Schut Geometrische Meettechniek b.v.
Schut Geometrical Metrology (Schut Geometrische Meettechniek bv) is an international organization……...
The Airnet II 4-Channel particle sensor simplifies cleanroom monitoring in a cost-effective manner. With its compact design, it delivers exceptional performance and has the capability to transmit data. It also complies with the ISO 21501-4 and ISO 14644-1:2015 standards.
The sensor is easy to install, offering various power options, including distributed power from an in-house system, local power sources, or Power over Ethernet (PoE).
It also supports various communication methods, including Ethernet for interfacing with Pharmaceutical Net, Facility Net, or FacilityPro® software, OPC communications, Modbus communications, or an optional 4-20 mA output.
The sensor ensures data integrity by continuing to collect data even during network disruptions, thanks to its data queue feature. Furthermore, it includes a Dynamic Flow Sensing system to guarantee consistent flow conditions and vacuum system functionality, alerting users to any 15% change in flow conditions.
Benefits
A laser diode (LD) drastically reduces the need for maintenance and extends product lifecycle
A low-cost solution for multipoint monitoring
A small footprint and flexible mounting options make it easy to install in cleanrooms and mini-environments
Allows for immediate reaction to particle contamination events
Automatic laser shutdown reduces laser failures
Data queue maintains data integrity when communication is lost
Interfaces with Facility Net, Pharmaceutical Net and FacilityPro Software for comprehensive management of cleanroom conditions
Optional 4-20 mA output for integration with existing systems to help you understand your environment
Proven technology provides reliable and accurate data
Features
0.1 and 1.0 CFM flow rate
0.2 and 10.0 µm size range
4 channels
Chemical-resistant polycarbonate (PC) enclosure
Includes system validation documentation
Interfaces with object linking and embedding (OLE) for process control (OPC) communications, Modbus communications and optional 4-20 mA output
ISO14644-1:2015 Compliant
Low sample point cost
Small enough for use in remote locations
Applications
Cleanroom monitoring
Dedicated monitoring of critical locations
Isolator monitoring
Multi-location monitoring
Statistical process control
Trend analysis
Specifications
Source: Particle Measuring Systems
201-4 | 301-4 | 310-4 | 501-4 | 510-4 | |
---|---|---|---|---|---|
Size Range (μm) | 0.2, 0.3,0.5, 1.0 | 0.3, 0.5,1.0, 5.0 | 0.3, 0.5,1.0, 5.0 | 0.5, 1.0,5.0, 10.0 | 0.5, 1.0,5.0, 10.0 |
Flow Rate | 0.1 CFM(2.8 LPM) | 0.1 CFM(2.8 LPM) | 1.0 CFM(28.3 LPM) | 0.1 CFM(2.8 LPM) | 1.0 CFM(28.3 LPM) |
Counting Efficiency | 50% ± 20% for most sensitive channel. Meets ISO 21501-4100% ± 10% at 1.5 to 2.0 times channel one size. Meets ISO 21501-4 | ||||
Zero Count | ≤ 70.7 counts/m3 | ≤ 70.7 counts/m3 | ≤ 7.07 counts/m3 | ≤ 70.7 counts/m3 | ≤ 7.07 counts/m3 |
Maximum Concentration1 | 5,057,310 /ft3 | 4,862,798 /ft3 | 702,404 /ft3 | 7,437,220 /ft3 | 890,371 /ft3 |
Laser Source | Diode | ||||
Laser Classification | Class 1 per EN60825 (Internally, a Class IIIB laser is used, per EN60825) | ||||
Exterior Surface | Polycarbonate | ||||
Dimensions(H x W x L) | 3.8 x 3.6 x 5.3 in (9.6 x 8.9 x 13.5 cm) | ||||
Weight | 1.6 lb (0.73 kg) | ||||
Sample Probe or Tubing | 1/4” ID | ||||
Flow System | External vacuum 1/4” connectionAutomatic laser shutoff and alarm on 15% flow variation | ||||
Vacuum Source | > 12 in Hg required | ||||
Power | Power over Ethernet (PoE) via PoE router (48 VDC) or PoE power injectorOptional 24 VDC (0.5 A) power input | ||||
Communication Connectors | Ethernet (Particle Measuring Systems proprietary protocol, OPC, Modbus TCP)Optional 4-20 mA (5 output channels: 4 particle data, 1 instrument status)RS-232 (configuration and diagnostic only) | ||||
Status Indicators | Programmable status (two-color LED), Activity (one-color LED) | ||||
Calibration | Calibration materials used are traceable to the National Institute for Standards and Technology (NIST)and meet ISO 21501-4 requirements | ||||
Environment | Temperature: 39 – 95 °F (4 – 35 °C)Relative humidity: 5 – 95%, non-condensing | ||||
Complies With | EU RoHS, ISO 21501-4 |
1Greater than 90% accuracy (less than 10% coincidence loss)at maximum recommended concentration.
Schut Geometrical Metrology (Schut Geometrische Meettechniek bv) is an international organization……...
Impreglon is a modern service provider, with production facilities in 10 countries, offering a wi……...
Founded in 1826 in the heart of London, UCL is London's leading multidisciplinary university……...
In support of our laser and water jet cutting capabilities, Laser Industries offers value added f……...
Norgren is part of global engineering organization IMI plc. IMI is at the forefront of delivering……...
PetrolValves is a leading manufacturer of valves for the oil and gas industry. Formed in 1956, Pe……...
Opti-Forms is a designer and manufacturer of electroformed optical reflectors, coldshields, mechanical assemblies and the application of high performance specialty thin film coatings for the commer……
Adimec designs and manufactures high-performance industrial cameras for OEM’s worldwide with demanding machine vision, medical, or military applications whose goal is to be a product leader i……
Applegate is the UK's best known and longest established internet directory for industry, manufacturing and technology in the UK and Ireland. It is the largest and most comprehensive directory……