powered interface, needs DCL, second order suppressing, fixed slit
*OEM AvaSpec-NXS4096CL OEM Compact fiber-optic spectrometer, 75 mm focal length, 4096 pixel CMOS detector, USB 2 powered interface, needs DCL, second order suppressing, fixed slit

Options

Source: Avantes

. .
SLIT-XX-PRS Replaceable Slit for non OSF configurations. Slit size, please specify XX = 10, 25, 50, 100, 200, 500 µm Slit size, please specify XX = 10, 25, 50, 100, 200, 500 µm
SLIT-XX-PRSF Replaceable Slit for OSF configurations. Slit size, please specify XX = 10, 25, 50, 100, 200, 500 µm
*SLIT-XX-P Fixed Slit for NEXOS. Slit size, please specify XX = 10, 25, 50, 100, 200, 500 µm
OSC Order sorting coating for grating MN 0600-0.50
OSC-UA Order sorting coating for grating MN 0300-0.30 / MN 0300-0.50
OSC-UB Order sorting coating for grating MN 0600-0.50
OSF-YYY-3 Order sorting filter for reduction of second-order effects, please specify YYY = 305, 395, 47, 515, 550 or 600 nm,ndepends on range
DCL Detector Collection Lens. To be included

Avantes NEXOS Spectrometer - Empowering Spectroscopy Solutions

Video Credit: Avantes

* Only for OEM customers Avantes will select needed second order suppression based on desired configuration.

[AvaSpec-NEXOS™: The Next Generation Photonics Spectrometer]相关推荐
Eriez Magnetics

Eriez Magnetics

Established in 1942, Eriez is a global leader in separation technologies. Our commitment to innov……...

R M Wilson Company

R M Wilson Company

RM Wilson co. has 10 seasoned sales representatives who know the needs and challenges of their lo……...

Clariant Mining Services

Clariant Mining Services

Clariant Mining Services is a leading global supplier of chemicals and integrated services to the……...

Eagleyard Photonics GmbH

Eagleyard Photonics GmbH

eagleyard Photonics is a leading provider of high­power laser diodes with wavelengths ranging……...

Creative Woodturner

Creative Woodturner

Creative Woodturner is a fantastic addition to all woodturners toolboxes. This woodturning design……...

今日仪器
  1. Borealis AG

    Borealis AG

    For over 25 years, Borealis has been a leading provider of polyolefins, base chemicals, and fertilizers. In line with its mission to Keep Discovering, innovative solutions made possible by Borealis……

    代理品牌 2025-04-28

  2. EMCCD Cameras - iXon Series

    EMCCD Cameras - iXon Series

    The iXon EMCCD cameras from Andor are scientific digital cameras particularly designed to drive the absolute best from EMCCD technology across all performance parameters and specifications. The ult……

    仪器产品 2025-04-28

  3. Nanalysis 100e Benchtop NMR

    Nanalysis 100e Benchtop NMR

    Nanalysis’ 100e benchtop NMR works on the basis of world’s most robust compact magnet platform at 100 MHz. This single-channel spectrometer has been designed for high-performance regula……

    代理品牌 2025-04-28

返回顶部小火箭